Cargando…
Quantitative analysis of macular contraction in idiopathic epiretinal membrane
BACKGROUND: We aimed to quantify the displacement of macular capillaries using infrared fundus photographs and image processing software (ImageJ) in patients with idiopathic epiretinal membrane (ERM) who have undergone vitrectomy and to analyze the correlation between vessel displacement and retinal...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3996257/ https://www.ncbi.nlm.nih.gov/pubmed/24735324 http://dx.doi.org/10.1186/1471-2415-14-51 |
_version_ | 1782313014371811328 |
---|---|
author | Kim, Jee Wook Choi, Kyung Seek |
author_facet | Kim, Jee Wook Choi, Kyung Seek |
author_sort | Kim, Jee Wook |
collection | PubMed |
description | BACKGROUND: We aimed to quantify the displacement of macular capillaries using infrared fundus photographs and image processing software (ImageJ) in patients with idiopathic epiretinal membrane (ERM) who have undergone vitrectomy and to analyze the correlation between vessel displacement and retinal thickness. METHODS: This prospective study included 16 patients who underwent vitrectomy for idiopathic ERM. Ophthalmic examination and optical coherence tomography (OCT) were performed before and 3 months after surgery. The length of radial vessel segment included in each area (VLA) and the length from the foveola to the vessel branching point (FBL) depending on the superior, inferior, nasal, and temporal areas of the macula were measured using infrared fundus images and image processing software (ImageJ). Preoperative and postoperative parameters were compared and correlations between VLA, FBL, macular thickness, and visual acuity were assessed. RESULTS: The VLA of superior, inferior, and temporal areas showed a significant postoperative reduction. VLA differences showed a positive correlation with differences in macular thickness, which corresponded to the superior, inferior, and temporal areas; however, no correlation was observed in the nasal area. The FBL of the superior and inferior areas was significantly increased postoperatively. A positive correlation was observed between FBL differences and macular thickness differences in the superior area. Postoperative change in VLA and FBL did not show a significant correlation with postoperative best corrected visual acuity (BCVA) and BCVA differences. CONCLUSIONS: Infrared fundus photographs and image processing software can be useful for quantifying progressive changes in retinal surface distortion after surgical removal of ERM. Macular edema and vascular distortion showed significant improvement after surgery. Furthermore, a correlation was observed between topographic and tomographic changes. |
format | Online Article Text |
id | pubmed-3996257 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-39962572014-04-24 Quantitative analysis of macular contraction in idiopathic epiretinal membrane Kim, Jee Wook Choi, Kyung Seek BMC Ophthalmol Research Article BACKGROUND: We aimed to quantify the displacement of macular capillaries using infrared fundus photographs and image processing software (ImageJ) in patients with idiopathic epiretinal membrane (ERM) who have undergone vitrectomy and to analyze the correlation between vessel displacement and retinal thickness. METHODS: This prospective study included 16 patients who underwent vitrectomy for idiopathic ERM. Ophthalmic examination and optical coherence tomography (OCT) were performed before and 3 months after surgery. The length of radial vessel segment included in each area (VLA) and the length from the foveola to the vessel branching point (FBL) depending on the superior, inferior, nasal, and temporal areas of the macula were measured using infrared fundus images and image processing software (ImageJ). Preoperative and postoperative parameters were compared and correlations between VLA, FBL, macular thickness, and visual acuity were assessed. RESULTS: The VLA of superior, inferior, and temporal areas showed a significant postoperative reduction. VLA differences showed a positive correlation with differences in macular thickness, which corresponded to the superior, inferior, and temporal areas; however, no correlation was observed in the nasal area. The FBL of the superior and inferior areas was significantly increased postoperatively. A positive correlation was observed between FBL differences and macular thickness differences in the superior area. Postoperative change in VLA and FBL did not show a significant correlation with postoperative best corrected visual acuity (BCVA) and BCVA differences. CONCLUSIONS: Infrared fundus photographs and image processing software can be useful for quantifying progressive changes in retinal surface distortion after surgical removal of ERM. Macular edema and vascular distortion showed significant improvement after surgery. Furthermore, a correlation was observed between topographic and tomographic changes. BioMed Central 2014-04-16 /pmc/articles/PMC3996257/ /pubmed/24735324 http://dx.doi.org/10.1186/1471-2415-14-51 Text en Copyright © 2014 Kim and Choi; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kim, Jee Wook Choi, Kyung Seek Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title | Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title_full | Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title_fullStr | Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title_full_unstemmed | Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title_short | Quantitative analysis of macular contraction in idiopathic epiretinal membrane |
title_sort | quantitative analysis of macular contraction in idiopathic epiretinal membrane |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3996257/ https://www.ncbi.nlm.nih.gov/pubmed/24735324 http://dx.doi.org/10.1186/1471-2415-14-51 |
work_keys_str_mv | AT kimjeewook quantitativeanalysisofmacularcontractioninidiopathicepiretinalmembrane AT choikyungseek quantitativeanalysisofmacularcontractioninidiopathicepiretinalmembrane |