Cargando…

Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases

Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophena...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalmár, É, Kormányos, B., Szakonyi, G., Dombi, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007253/
https://www.ncbi.nlm.nih.gov/pubmed/24799736
_version_ 1782314319398043648
author Kalmár, É
Kormányos, B.
Szakonyi, G.
Dombi, G.
author_facet Kalmár, É
Kormányos, B.
Szakonyi, G.
Dombi, G.
author_sort Kalmár, É
collection PubMed
description Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine.
format Online
Article
Text
id pubmed-4007253
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40072532014-05-05 Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases Kalmár, É Kormányos, B. Szakonyi, G. Dombi, G. Indian J Pharm Sci Research Paper Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4007253/ /pubmed/24799736 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Paper
Kalmár, É
Kormányos, B.
Szakonyi, G.
Dombi, G.
Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title_full Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title_fullStr Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title_full_unstemmed Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title_short Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
title_sort validated hplc determination of 4-dimethylaminoantipyrine in different suppository bases
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007253/
https://www.ncbi.nlm.nih.gov/pubmed/24799736
work_keys_str_mv AT kalmare validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases
AT kormanyosb validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases
AT szakonyig validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases
AT dombig validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases