Cargando…

Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study

AIMS: The aim of the following study is to evaluate the change in laser fluorescence (LF) values for extracted teeth stored in different solutions over 1 year period, to give cut-off values for different storage media at different time intervals to get them at par with the in vivo conditions and to...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaul, Rudra, Kaul, Vibhuti, Farooq, Riyaz, Wazir, Nikhil Dev, Khateeb, Shafayat Ullah, Malik, Altaf H, Masoodi, Ajaz Amin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4001266/
https://www.ncbi.nlm.nih.gov/pubmed/24778506
http://dx.doi.org/10.4103/0972-0707.128043
_version_ 1782313717839429632
author Kaul, Rudra
Kaul, Vibhuti
Farooq, Riyaz
Wazir, Nikhil Dev
Khateeb, Shafayat Ullah
Malik, Altaf H
Masoodi, Ajaz Amin
author_facet Kaul, Rudra
Kaul, Vibhuti
Farooq, Riyaz
Wazir, Nikhil Dev
Khateeb, Shafayat Ullah
Malik, Altaf H
Masoodi, Ajaz Amin
author_sort Kaul, Rudra
collection PubMed
description AIMS: The aim of the following study is to evaluate the change in laser fluorescence (LF) values for extracted teeth stored in different solutions over 1 year period, to give cut-off values for different storage media at different time intervals to get them at par with the in vivo conditions and to see which medium gives best results with the least change in LF values and while enhancing the validity of DIAGNOdent in research. MATERIALS AND METHODS: Ninety extracted teeth selected, from a pool of frozen teeth, were divided into nine groups of 10 each. Specimens in Groups 1-8 were stored in 1% chloramine, 10% formalin, 10% buffered formalin, 0.02% thymol, 0.12% chlorhexidine, 3% sodium hypochlorite, a commercially available saliva substitute-Wet Mouth (ICPA Pharmaceuticals) and normal saline respectively at 4°C. The last group was stored under frozen condition at −20°C without contact with any storage solution. DIAGNOdent was used to measure the change the LF values at day 30, 45, 60, 160 and 365. STATISTICAL ANALYSIS USED: The mean change in LF values in different storage mediums at different time intervals were compared using two-way ANOVA. RESULTS: At the end of 1 year, significant decrease in fluorescence (P < 0.05) was observed in Groups 1-8. Maximum drop in LF values occurred between day 1 and 30. Group 9 (frozen specimens) did not significantly change their fluorescence response. CONCLUSIONS: An inevitable change in LF takes place due to various storage media commonly used in dental research at different time intervals. The values obtained from our study can remove the bias caused by the storage media and the values of LF thus obtained can hence be conveniently extrapolated to the in vivo condition.
format Online
Article
Text
id pubmed-4001266
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40012662014-04-28 Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study Kaul, Rudra Kaul, Vibhuti Farooq, Riyaz Wazir, Nikhil Dev Khateeb, Shafayat Ullah Malik, Altaf H Masoodi, Ajaz Amin J Conserv Dent Original Article AIMS: The aim of the following study is to evaluate the change in laser fluorescence (LF) values for extracted teeth stored in different solutions over 1 year period, to give cut-off values for different storage media at different time intervals to get them at par with the in vivo conditions and to see which medium gives best results with the least change in LF values and while enhancing the validity of DIAGNOdent in research. MATERIALS AND METHODS: Ninety extracted teeth selected, from a pool of frozen teeth, were divided into nine groups of 10 each. Specimens in Groups 1-8 were stored in 1% chloramine, 10% formalin, 10% buffered formalin, 0.02% thymol, 0.12% chlorhexidine, 3% sodium hypochlorite, a commercially available saliva substitute-Wet Mouth (ICPA Pharmaceuticals) and normal saline respectively at 4°C. The last group was stored under frozen condition at −20°C without contact with any storage solution. DIAGNOdent was used to measure the change the LF values at day 30, 45, 60, 160 and 365. STATISTICAL ANALYSIS USED: The mean change in LF values in different storage mediums at different time intervals were compared using two-way ANOVA. RESULTS: At the end of 1 year, significant decrease in fluorescence (P < 0.05) was observed in Groups 1-8. Maximum drop in LF values occurred between day 1 and 30. Group 9 (frozen specimens) did not significantly change their fluorescence response. CONCLUSIONS: An inevitable change in LF takes place due to various storage media commonly used in dental research at different time intervals. The values obtained from our study can remove the bias caused by the storage media and the values of LF thus obtained can hence be conveniently extrapolated to the in vivo condition. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4001266/ /pubmed/24778506 http://dx.doi.org/10.4103/0972-0707.128043 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kaul, Rudra
Kaul, Vibhuti
Farooq, Riyaz
Wazir, Nikhil Dev
Khateeb, Shafayat Ullah
Malik, Altaf H
Masoodi, Ajaz Amin
Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title_full Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title_fullStr Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title_full_unstemmed Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title_short Cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: A 1 year in vitro study
title_sort cut off values of laser fluorescence for different storage methods at different time intervals in comparison to frozen condition: a 1 year in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4001266/
https://www.ncbi.nlm.nih.gov/pubmed/24778506
http://dx.doi.org/10.4103/0972-0707.128043
work_keys_str_mv AT kaulrudra cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT kaulvibhuti cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT farooqriyaz cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT wazirnikhildev cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT khateebshafayatullah cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT malikaltafh cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy
AT masoodiajazamin cutoffvaluesoflaserfluorescencefordifferentstoragemethodsatdifferenttimeintervalsincomparisontofrozenconditiona1yearinvitrostudy