Cargando…

Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation

Patients suffering from conductive or mixed hearing loss may benefit from bone-conduction hearing systems (BAHS). The amount of amplification provided by the hearing system is selected based on the individual's sensorineural frequency-specific threshold. With patients who are not able to provid...

Descripción completa

Detalles Bibliográficos
Autores principales: Rahne, Torsten, Ehelebe, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003784/
https://www.ncbi.nlm.nih.gov/pubmed/24977186
http://dx.doi.org/10.1155/2014/247942
_version_ 1782313886084497408
author Rahne, Torsten
Ehelebe, Thomas
author_facet Rahne, Torsten
Ehelebe, Thomas
author_sort Rahne, Torsten
collection PubMed
description Patients suffering from conductive or mixed hearing loss may benefit from bone-conduction hearing systems (BAHS). The amount of amplification provided by the hearing system is selected based on the individual's sensorineural frequency-specific threshold. With patients who are not able to provide thresholds behaviorally, such as young children, objective methods are required to estimate the unaided and aided hearing threshold and thus the success of the hearing system fitting. In a prospective study with ten adult Baha softband users, aided and unaided frequency-specific thresholds were estimated. Aided thresholds to tone bursts via Baha stimulation were obtained behaviorally and electrophysiologically using cortical auditory evoked potentials (CAEPs) and were compared to pure-tone thresholds using routine clinical audiometry. For all stimulation frequencies, the frequency-specific electrophysiological and behavioral hearing thresholds measured with Baha stimulation were highly correlated and not different. Increased thresholds were observed only with the 0.5 kHz Baha stimulation as compared to the pure-tone audiogram. Objective measurement of frequency-specific hearing thresholds with CAEPs is applicable to BAHS users.
format Online
Article
Text
id pubmed-4003784
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40037842014-06-29 Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation Rahne, Torsten Ehelebe, Thomas ScientificWorldJournal Research Article Patients suffering from conductive or mixed hearing loss may benefit from bone-conduction hearing systems (BAHS). The amount of amplification provided by the hearing system is selected based on the individual's sensorineural frequency-specific threshold. With patients who are not able to provide thresholds behaviorally, such as young children, objective methods are required to estimate the unaided and aided hearing threshold and thus the success of the hearing system fitting. In a prospective study with ten adult Baha softband users, aided and unaided frequency-specific thresholds were estimated. Aided thresholds to tone bursts via Baha stimulation were obtained behaviorally and electrophysiologically using cortical auditory evoked potentials (CAEPs) and were compared to pure-tone thresholds using routine clinical audiometry. For all stimulation frequencies, the frequency-specific electrophysiological and behavioral hearing thresholds measured with Baha stimulation were highly correlated and not different. Increased thresholds were observed only with the 0.5 kHz Baha stimulation as compared to the pure-tone audiogram. Objective measurement of frequency-specific hearing thresholds with CAEPs is applicable to BAHS users. Hindawi Publishing Corporation 2014 2014-04-10 /pmc/articles/PMC4003784/ /pubmed/24977186 http://dx.doi.org/10.1155/2014/247942 Text en Copyright © 2014 T. Rahne and T. Ehelebe. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Rahne, Torsten
Ehelebe, Thomas
Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title_full Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title_fullStr Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title_full_unstemmed Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title_short Objective Estimation of Frequency-Specific Pure-Tone Hearing Thresholds following Bone-Conduction Hearing Aid Stimulation
title_sort objective estimation of frequency-specific pure-tone hearing thresholds following bone-conduction hearing aid stimulation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003784/
https://www.ncbi.nlm.nih.gov/pubmed/24977186
http://dx.doi.org/10.1155/2014/247942
work_keys_str_mv AT rahnetorsten objectiveestimationoffrequencyspecificpuretonehearingthresholdsfollowingboneconductionhearingaidstimulation
AT ehelebethomas objectiveestimationoffrequencyspecificpuretonehearingthresholdsfollowingboneconductionhearingaidstimulation