Cargando…

A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors

In this study, a polarization-control setup for intensity-resolved guided mode resonance sensors is proposed and demonstrated experimentally. The experimental results are in good agreement with the simulation data based on rigorous coupled wave approach calculations. The proposed intensity-resolved...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Sheng-Fu, Chang, Fu-Chen, Chen, Zhi-Heng, Wang, Chih-Ming, Yang, Tsung-Hsun, Chen, Wen-Yih, Chang, Jenq-Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003988/
https://www.ncbi.nlm.nih.gov/pubmed/24625743
http://dx.doi.org/10.3390/s140305198
_version_ 1782313920264929280
author Lin, Sheng-Fu
Chang, Fu-Chen
Chen, Zhi-Heng
Wang, Chih-Ming
Yang, Tsung-Hsun
Chen, Wen-Yih
Chang, Jenq-Yang
author_facet Lin, Sheng-Fu
Chang, Fu-Chen
Chen, Zhi-Heng
Wang, Chih-Ming
Yang, Tsung-Hsun
Chen, Wen-Yih
Chang, Jenq-Yang
author_sort Lin, Sheng-Fu
collection PubMed
description In this study, a polarization-control setup for intensity-resolved guided mode resonance sensors is proposed and demonstrated experimentally. The experimental results are in good agreement with the simulation data based on rigorous coupled wave approach calculations. The proposed intensity-resolved measurement setup transfers polarization ellipses, which are produced from guided mode resonance to a linear polarization state under a buffer solution condition, and then suppresses the signals to dark using a polarization-control set. Hence, any changes in the refractive index results in an increase in the intensity signals. Furthermore, no wavelength-resolved or angular-resolved measurement is needed in this scheme. According to the experimental results, a wide linear detection range of 0.014 refractive index units is achieved and the limit of detection is 1.62E-4 RIU.
format Online
Article
Text
id pubmed-4003988
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-40039882014-04-29 A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors Lin, Sheng-Fu Chang, Fu-Chen Chen, Zhi-Heng Wang, Chih-Ming Yang, Tsung-Hsun Chen, Wen-Yih Chang, Jenq-Yang Sensors (Basel) Communication In this study, a polarization-control setup for intensity-resolved guided mode resonance sensors is proposed and demonstrated experimentally. The experimental results are in good agreement with the simulation data based on rigorous coupled wave approach calculations. The proposed intensity-resolved measurement setup transfers polarization ellipses, which are produced from guided mode resonance to a linear polarization state under a buffer solution condition, and then suppresses the signals to dark using a polarization-control set. Hence, any changes in the refractive index results in an increase in the intensity signals. Furthermore, no wavelength-resolved or angular-resolved measurement is needed in this scheme. According to the experimental results, a wide linear detection range of 0.014 refractive index units is achieved and the limit of detection is 1.62E-4 RIU. MDPI 2014-03-12 /pmc/articles/PMC4003988/ /pubmed/24625743 http://dx.doi.org/10.3390/s140305198 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Communication
Lin, Sheng-Fu
Chang, Fu-Chen
Chen, Zhi-Heng
Wang, Chih-Ming
Yang, Tsung-Hsun
Chen, Wen-Yih
Chang, Jenq-Yang
A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title_full A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title_fullStr A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title_full_unstemmed A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title_short A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
title_sort polarization control system for intensity-resolved guided mode resonance sensors
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003988/
https://www.ncbi.nlm.nih.gov/pubmed/24625743
http://dx.doi.org/10.3390/s140305198
work_keys_str_mv AT linshengfu apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT changfuchen apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT chenzhiheng apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT wangchihming apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT yangtsunghsun apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT chenwenyih apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT changjenqyang apolarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT linshengfu polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT changfuchen polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT chenzhiheng polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT wangchihming polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT yangtsunghsun polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT chenwenyih polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors
AT changjenqyang polarizationcontrolsystemforintensityresolvedguidedmoderesonancesensors