Cargando…
Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophena...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007253/ https://www.ncbi.nlm.nih.gov/pubmed/24799736 |
_version_ | 1782314319398043648 |
---|---|
author | Kalmár, É Kormányos, B. Szakonyi, G. Dombi, G. |
author_facet | Kalmár, É Kormányos, B. Szakonyi, G. Dombi, G. |
author_sort | Kalmár, É |
collection | PubMed |
description | Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. |
format | Online Article Text |
id | pubmed-4007253 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-40072532014-05-05 Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases Kalmár, É Kormányos, B. Szakonyi, G. Dombi, G. Indian J Pharm Sci Research Paper Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4007253/ /pubmed/24799736 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Paper Kalmár, É Kormányos, B. Szakonyi, G. Dombi, G. Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title | Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title_full | Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title_fullStr | Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title_full_unstemmed | Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title_short | Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases |
title_sort | validated hplc determination of 4-dimethylaminoantipyrine in different suppository bases |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007253/ https://www.ncbi.nlm.nih.gov/pubmed/24799736 |
work_keys_str_mv | AT kalmare validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases AT kormanyosb validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases AT szakonyig validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases AT dombig validatedhplcdeterminationof4dimethylaminoantipyrineindifferentsuppositorybases |