Cargando…

Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography

PURPOSE: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT). METHODS: In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated ret...

Descripción completa

Detalles Bibliográficos
Autores principales: Kojima, Sachi, Inoue, Toshihiro, Kawaji, Takahiro, Tanihara, Hidenobu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000242/
https://www.ncbi.nlm.nih.gov/pubmed/24790405
http://dx.doi.org/10.2147/OPTH.S59778
_version_ 1782313602598830080
author Kojima, Sachi
Inoue, Toshihiro
Kawaji, Takahiro
Tanihara, Hidenobu
author_facet Kojima, Sachi
Inoue, Toshihiro
Kawaji, Takahiro
Tanihara, Hidenobu
author_sort Kojima, Sachi
collection PubMed
description PURPOSE: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT). METHODS: In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated retrospectively. We investigated tear fluid signs associated with filtration blebs, using 3D AS-OCT with custom software, and compared the findings of lower tear meniscus. We also analyzed postoperative intraocular pressure and the bleb parameters of filtration blebs between eyes with and without tear fluid signs. RESULTS: We found tear fluid signs associated with filtration blebs in 45 (30%) of 152 eyes. The mean postoperative intraocular pressure of the eyes with the tear fluid sign in a filtration bleb was significantly lower than that in eyes without the tear fluid sign (P<0.001). Blebs with tear fluid signs have more frequent identifiable filtration openings, greater total height, increased fluid-filled cavity height, and less wall intensity compared with blebs without these signs. CONCLUSION: We identified tear fluid signs in AS-OCT images on or along filtration blebs that depended on bleb morphology. The occurrence of these signs may be related to the presence of functional blebs, which may thereby control postoperative intraocular pressure.
format Online
Article
Text
id pubmed-4000242
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-40002422014-04-30 Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography Kojima, Sachi Inoue, Toshihiro Kawaji, Takahiro Tanihara, Hidenobu Clin Ophthalmol Original Research PURPOSE: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT). METHODS: In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated retrospectively. We investigated tear fluid signs associated with filtration blebs, using 3D AS-OCT with custom software, and compared the findings of lower tear meniscus. We also analyzed postoperative intraocular pressure and the bleb parameters of filtration blebs between eyes with and without tear fluid signs. RESULTS: We found tear fluid signs associated with filtration blebs in 45 (30%) of 152 eyes. The mean postoperative intraocular pressure of the eyes with the tear fluid sign in a filtration bleb was significantly lower than that in eyes without the tear fluid sign (P<0.001). Blebs with tear fluid signs have more frequent identifiable filtration openings, greater total height, increased fluid-filled cavity height, and less wall intensity compared with blebs without these signs. CONCLUSION: We identified tear fluid signs in AS-OCT images on or along filtration blebs that depended on bleb morphology. The occurrence of these signs may be related to the presence of functional blebs, which may thereby control postoperative intraocular pressure. Dove Medical Press 2014-04-17 /pmc/articles/PMC4000242/ /pubmed/24790405 http://dx.doi.org/10.2147/OPTH.S59778 Text en © 2014 Kojima et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Kojima, Sachi
Inoue, Toshihiro
Kawaji, Takahiro
Tanihara, Hidenobu
Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_full Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_fullStr Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_full_unstemmed Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_short Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_sort tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000242/
https://www.ncbi.nlm.nih.gov/pubmed/24790405
http://dx.doi.org/10.2147/OPTH.S59778
work_keys_str_mv AT kojimasachi tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT inouetoshihiro tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT kawajitakahiro tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT taniharahidenobu tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography