Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms
BACKGROUND: Nowadays, there are many methods to reduce microorganisms in the air, such as dehumidifier, air purifier or humidity and temperature controller. The Precise Climate Controller is an instrument for controlling humidity and temperature, a concept that is demonstrated. OBJECTIVE: To determi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Asia Pacific Association of Allergy, Asthma and Clinical Immunology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4005345/ https://www.ncbi.nlm.nih.gov/pubmed/24809017 http://dx.doi.org/10.5415/apallergy.2014.4.2.113 |
_version_ | 1782314092002803712 |
---|---|
author | Moungthong, Greetha Klamkam, Pana Mahakit, Prasit Chalermwatanachai, Thanit Thunyaharn, Sudaluck Monyakul, Veerapol |
author_facet | Moungthong, Greetha Klamkam, Pana Mahakit, Prasit Chalermwatanachai, Thanit Thunyaharn, Sudaluck Monyakul, Veerapol |
author_sort | Moungthong, Greetha |
collection | PubMed |
description | BACKGROUND: Nowadays, there are many methods to reduce microorganisms in the air, such as dehumidifier, air purifier or humidity and temperature controller. The Precise Climate Controller is an instrument for controlling humidity and temperature, a concept that is demonstrated. OBJECTIVE: To determine the efficacy of this device, in order to reduce the quantity of the fungi and bacteria in the closed system. METHODS: This study is a perspective experimental study and is conducted as follows - the air sample in the closed system, a 42-cubic-meter room, is collected before the installation of the Precise Climate Controller. Next, the room is fumed with Aspergillus flavus and closed for 2 days. Then the instrument is in use in order to keep the relative humidity (RH) and the temperature constant at 55% RH and 25 degrees Celsius (℃). The air samples are collected every 3 days for 5 times during the period of 15 days to identify the type and calculate the quantity of the microorganisms. RESULTS: Before the Precise Climate Controller has been installed. Three species of bacteria are found in the air samples, but none of the fungus exists in the testing room. Once the room has been fumed with a large amount of A. flavus and the instrument is in use for 3 days, nine colonies of A. flavus are identified, but later on when the instrument is in use for 6, 9, 12, and 15 days, the air samples contain neither fungus nor bacteria. CONCLUSION: After keeping the RH and temperature of the closed system constant at 55% RH and 25℃ by using the Precise Climate Controller, it is found that the efficaciousness in controlling the quantity and species of fungi and bacteria is clinically significant. |
format | Online Article Text |
id | pubmed-4005345 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Asia Pacific Association of Allergy, Asthma and Clinical Immunology |
record_format | MEDLINE/PubMed |
spelling | pubmed-40053452014-05-07 Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms Moungthong, Greetha Klamkam, Pana Mahakit, Prasit Chalermwatanachai, Thanit Thunyaharn, Sudaluck Monyakul, Veerapol Asia Pac Allergy Hypothesis & Experience BACKGROUND: Nowadays, there are many methods to reduce microorganisms in the air, such as dehumidifier, air purifier or humidity and temperature controller. The Precise Climate Controller is an instrument for controlling humidity and temperature, a concept that is demonstrated. OBJECTIVE: To determine the efficacy of this device, in order to reduce the quantity of the fungi and bacteria in the closed system. METHODS: This study is a perspective experimental study and is conducted as follows - the air sample in the closed system, a 42-cubic-meter room, is collected before the installation of the Precise Climate Controller. Next, the room is fumed with Aspergillus flavus and closed for 2 days. Then the instrument is in use in order to keep the relative humidity (RH) and the temperature constant at 55% RH and 25 degrees Celsius (℃). The air samples are collected every 3 days for 5 times during the period of 15 days to identify the type and calculate the quantity of the microorganisms. RESULTS: Before the Precise Climate Controller has been installed. Three species of bacteria are found in the air samples, but none of the fungus exists in the testing room. Once the room has been fumed with a large amount of A. flavus and the instrument is in use for 3 days, nine colonies of A. flavus are identified, but later on when the instrument is in use for 6, 9, 12, and 15 days, the air samples contain neither fungus nor bacteria. CONCLUSION: After keeping the RH and temperature of the closed system constant at 55% RH and 25℃ by using the Precise Climate Controller, it is found that the efficaciousness in controlling the quantity and species of fungi and bacteria is clinically significant. Asia Pacific Association of Allergy, Asthma and Clinical Immunology 2014-04 2014-04-29 /pmc/articles/PMC4005345/ /pubmed/24809017 http://dx.doi.org/10.5415/apallergy.2014.4.2.113 Text en Copyright © 2014. Asia Pacific Association of Allergy, Asthma and Clinical Immunology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Hypothesis & Experience Moungthong, Greetha Klamkam, Pana Mahakit, Prasit Chalermwatanachai, Thanit Thunyaharn, Sudaluck Monyakul, Veerapol Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title | Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title_full | Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title_fullStr | Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title_full_unstemmed | Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title_short | Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms |
title_sort | efficacy of the precise climate controller on the reduction of indoor microorganisms |
topic | Hypothesis & Experience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4005345/ https://www.ncbi.nlm.nih.gov/pubmed/24809017 http://dx.doi.org/10.5415/apallergy.2014.4.2.113 |
work_keys_str_mv | AT moungthonggreetha efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms AT klamkampana efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms AT mahakitprasit efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms AT chalermwatanachaithanit efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms AT thunyaharnsudaluck efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms AT monyakulveerapol efficacyofthepreciseclimatecontrolleronthereductionofindoormicroorganisms |