Cargando…

Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis

[Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Pullagurla, Swathi R., Witek, Małgorzata A., Jackson, Joshua M., Lindell, Maria A. M., Hupert, Mateusz L., Nesterova, Irina V., Baird, Alison E., Soper, Steven A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4004188/
https://www.ncbi.nlm.nih.gov/pubmed/24650222
http://dx.doi.org/10.1021/ac5007766
_version_ 1782313943553802240
author Pullagurla, Swathi R.
Witek, Małgorzata A.
Jackson, Joshua M.
Lindell, Maria A. M.
Hupert, Mateusz L.
Nesterova, Irina V.
Baird, Alison E.
Soper, Steven A.
author_facet Pullagurla, Swathi R.
Witek, Małgorzata A.
Jackson, Joshua M.
Lindell, Maria A. M.
Hupert, Mateusz L.
Nesterova, Irina V.
Baird, Alison E.
Soper, Steven A.
author_sort Pullagurla, Swathi R.
collection PubMed
description [Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device consisted of four independent selection beds with curvilinear channels that were 25 μm wide and 80 μm deep and were modified with antibodies targeting antigens specifically expressed by two different cell types. Bifurcated and Z-configured device geometries were evaluated for cell selection. As an example of the performance of these devices, CD4+ T-cells and neutrophils were selected from whole blood as these cells are known to express genes found in stroke-related expression profiles that can be used for the diagnosis of this disease. CD4+ T-cells and neutrophils were simultaneously isolated with purities >90% using affinity-based capture in cyclic olefin copolymer (COC) devices with a processing time of ∼3 min. In addition, sufficient quantities of the cells could be recovered from a 50 μL whole blood input to allow for reverse transcription-polymerase chain reaction (RT-PCR) following cell lysis. The expression of genes from isolated T-cells and neutrophils, such as S100A9, TCRB, and FPR1, was evaluated using RT-PCR. The modification and isolation procedures demonstrated here can also be used to analyze other cell types as well where multiple subsets must be interrogated.
format Online
Article
Text
id pubmed-4004188
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-40041882015-03-20 Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis Pullagurla, Swathi R. Witek, Małgorzata A. Jackson, Joshua M. Lindell, Maria A. M. Hupert, Mateusz L. Nesterova, Irina V. Baird, Alison E. Soper, Steven A. Anal Chem [Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device consisted of four independent selection beds with curvilinear channels that were 25 μm wide and 80 μm deep and were modified with antibodies targeting antigens specifically expressed by two different cell types. Bifurcated and Z-configured device geometries were evaluated for cell selection. As an example of the performance of these devices, CD4+ T-cells and neutrophils were selected from whole blood as these cells are known to express genes found in stroke-related expression profiles that can be used for the diagnosis of this disease. CD4+ T-cells and neutrophils were simultaneously isolated with purities >90% using affinity-based capture in cyclic olefin copolymer (COC) devices with a processing time of ∼3 min. In addition, sufficient quantities of the cells could be recovered from a 50 μL whole blood input to allow for reverse transcription-polymerase chain reaction (RT-PCR) following cell lysis. The expression of genes from isolated T-cells and neutrophils, such as S100A9, TCRB, and FPR1, was evaluated using RT-PCR. The modification and isolation procedures demonstrated here can also be used to analyze other cell types as well where multiple subsets must be interrogated. American Chemical Society 2014-03-20 2014-04-15 /pmc/articles/PMC4004188/ /pubmed/24650222 http://dx.doi.org/10.1021/ac5007766 Text en Copyright © 2014 American Chemical Society
spellingShingle Pullagurla, Swathi R.
Witek, Małgorzata A.
Jackson, Joshua M.
Lindell, Maria A. M.
Hupert, Mateusz L.
Nesterova, Irina V.
Baird, Alison E.
Soper, Steven A.
Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title_full Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title_fullStr Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title_full_unstemmed Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title_short Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
title_sort parallel affinity-based isolation of leukocyte subsets using microfluidics: application for stroke diagnosis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4004188/
https://www.ncbi.nlm.nih.gov/pubmed/24650222
http://dx.doi.org/10.1021/ac5007766
work_keys_str_mv AT pullagurlaswathir parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT witekmałgorzataa parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT jacksonjoshuam parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT lindellmariaam parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT hupertmateuszl parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT nesterovairinav parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT bairdalisone parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis
AT soperstevena parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis