Cargando…

Dose Distributions of an (192)Ir Brachytherapy Source in Different Media

This study used MCNPX code to investigate the brachytherapy (192)Ir dose distributions in water, bone, and lung tissue and performed radiophotoluminescent glass dosimeter measurements to verify the obtained MCNPX results. The results showed that the dose-rate constant, radial dose function, and anis...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, C. H., Liao, Y. J., Liu, Y. W. Hsueh, Hung, S. K., Lee, M. S., Hsu, S. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3997138/
https://www.ncbi.nlm.nih.gov/pubmed/24804263
http://dx.doi.org/10.1155/2014/946213
_version_ 1782313147499020288
author Wu, C. H.
Liao, Y. J.
Liu, Y. W. Hsueh
Hung, S. K.
Lee, M. S.
Hsu, S. M.
author_facet Wu, C. H.
Liao, Y. J.
Liu, Y. W. Hsueh
Hung, S. K.
Lee, M. S.
Hsu, S. M.
author_sort Wu, C. H.
collection PubMed
description This study used MCNPX code to investigate the brachytherapy (192)Ir dose distributions in water, bone, and lung tissue and performed radiophotoluminescent glass dosimeter measurements to verify the obtained MCNPX results. The results showed that the dose-rate constant, radial dose function, and anisotropy function in water were highly consistent with data in the literature. However, the lung dose near the source would be overestimated by up to 12%, if the lung tissue is assumed to be water, and, hence, if a tumor is located in the lung, the tumor dose will be overestimated, if the material density is not taken into consideration. In contrast, the lung dose far from the source would be underestimated by up to 30%. Radial dose functions were found to depend not only on the phantom size but also on the material density. The phantom size affects the radial dose function in bone more than those in the other tissues. On the other hand, the anisotropy function in lung tissue was not dependent on the radial distance. Our simulation results could represent valid clinical reference data and be used to improve the accuracy of the doses delivered during brachytherapy applied to patients with lung cancer.
format Online
Article
Text
id pubmed-3997138
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39971382014-05-06 Dose Distributions of an (192)Ir Brachytherapy Source in Different Media Wu, C. H. Liao, Y. J. Liu, Y. W. Hsueh Hung, S. K. Lee, M. S. Hsu, S. M. Biomed Res Int Research Article This study used MCNPX code to investigate the brachytherapy (192)Ir dose distributions in water, bone, and lung tissue and performed radiophotoluminescent glass dosimeter measurements to verify the obtained MCNPX results. The results showed that the dose-rate constant, radial dose function, and anisotropy function in water were highly consistent with data in the literature. However, the lung dose near the source would be overestimated by up to 12%, if the lung tissue is assumed to be water, and, hence, if a tumor is located in the lung, the tumor dose will be overestimated, if the material density is not taken into consideration. In contrast, the lung dose far from the source would be underestimated by up to 30%. Radial dose functions were found to depend not only on the phantom size but also on the material density. The phantom size affects the radial dose function in bone more than those in the other tissues. On the other hand, the anisotropy function in lung tissue was not dependent on the radial distance. Our simulation results could represent valid clinical reference data and be used to improve the accuracy of the doses delivered during brachytherapy applied to patients with lung cancer. Hindawi Publishing Corporation 2014 2014-04-07 /pmc/articles/PMC3997138/ /pubmed/24804263 http://dx.doi.org/10.1155/2014/946213 Text en Copyright © 2014 C. H. Wu et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wu, C. H.
Liao, Y. J.
Liu, Y. W. Hsueh
Hung, S. K.
Lee, M. S.
Hsu, S. M.
Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title_full Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title_fullStr Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title_full_unstemmed Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title_short Dose Distributions of an (192)Ir Brachytherapy Source in Different Media
title_sort dose distributions of an (192)ir brachytherapy source in different media
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3997138/
https://www.ncbi.nlm.nih.gov/pubmed/24804263
http://dx.doi.org/10.1155/2014/946213
work_keys_str_mv AT wuch dosedistributionsofan192irbrachytherapysourceindifferentmedia
AT liaoyj dosedistributionsofan192irbrachytherapysourceindifferentmedia
AT liuywhsueh dosedistributionsofan192irbrachytherapysourceindifferentmedia
AT hungsk dosedistributionsofan192irbrachytherapysourceindifferentmedia
AT leems dosedistributionsofan192irbrachytherapysourceindifferentmedia
AT hsusm dosedistributionsofan192irbrachytherapysourceindifferentmedia