Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis
[Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device cons...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American
Chemical
Society
2014
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4004188/ https://www.ncbi.nlm.nih.gov/pubmed/24650222 http://dx.doi.org/10.1021/ac5007766 |
_version_ | 1782313943553802240 |
---|---|
author | Pullagurla, Swathi R. Witek, Małgorzata A. Jackson, Joshua M. Lindell, Maria A. M. Hupert, Mateusz L. Nesterova, Irina V. Baird, Alison E. Soper, Steven A. |
author_facet | Pullagurla, Swathi R. Witek, Małgorzata A. Jackson, Joshua M. Lindell, Maria A. M. Hupert, Mateusz L. Nesterova, Irina V. Baird, Alison E. Soper, Steven A. |
author_sort | Pullagurla, Swathi R. |
collection | PubMed |
description | [Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device consisted of four independent selection beds with curvilinear channels that were 25 μm wide and 80 μm deep and were modified with antibodies targeting antigens specifically expressed by two different cell types. Bifurcated and Z-configured device geometries were evaluated for cell selection. As an example of the performance of these devices, CD4+ T-cells and neutrophils were selected from whole blood as these cells are known to express genes found in stroke-related expression profiles that can be used for the diagnosis of this disease. CD4+ T-cells and neutrophils were simultaneously isolated with purities >90% using affinity-based capture in cyclic olefin copolymer (COC) devices with a processing time of ∼3 min. In addition, sufficient quantities of the cells could be recovered from a 50 μL whole blood input to allow for reverse transcription-polymerase chain reaction (RT-PCR) following cell lysis. The expression of genes from isolated T-cells and neutrophils, such as S100A9, TCRB, and FPR1, was evaluated using RT-PCR. The modification and isolation procedures demonstrated here can also be used to analyze other cell types as well where multiple subsets must be interrogated. |
format | Online Article Text |
id | pubmed-4004188 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | American
Chemical
Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-40041882015-03-20 Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis Pullagurla, Swathi R. Witek, Małgorzata A. Jackson, Joshua M. Lindell, Maria A. M. Hupert, Mateusz L. Nesterova, Irina V. Baird, Alison E. Soper, Steven A. Anal Chem [Image: see text] We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device consisted of four independent selection beds with curvilinear channels that were 25 μm wide and 80 μm deep and were modified with antibodies targeting antigens specifically expressed by two different cell types. Bifurcated and Z-configured device geometries were evaluated for cell selection. As an example of the performance of these devices, CD4+ T-cells and neutrophils were selected from whole blood as these cells are known to express genes found in stroke-related expression profiles that can be used for the diagnosis of this disease. CD4+ T-cells and neutrophils were simultaneously isolated with purities >90% using affinity-based capture in cyclic olefin copolymer (COC) devices with a processing time of ∼3 min. In addition, sufficient quantities of the cells could be recovered from a 50 μL whole blood input to allow for reverse transcription-polymerase chain reaction (RT-PCR) following cell lysis. The expression of genes from isolated T-cells and neutrophils, such as S100A9, TCRB, and FPR1, was evaluated using RT-PCR. The modification and isolation procedures demonstrated here can also be used to analyze other cell types as well where multiple subsets must be interrogated. American Chemical Society 2014-03-20 2014-04-15 /pmc/articles/PMC4004188/ /pubmed/24650222 http://dx.doi.org/10.1021/ac5007766 Text en Copyright © 2014 American Chemical Society |
spellingShingle | Pullagurla, Swathi R. Witek, Małgorzata A. Jackson, Joshua M. Lindell, Maria A. M. Hupert, Mateusz L. Nesterova, Irina V. Baird, Alison E. Soper, Steven A. Parallel Affinity-Based Isolation of Leukocyte Subsets Using Microfluidics: Application for Stroke Diagnosis |
title | Parallel Affinity-Based Isolation of Leukocyte Subsets
Using Microfluidics: Application for Stroke Diagnosis |
title_full | Parallel Affinity-Based Isolation of Leukocyte Subsets
Using Microfluidics: Application for Stroke Diagnosis |
title_fullStr | Parallel Affinity-Based Isolation of Leukocyte Subsets
Using Microfluidics: Application for Stroke Diagnosis |
title_full_unstemmed | Parallel Affinity-Based Isolation of Leukocyte Subsets
Using Microfluidics: Application for Stroke Diagnosis |
title_short | Parallel Affinity-Based Isolation of Leukocyte Subsets
Using Microfluidics: Application for Stroke Diagnosis |
title_sort | parallel affinity-based isolation of leukocyte subsets
using microfluidics: application for stroke diagnosis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4004188/ https://www.ncbi.nlm.nih.gov/pubmed/24650222 http://dx.doi.org/10.1021/ac5007766 |
work_keys_str_mv | AT pullagurlaswathir parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT witekmałgorzataa parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT jacksonjoshuam parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT lindellmariaam parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT hupertmateuszl parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT nesterovairinav parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT bairdalisone parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis AT soperstevena parallelaffinitybasedisolationofleukocytesubsetsusingmicrofluidicsapplicationforstrokediagnosis |