Cargando…
Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients
BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes c...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007341/ https://www.ncbi.nlm.nih.gov/pubmed/24800183 http://dx.doi.org/10.4103/2277-9175.129364 |
_version_ | 1782314329824034816 |
---|---|
author | Karami, Azadeh Baradaran, Azar |
author_facet | Karami, Azadeh Baradaran, Azar |
author_sort | Karami, Azadeh |
collection | PubMed |
description | BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes care and predict the risk for the development of complications. While HbA(1c) is the standard method for long-term glycemic control in diabetic patients, there are different methods for measurement of HbA(1c) and all laboratories do not use the reference method (high-performance liquid chromatography [HPLC]). The objective of this study is comparison of three different methods with HPLC to find out which method has an acceptable concordance and correlation with the reference method. MATERIALS AND METHODS: Fifty-eight diabetic patients were assessed in this study. The blood sample of each patient was checked with Diazyme (enzymatic assay), Nycocard (boronate-affinity binding) and Biosystem (micro column chromatography). The values of HbA(1c) of each method were compared with the Knauer-HPLC results. RESULTS: The means of the differential values between each method and HPLC in the ANOVA test are as follows: M = 1.8, SD = 1.09 for Nycocard-HPLC; M = 1.5, SD = 1.08 for biosystem-HPLC; M = 1.3, SD = 1.2 for Diazyme-HPLC. Pearson's correlation coefficient between HPLC and Nycocard; 0.76, HPLC and Diazyme; 0.75 and between HPLC and Biosystem was 0.68. Linear regression parameters for each method with HPLC were also determined. CONCLUSION: Diazyme had a better performance and showed a greater concordance with HPLC among others, although it was not an ideal alternative for HPLC. |
format | Online Article Text |
id | pubmed-4007341 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-40073412014-05-05 Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients Karami, Azadeh Baradaran, Azar Adv Biomed Res Original Article BACKGROUND: The global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA(1c), is fundamental to the management of patients with diabetes. HbA(1c) is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes care and predict the risk for the development of complications. While HbA(1c) is the standard method for long-term glycemic control in diabetic patients, there are different methods for measurement of HbA(1c) and all laboratories do not use the reference method (high-performance liquid chromatography [HPLC]). The objective of this study is comparison of three different methods with HPLC to find out which method has an acceptable concordance and correlation with the reference method. MATERIALS AND METHODS: Fifty-eight diabetic patients were assessed in this study. The blood sample of each patient was checked with Diazyme (enzymatic assay), Nycocard (boronate-affinity binding) and Biosystem (micro column chromatography). The values of HbA(1c) of each method were compared with the Knauer-HPLC results. RESULTS: The means of the differential values between each method and HPLC in the ANOVA test are as follows: M = 1.8, SD = 1.09 for Nycocard-HPLC; M = 1.5, SD = 1.08 for biosystem-HPLC; M = 1.3, SD = 1.2 for Diazyme-HPLC. Pearson's correlation coefficient between HPLC and Nycocard; 0.76, HPLC and Diazyme; 0.75 and between HPLC and Biosystem was 0.68. Linear regression parameters for each method with HPLC were also determined. CONCLUSION: Diazyme had a better performance and showed a greater concordance with HPLC among others, although it was not an ideal alternative for HPLC. Medknow Publications & Media Pvt Ltd 2014-03-25 /pmc/articles/PMC4007341/ /pubmed/24800183 http://dx.doi.org/10.4103/2277-9175.129364 Text en Copyright: © 2014 Karami. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Article Karami, Azadeh Baradaran, Azar Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title | Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title_full | Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title_fullStr | Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title_full_unstemmed | Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title_short | Comparative evaluation of three different methods for HbA(1c) measurement with High-performance liquid chromatography in diabetic patients |
title_sort | comparative evaluation of three different methods for hba(1c) measurement with high-performance liquid chromatography in diabetic patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007341/ https://www.ncbi.nlm.nih.gov/pubmed/24800183 http://dx.doi.org/10.4103/2277-9175.129364 |
work_keys_str_mv | AT karamiazadeh comparativeevaluationofthreedifferentmethodsforhba1cmeasurementwithhighperformanceliquidchromatographyindiabeticpatients AT baradaranazar comparativeevaluationofthreedifferentmethodsforhba1cmeasurementwithhighperformanceliquidchromatographyindiabeticpatients |