Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients

BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes c...

Descripción completa

Detalles Bibliográficos
Autores principales: Karami, Azadeh, Baradaran, Azar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007341/
https://www.ncbi.nlm.nih.gov/pubmed/24800183
http://dx.doi.org/10.4103/2277-9175.129364
_version_ 1782314329824034816
author Karami, Azadeh
Baradaran, Azar
author_facet Karami, Azadeh
Baradaran, Azar
author_sort Karami, Azadeh
collection PubMed
description BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes care and predict the risk for the development of complications. While HbA(1c) is the standard method for long-term glycemic control in diabetic patients, there are different methods for measurement of HbA(1c) and all laboratories do not use the reference method (high-performance liquid chromatography [HPLC]). The objective of this study is comparison of three different methods with HPLC to find out which method has an acceptable concordance and correlation with the reference method. MATERIALS AND METHODS: Fifty-eight diabetic patients were assessed in this study. The blood sample of each patient was checked with Diazyme (enzymatic assay), Nycocard (boronate-affinity binding) and Biosystem (micro column chromatography). The values of HbA(1c) of each method were compared with the Knauer-HPLC results. RESULTS: The means of the differential values between each method and HPLC in the ANOVA test are as follows: M = 1.8, SD = 1.09 for Nycocard-HPLC; M = 1.5, SD = 1.08 for biosystem-HPLC; M = 1.3, SD = 1.2 for Diazyme-HPLC. Pearson's correlation coefficient between HPLC and Nycocard; 0.76, HPLC and Diazyme; 0.75 and between HPLC and Biosystem was 0.68. Linear regression parameters for each method with HPLC were also determined. CONCLUSION: Diazyme had a better performance and showed a greater concordance with HPLC among others, although it was not an ideal alternative for HPLC.
format Online
Article
Text
id pubmed-4007341
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40073412014-05-05 Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients Karami, Azadeh Baradaran, Azar Adv Biomed Res Original Article BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes care and predict the risk for the development of complications. While HbA(1c) is the standard method for long-term glycemic control in diabetic patients, there are different methods for measurement of HbA(1c) and all laboratories do not use the reference method (high-performance liquid chromatography [HPLC]). The objective of this study is comparison of three different methods with HPLC to find out which method has an acceptable concordance and correlation with the reference method. MATERIALS AND METHODS: Fifty-eight diabetic patients were assessed in this study. The blood sample of each patient was checked with Diazyme (enzymatic assay), Nycocard (boronate-affinity binding) and Biosystem (micro column chromatography). The values of HbA(1c) of each method were compared with the Knauer-HPLC results. RESULTS: The means of the differential values between each method and HPLC in the ANOVA test are as follows: M = 1.8, SD = 1.09 for Nycocard-HPLC; M = 1.5, SD = 1.08 for biosystem-HPLC; M = 1.3, SD = 1.2 for Diazyme-HPLC. Pearson's correlation coefficient between HPLC and Nycocard; 0.76, HPLC and Diazyme; 0.75 and between HPLC and Biosystem was 0.68. Linear regression parameters for each method with HPLC were also determined. CONCLUSION: Diazyme had a better performance and showed a greater concordance with HPLC among others, although it was not an ideal alternative for HPLC. Medknow Publications & Media Pvt Ltd 2014-03-25 /pmc/articles/PMC4007341/ /pubmed/24800183 http://dx.doi.org/10.4103/2277-9175.129364 Text en Copyright: © 2014 Karami. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Karami, Azadeh
Baradaran, Azar
Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title_full Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title_fullStr Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title_full_unstemmed Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title_short Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
title_sort comparative evaluation of three different methods for hba(1c) measurement with high-performance liquid chromatography in diabetic patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007341/
https://www.ncbi.nlm.nih.gov/pubmed/24800183
http://dx.doi.org/10.4103/2277-9175.129364
work_keys_str_mv AT karamiazadeh comparativeevaluationofthreedifferentmethodsforhba1cmeasurementwithhighperformanceliquidchromatographyindiabeticpatients
AT baradaranazar comparativeevaluationofthreedifferentmethodsforhba1cmeasurementwithhighperformanceliquidchromatographyindiabeticpatients