Cargando…
Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples
BACKGROUND: We evaluated the analytical and clinical performances of the SD BIOLINE Rota/Adeno Rapid kit (SD Rota/Adeno Rapid; Standard Diagnostics, Inc., Korea), an immunochromatographic assay (ICA), for the simultaneous detection of rotaviruses and adenoviruses in human stool samples. METHODS: We...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3999320/ https://www.ncbi.nlm.nih.gov/pubmed/24790909 http://dx.doi.org/10.3343/alm.2014.34.3.216 |
_version_ | 1782313483050680320 |
---|---|
author | Kim, Jayoung Kim, Hyun Soo Kim, Han-Sung Kim, Jae-Seok Song, Wonkeun Lee, Kyu Man Lee, Sunhwa Park, Kyoung Un Lee, Woochang Hong, Young Jun |
author_facet | Kim, Jayoung Kim, Hyun Soo Kim, Han-Sung Kim, Jae-Seok Song, Wonkeun Lee, Kyu Man Lee, Sunhwa Park, Kyoung Un Lee, Woochang Hong, Young Jun |
author_sort | Kim, Jayoung |
collection | PubMed |
description | BACKGROUND: We evaluated the analytical and clinical performances of the SD BIOLINE Rota/Adeno Rapid kit (SD Rota/Adeno Rapid; Standard Diagnostics, Inc., Korea), an immunochromatographic assay (ICA), for the simultaneous detection of rotaviruses and adenoviruses in human stool samples. METHODS: We tested 400 clinical stool samples from patients with acute gastroenteritis and compared the ICA results with the results obtained by using ELISA, enzyme-linked fluorescent assays (ELFA), PCR, and multiplex reverse transcription-PCR (mRT-PCR). To assess the analytical performance of the SD BIOLINE Rota/Adeno Rapid kit, we determined its detection limit, reproducibility, cross-reactivity, and analytical reactivity for adenovirus subtypes, and performed interference studies. RESULTS: The overall agreement rates among the tested methods were 91.5% for rotavirus and 85.5% for adenovirus. On the basis of mRT-PCR, the overall agreement, positive agreement, and negative agreement rates of the ICA were 95.6%, 100%, and 94.9% for rotavirus, and 94.0%, 71.4%, and 94.8% for adenovirus, respectively. Using the ICA, we detected all the subtypes of adenovirus tested, but the analytical reactivities for adenovirus subtypes were different between the 4 adenovirus detection methods. The high reproducibility was confirmed, and no cross-reactivity or interference was detected. CONCLUSIONS: The SD BIOLINE Rota/Adeno Rapid kit showed acceptable analytical and clinical performances. However, interpretation of adenovirus positive/negative result should be cautious because of different detectability for adenovirus subtypes among adenovirus detection methods. |
format | Online Article Text |
id | pubmed-3999320 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-39993202014-05-01 Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples Kim, Jayoung Kim, Hyun Soo Kim, Han-Sung Kim, Jae-Seok Song, Wonkeun Lee, Kyu Man Lee, Sunhwa Park, Kyoung Un Lee, Woochang Hong, Young Jun Ann Lab Med Original Article BACKGROUND: We evaluated the analytical and clinical performances of the SD BIOLINE Rota/Adeno Rapid kit (SD Rota/Adeno Rapid; Standard Diagnostics, Inc., Korea), an immunochromatographic assay (ICA), for the simultaneous detection of rotaviruses and adenoviruses in human stool samples. METHODS: We tested 400 clinical stool samples from patients with acute gastroenteritis and compared the ICA results with the results obtained by using ELISA, enzyme-linked fluorescent assays (ELFA), PCR, and multiplex reverse transcription-PCR (mRT-PCR). To assess the analytical performance of the SD BIOLINE Rota/Adeno Rapid kit, we determined its detection limit, reproducibility, cross-reactivity, and analytical reactivity for adenovirus subtypes, and performed interference studies. RESULTS: The overall agreement rates among the tested methods were 91.5% for rotavirus and 85.5% for adenovirus. On the basis of mRT-PCR, the overall agreement, positive agreement, and negative agreement rates of the ICA were 95.6%, 100%, and 94.9% for rotavirus, and 94.0%, 71.4%, and 94.8% for adenovirus, respectively. Using the ICA, we detected all the subtypes of adenovirus tested, but the analytical reactivities for adenovirus subtypes were different between the 4 adenovirus detection methods. The high reproducibility was confirmed, and no cross-reactivity or interference was detected. CONCLUSIONS: The SD BIOLINE Rota/Adeno Rapid kit showed acceptable analytical and clinical performances. However, interpretation of adenovirus positive/negative result should be cautious because of different detectability for adenovirus subtypes among adenovirus detection methods. The Korean Society for Laboratory Medicine 2014-05 2014-04-08 /pmc/articles/PMC3999320/ /pubmed/24790909 http://dx.doi.org/10.3343/alm.2014.34.3.216 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Jayoung Kim, Hyun Soo Kim, Han-Sung Kim, Jae-Seok Song, Wonkeun Lee, Kyu Man Lee, Sunhwa Park, Kyoung Un Lee, Woochang Hong, Young Jun Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title | Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title_full | Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title_fullStr | Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title_full_unstemmed | Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title_short | Evaluation of an Immunochromatographic Assay for the Rapid and Simultaneous Detection of Rotavirus and Adenovirus in Stool Samples |
title_sort | evaluation of an immunochromatographic assay for the rapid and simultaneous detection of rotavirus and adenovirus in stool samples |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3999320/ https://www.ncbi.nlm.nih.gov/pubmed/24790909 http://dx.doi.org/10.3343/alm.2014.34.3.216 |
work_keys_str_mv | AT kimjayoung evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT kimhyunsoo evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT kimhansung evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT kimjaeseok evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT songwonkeun evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT leekyuman evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT leesunhwa evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT parkkyoungun evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT leewoochang evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples AT hongyoungjun evaluationofanimmunochromatographicassayfortherapidandsimultaneousdetectionofrotavirusandadenovirusinstoolsamples |