Cargando…

An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule

PURPOSE: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from l...

Descripción completa

Detalles Bibliográficos
Autores principales: Miftari, Ramë, Fejza, Ferki, Bicaj, Xhavit, Nura, Adem, Topciu, Valdete, Bajrami, Ismet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AVICENA, d.o.o., Sarajevo 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008031/
https://www.ncbi.nlm.nih.gov/pubmed/24825932
http://dx.doi.org/10.5455/aim.2014.22.94-97
_version_ 1782314392359010304
author Miftari, Ramë
Fejza, Ferki
Bicaj, Xhavit
Nura, Adem
Topciu, Valdete
Bajrami, Ismet
author_facet Miftari, Ramë
Fejza, Ferki
Bicaj, Xhavit
Nura, Adem
Topciu, Valdete
Bajrami, Ismet
author_sort Miftari, Ramë
collection PubMed
description PURPOSE: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from lobe agenesis. Our interest was to estimate and determinate the rate of radioactivity when the source with high activity can make total suppression of the second source with low activity in same conditions with thyroid scintigraphy procedures. MATERIAL AND METHODOLOGY: Thyroid scintigraphy was performed with Technetium 99 meta stable pertechnetate. A parallel high resolution low energy collimator was used as an energy setting of 140 KeV photo peak for T-99m. Images are acquired at 200 Kilo Counts in the anterior projection with the collimator positioned as close as the patient’s extended neck (approximately in distance of 18 cm). The scintigraphy of thyroid gland was performed 15 minutes after intravenous administration of 1.5 mCi Tc-99m pertechnetate. Technetium 99 meta stable radioactive sources with different activity were used for two scintigraphies studies, performed in same thyroid scintigraphy acquisition procedures. In the first study, were compared the standard source with high activity A=11.2 mCi with sources with variable activities B=1.33 mCi; 1.03 mCi; 0.7 mCi; 0.36 mCi; and 0.16mCi) in distance of 1.5cm from each other sources, which is approximately same with distance between two thyroid lobes. In the second study were compared the sources with low activity in proportion 70:1(source A = 1.5 mCi and source B=0.021mCi). As clinical studies we preferred two different patents with different thyroid disorders. There were one patient with thyroid toxic nodule in the right lobe, therefore the second patient was with left thyroid nodule agenesis. RESULTS: During our examination, we accurately determined that two radioactive sources in proportion 70:1 will be displayed as only one source with complete suppression of other source with low radioactivity. Also we found that covering of toxic nodules with lead cover (plaque), can allow visualization of activity in suppressed lobe. CONCLUSION: Our study concluded that total lobe suppression, in cases of patients with thyroid toxic nodule, will happened for sure, if toxic nodule had accumulated seventy times more radioactivity than normal lobe. Also we concluded that covering of the toxic nodule with lead plaque, may permit the presentation of radioactivity in suppressed nodule.
format Online
Article
Text
id pubmed-4008031
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher AVICENA, d.o.o., Sarajevo
record_format MEDLINE/PubMed
spelling pubmed-40080312014-05-13 An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule Miftari, Ramë Fejza, Ferki Bicaj, Xhavit Nura, Adem Topciu, Valdete Bajrami, Ismet Acta Inform Med Original Paper PURPOSE: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from lobe agenesis. Our interest was to estimate and determinate the rate of radioactivity when the source with high activity can make total suppression of the second source with low activity in same conditions with thyroid scintigraphy procedures. MATERIAL AND METHODOLOGY: Thyroid scintigraphy was performed with Technetium 99 meta stable pertechnetate. A parallel high resolution low energy collimator was used as an energy setting of 140 KeV photo peak for T-99m. Images are acquired at 200 Kilo Counts in the anterior projection with the collimator positioned as close as the patient’s extended neck (approximately in distance of 18 cm). The scintigraphy of thyroid gland was performed 15 minutes after intravenous administration of 1.5 mCi Tc-99m pertechnetate. Technetium 99 meta stable radioactive sources with different activity were used for two scintigraphies studies, performed in same thyroid scintigraphy acquisition procedures. In the first study, were compared the standard source with high activity A=11.2 mCi with sources with variable activities B=1.33 mCi; 1.03 mCi; 0.7 mCi; 0.36 mCi; and 0.16mCi) in distance of 1.5cm from each other sources, which is approximately same with distance between two thyroid lobes. In the second study were compared the sources with low activity in proportion 70:1(source A = 1.5 mCi and source B=0.021mCi). As clinical studies we preferred two different patents with different thyroid disorders. There were one patient with thyroid toxic nodule in the right lobe, therefore the second patient was with left thyroid nodule agenesis. RESULTS: During our examination, we accurately determined that two radioactive sources in proportion 70:1 will be displayed as only one source with complete suppression of other source with low radioactivity. Also we found that covering of toxic nodules with lead cover (plaque), can allow visualization of activity in suppressed lobe. CONCLUSION: Our study concluded that total lobe suppression, in cases of patients with thyroid toxic nodule, will happened for sure, if toxic nodule had accumulated seventy times more radioactivity than normal lobe. Also we concluded that covering of the toxic nodule with lead plaque, may permit the presentation of radioactivity in suppressed nodule. AVICENA, d.o.o., Sarajevo 2014-03-17 2014-04 /pmc/articles/PMC4008031/ /pubmed/24825932 http://dx.doi.org/10.5455/aim.2014.22.94-97 Text en Copyright: © AVICENA http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Miftari, Ramë
Fejza, Ferki
Bicaj, Xhavit
Nura, Adem
Topciu, Valdete
Bajrami, Ismet
An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title_full An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title_fullStr An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title_full_unstemmed An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title_short An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule
title_sort experimental comparison of two different technetium source activities which can imitate thyroid scintigraphy in case of thyroid toxic nodule
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008031/
https://www.ncbi.nlm.nih.gov/pubmed/24825932
http://dx.doi.org/10.5455/aim.2014.22.94-97
work_keys_str_mv AT miftarirame anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT fejzaferki anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT bicajxhavit anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT nuraadem anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT topciuvaldete anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT bajramiismet anexperimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT miftarirame experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT fejzaferki experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT bicajxhavit experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT nuraadem experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT topciuvaldete experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule
AT bajramiismet experimentalcomparisonoftwodifferenttechnetiumsourceactivitieswhichcanimitatethyroidscintigraphyincaseofthyroidtoxicnodule