Cargando…

Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain

Introduction Functional capacity evaluation (FCE) can be used to make clinical decisions regarding fitness-for-work. During FCE the evaluator attempts to assess the amount of physical effort of the patient. The aim of this study is to analyze the reliability of physical effort determination using ob...

Descripción completa

Detalles Bibliográficos
Autores principales: Trippolini, M. A., Dijkstra, P. U., Jansen, B., Oesch, P., Geertzen, J. H. B., Reneman, M. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000417/
https://www.ncbi.nlm.nih.gov/pubmed/23975060
http://dx.doi.org/10.1007/s10926-013-9470-9
_version_ 1782313617125801984
author Trippolini, M. A.
Dijkstra, P. U.
Jansen, B.
Oesch, P.
Geertzen, J. H. B.
Reneman, M. F.
author_facet Trippolini, M. A.
Dijkstra, P. U.
Jansen, B.
Oesch, P.
Geertzen, J. H. B.
Reneman, M. F.
author_sort Trippolini, M. A.
collection PubMed
description Introduction Functional capacity evaluation (FCE) can be used to make clinical decisions regarding fitness-for-work. During FCE the evaluator attempts to assess the amount of physical effort of the patient. The aim of this study is to analyze the reliability of physical effort determination using observational criteria during FCE. Methods Twenty-one raters assessed physical effort in 18 video-recorded FCE tests independently on two occasions, 10 months apart. Physical effort was rated on a categorical four-point physical effort determination scale (P(ED)) based on the Isernhagen criteria, and a dichotomous submaximal effort determination scale (S(ED)). Cohen’s Kappa, squared weighted Kappa and % agreement were calculated. Results Kappa values for intra-rater reliability of P(ED) and S(ED) for all FCE tests were 0.49 and 0.68 respectively. Kappa values for inter-rater reliability of P(ED) for all FCE tests in the first and the second session were 0.51, and 0.72, and for S(ED) Kappa values were 0.68 and 0.77 respectively. The inter-rater reliability of P(ED) ranged from κ = 0.02 to κ = 0.99 between FCE tests. Acceptable reliability scores (κ > 0.60, agreement ≥80 %) for each FCE test were observed in 38 % of scores for P(ED) and 67 % for S(ED). On average material handling tests had a higher reliability than postural tolerance and ambulatory tests. Conclusion Dichotomous ratings of submaximal effort are more reliable than categorical criteria to determine physical effort in FCE tests. Regular education and training may improve the reliability of observational criteria for effort determination.
format Online
Article
Text
id pubmed-4000417
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-40004172014-05-07 Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain Trippolini, M. A. Dijkstra, P. U. Jansen, B. Oesch, P. Geertzen, J. H. B. Reneman, M. F. J Occup Rehabil Article Introduction Functional capacity evaluation (FCE) can be used to make clinical decisions regarding fitness-for-work. During FCE the evaluator attempts to assess the amount of physical effort of the patient. The aim of this study is to analyze the reliability of physical effort determination using observational criteria during FCE. Methods Twenty-one raters assessed physical effort in 18 video-recorded FCE tests independently on two occasions, 10 months apart. Physical effort was rated on a categorical four-point physical effort determination scale (P(ED)) based on the Isernhagen criteria, and a dichotomous submaximal effort determination scale (S(ED)). Cohen’s Kappa, squared weighted Kappa and % agreement were calculated. Results Kappa values for intra-rater reliability of P(ED) and S(ED) for all FCE tests were 0.49 and 0.68 respectively. Kappa values for inter-rater reliability of P(ED) for all FCE tests in the first and the second session were 0.51, and 0.72, and for S(ED) Kappa values were 0.68 and 0.77 respectively. The inter-rater reliability of P(ED) ranged from κ = 0.02 to κ = 0.99 between FCE tests. Acceptable reliability scores (κ > 0.60, agreement ≥80 %) for each FCE test were observed in 38 % of scores for P(ED) and 67 % for S(ED). On average material handling tests had a higher reliability than postural tolerance and ambulatory tests. Conclusion Dichotomous ratings of submaximal effort are more reliable than categorical criteria to determine physical effort in FCE tests. Regular education and training may improve the reliability of observational criteria for effort determination. Springer US 2013-08-22 2014 /pmc/articles/PMC4000417/ /pubmed/23975060 http://dx.doi.org/10.1007/s10926-013-9470-9 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Article
Trippolini, M. A.
Dijkstra, P. U.
Jansen, B.
Oesch, P.
Geertzen, J. H. B.
Reneman, M. F.
Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title_full Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title_fullStr Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title_full_unstemmed Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title_short Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain
title_sort reliability of clinician rated physical effort determination during functional capacity evaluation in patients with chronic musculoskeletal pain
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000417/
https://www.ncbi.nlm.nih.gov/pubmed/23975060
http://dx.doi.org/10.1007/s10926-013-9470-9
work_keys_str_mv AT trippolinima reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain
AT dijkstrapu reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain
AT jansenb reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain
AT oeschp reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain
AT geertzenjhb reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain
AT renemanmf reliabilityofclinicianratedphysicaleffortdeterminationduringfunctionalcapacityevaluationinpatientswithchronicmusculoskeletalpain