High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart

High‐frequency oscillatory ventilation (HFOV) may improve gas exchange in patients who are inadequately ventilated by conventional mechanical ventilation (CV); however, the hemodynamic consequences of switching to HFOV remain unclear. We compared the effects of CV and HFOV on pulmonary vascular cond...

Descripción completa

Detalles Bibliográficos
Autores principales: Smailys, Andrea, Mitchell, Jamie R., Doig, Christopher J., Tyberg, John V., Belenkie, Israel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Periodicals, Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4002239/
https://www.ncbi.nlm.nih.gov/pubmed/24760513
http://dx.doi.org/10.1002/phy2.259
_version_ 1782313790470094848
author Smailys, Andrea
Mitchell, Jamie R.
Doig, Christopher J.
Tyberg, John V.
Belenkie, Israel
author_facet Smailys, Andrea
Mitchell, Jamie R.
Doig, Christopher J.
Tyberg, John V.
Belenkie, Israel
author_sort Smailys, Andrea
collection PubMed
description High‐frequency oscillatory ventilation (HFOV) may improve gas exchange in patients who are inadequately ventilated by conventional mechanical ventilation (CV); however, the hemodynamic consequences of switching to HFOV remain unclear. We compared the effects of CV and HFOV on pulmonary vascular conductance and left ventricular (LV) preload and performance at different airway and filling pressures. In anesthetized dogs, we measured LV dimensions, aortic and pulmonary artery (PA) flow, and mean airway ([Image: see text] (AW)) and pericardial pressures. Catheter‐tip pressure manometers measured aortic, LV, left atrial, and PA pressures. The pericardium and chest were closed. At LV end‐diastolic pressure (P(LVED)) = 5 mmHg and 12 mmHg, PEEP was varied (6 cm H(2)O, 12 cm H(2)O, and 18 cm H(2)O) during CV. Then, at airway pressures equal to those during CV, HFOV was applied at 4 Hz, 10 Hz, and 15 Hz. Increased [Image: see text] (AW) decreased pulmonary vascular conductance. As cardiac output increased, conductance increased. At P(LVED )= 12 mmHg, conductance was greatest during HFOV at 4 Hz. LV preload (i.e., A(LV), our index of end‐diastolic volume) was similar during HFOV and CV for all conditions. At P(LVED )= 12 mmHg, SW(LV) was similar during CV and HFOV, but, at P(LVED )= 5 mmHg and [Image: see text] (AW) 10 cm H(2)O, SW(LV) was lower during HFOV than CV. Compared to pulmonary vascular conductance at higher frequencies, at P(LVED )= 12 mmHg, conductance was greater at HFOV of 4 Hz. Effects of CV and HFOV on LV preload and performance were similar except for decreased SW(LV) at P(LVED )= 5 mmHg. These observations suggest the need for further studies to assess their potential clinical relevance.
format Online
Article
Text
id pubmed-4002239
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Wiley Periodicals, Inc.
record_format MEDLINE/PubMed
spelling pubmed-40022392014-05-13 High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart Smailys, Andrea Mitchell, Jamie R. Doig, Christopher J. Tyberg, John V. Belenkie, Israel Physiol Rep Original Research High‐frequency oscillatory ventilation (HFOV) may improve gas exchange in patients who are inadequately ventilated by conventional mechanical ventilation (CV); however, the hemodynamic consequences of switching to HFOV remain unclear. We compared the effects of CV and HFOV on pulmonary vascular conductance and left ventricular (LV) preload and performance at different airway and filling pressures. In anesthetized dogs, we measured LV dimensions, aortic and pulmonary artery (PA) flow, and mean airway ([Image: see text] (AW)) and pericardial pressures. Catheter‐tip pressure manometers measured aortic, LV, left atrial, and PA pressures. The pericardium and chest were closed. At LV end‐diastolic pressure (P(LVED)) = 5 mmHg and 12 mmHg, PEEP was varied (6 cm H(2)O, 12 cm H(2)O, and 18 cm H(2)O) during CV. Then, at airway pressures equal to those during CV, HFOV was applied at 4 Hz, 10 Hz, and 15 Hz. Increased [Image: see text] (AW) decreased pulmonary vascular conductance. As cardiac output increased, conductance increased. At P(LVED )= 12 mmHg, conductance was greatest during HFOV at 4 Hz. LV preload (i.e., A(LV), our index of end‐diastolic volume) was similar during HFOV and CV for all conditions. At P(LVED )= 12 mmHg, SW(LV) was similar during CV and HFOV, but, at P(LVED )= 5 mmHg and [Image: see text] (AW) 10 cm H(2)O, SW(LV) was lower during HFOV than CV. Compared to pulmonary vascular conductance at higher frequencies, at P(LVED )= 12 mmHg, conductance was greater at HFOV of 4 Hz. Effects of CV and HFOV on LV preload and performance were similar except for decreased SW(LV) at P(LVED )= 5 mmHg. These observations suggest the need for further studies to assess their potential clinical relevance. Wiley Periodicals, Inc. 2014-03-26 /pmc/articles/PMC4002239/ /pubmed/24760513 http://dx.doi.org/10.1002/phy2.259 Text en © 2014 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society. http://creativecommons.org/licenses/by/3.0/ This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Smailys, Andrea
Mitchell, Jamie R.
Doig, Christopher J.
Tyberg, John V.
Belenkie, Israel
High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title_full High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title_fullStr High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title_full_unstemmed High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title_short High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
title_sort high‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4002239/
https://www.ncbi.nlm.nih.gov/pubmed/24760513
http://dx.doi.org/10.1002/phy2.259
work_keys_str_mv AT smailysandrea highfrequencyoscillatoryventilationversusconventionalventilationhemodynamiceffectsonlungandheart
AT mitchelljamier highfrequencyoscillatoryventilationversusconventionalventilationhemodynamiceffectsonlungandheart
AT doigchristopherj highfrequencyoscillatoryventilationversusconventionalventilationhemodynamiceffectsonlungandheart
AT tybergjohnv highfrequencyoscillatoryventilationversusconventionalventilationhemodynamiceffectsonlungandheart
AT belenkieisrael highfrequencyoscillatoryventilationversusconventionalventilationhemodynamiceffectsonlungandheart