Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

BACKGROUND: Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. OBJECTIVE: To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end...

Descripción completa

Detalles Bibliográficos
Autores principales: Macedo, Robson, Fernandes, Juliano Lara, Andrade, Solange Souza, Rochitte, Carlos Eduardo, Lima, Kênio Costa, Maciel, Álvaro Campos Cavalcanti, Maciel, Fernanda Cunha, Alves, Geraldo Souza Pinho, Coelho, Otávio Rizzi, Diniz, Rosiane Viana Zuza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Cardiologia 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3998183/
https://www.ncbi.nlm.nih.gov/pubmed/23752338
http://dx.doi.org/10.5935/abc.20130113
Descripción
Sumario:BACKGROUND: Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. OBJECTIVE: To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. METHODS: 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. RESULTS: The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. CONCLUSION: This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.