Cargando…

DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases

In this study, a device based on patient motion capture is developed for the reliable and non-invasive diagnosis of neurodegenerative diseases. The primary objective of this study is the classification of differential diagnosis between Parkinson's disease (PD) and essential tremor (ET). The DIM...

Descripción completa

Detalles Bibliográficos
Autores principales: González, Roberto, Barrientos, Antonio, del Cerro, Jaime, Coca, Benito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003956/
https://www.ncbi.nlm.nih.gov/pubmed/24608001
http://dx.doi.org/10.3390/s140304536
_version_ 1782313912947965952
author González, Roberto
Barrientos, Antonio
del Cerro, Jaime
Coca, Benito
author_facet González, Roberto
Barrientos, Antonio
del Cerro, Jaime
Coca, Benito
author_sort González, Roberto
collection PubMed
description In this study, a device based on patient motion capture is developed for the reliable and non-invasive diagnosis of neurodegenerative diseases. The primary objective of this study is the classification of differential diagnosis between Parkinson's disease (PD) and essential tremor (ET). The DIMETER system has been used in the diagnoses of a significant number of patients at two medical centers in Spain. Research studies on classification have primarily focused on the use of well-known and reliable diagnosis criteria developed by qualified personnel. Here, we first present a literature review of the methods used to detect and evaluate tremor; then, we describe the DIMETER device in terms of the software and hardware used and the battery of tests developed to obtain the best diagnoses. All of the tests are classified and described in terms of the characteristics of the data obtained. A list of parameters obtained from the tests is provided, and the results obtained using multilayer perceptron (MLP) neural networks are presented and analyzed.
format Online
Article
Text
id pubmed-4003956
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-40039562014-04-29 DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases González, Roberto Barrientos, Antonio del Cerro, Jaime Coca, Benito Sensors (Basel) Article In this study, a device based on patient motion capture is developed for the reliable and non-invasive diagnosis of neurodegenerative diseases. The primary objective of this study is the classification of differential diagnosis between Parkinson's disease (PD) and essential tremor (ET). The DIMETER system has been used in the diagnoses of a significant number of patients at two medical centers in Spain. Research studies on classification have primarily focused on the use of well-known and reliable diagnosis criteria developed by qualified personnel. Here, we first present a literature review of the methods used to detect and evaluate tremor; then, we describe the DIMETER device in terms of the software and hardware used and the battery of tests developed to obtain the best diagnoses. All of the tests are classified and described in terms of the characteristics of the data obtained. A list of parameters obtained from the tests is provided, and the results obtained using multilayer perceptron (MLP) neural networks are presented and analyzed. MDPI 2014-03-07 /pmc/articles/PMC4003956/ /pubmed/24608001 http://dx.doi.org/10.3390/s140304536 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
González, Roberto
Barrientos, Antonio
del Cerro, Jaime
Coca, Benito
DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title_full DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title_fullStr DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title_full_unstemmed DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title_short DIMETER: A Haptic Master Device for Tremor Diagnosis in Neurodegenerative Diseases
title_sort dimeter: a haptic master device for tremor diagnosis in neurodegenerative diseases
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003956/
https://www.ncbi.nlm.nih.gov/pubmed/24608001
http://dx.doi.org/10.3390/s140304536
work_keys_str_mv AT gonzalezroberto dimeterahapticmasterdevicefortremordiagnosisinneurodegenerativediseases
AT barrientosantonio dimeterahapticmasterdevicefortremordiagnosisinneurodegenerativediseases
AT delcerrojaime dimeterahapticmasterdevicefortremordiagnosisinneurodegenerativediseases
AT cocabenito dimeterahapticmasterdevicefortremordiagnosisinneurodegenerativediseases