Cargando…
Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory
Coronary malperfusion due to type A aortic dissection is a life-threatening condition where timely recognition and treatment are mandatory. A 77-year-old woman underwent an acute evolving type A aortic dissection mimicking acute myocardial infarction. Two pathophysiologic mechanisms are discussed: e...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008343/ https://www.ncbi.nlm.nih.gov/pubmed/24826248 http://dx.doi.org/10.1155/2012/367542 |
_version_ | 1782314426882326528 |
---|---|
author | Arrivi, Alessio Tanzilli, Gaetano Puddu, Paolo Emilio Truscelli, Giovanni Dominici, Marcello Mangieri, Enrico |
author_facet | Arrivi, Alessio Tanzilli, Gaetano Puddu, Paolo Emilio Truscelli, Giovanni Dominici, Marcello Mangieri, Enrico |
author_sort | Arrivi, Alessio |
collection | PubMed |
description | Coronary malperfusion due to type A aortic dissection is a life-threatening condition where timely recognition and treatment are mandatory. A 77-year-old woman underwent an acute evolving type A aortic dissection mimicking acute myocardial infarction. Two pathophysiologic mechanisms are discussed: either thrombosis migrating from a previously treated giant aneurism of proximal left anterior descending or a local arterial complication due to left main stenting. Recognition of these occurrences in the catheterization laboratory is important to look immediately for surgery. |
format | Online Article Text |
id | pubmed-4008343 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40083432014-05-13 Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory Arrivi, Alessio Tanzilli, Gaetano Puddu, Paolo Emilio Truscelli, Giovanni Dominici, Marcello Mangieri, Enrico Case Rep Cardiol Case Report Coronary malperfusion due to type A aortic dissection is a life-threatening condition where timely recognition and treatment are mandatory. A 77-year-old woman underwent an acute evolving type A aortic dissection mimicking acute myocardial infarction. Two pathophysiologic mechanisms are discussed: either thrombosis migrating from a previously treated giant aneurism of proximal left anterior descending or a local arterial complication due to left main stenting. Recognition of these occurrences in the catheterization laboratory is important to look immediately for surgery. Hindawi Publishing Corporation 2012 2012-09-27 /pmc/articles/PMC4008343/ /pubmed/24826248 http://dx.doi.org/10.1155/2012/367542 Text en Copyright © 2012 Alessio Arrivi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Arrivi, Alessio Tanzilli, Gaetano Puddu, Paolo Emilio Truscelli, Giovanni Dominici, Marcello Mangieri, Enrico Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title | Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title_full | Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title_fullStr | Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title_full_unstemmed | Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title_short | Acute Aortic Dissection Mimicking STEMI in the Catheterization Laboratory: Early Recognition Is Mandatory |
title_sort | acute aortic dissection mimicking stemi in the catheterization laboratory: early recognition is mandatory |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008343/ https://www.ncbi.nlm.nih.gov/pubmed/24826248 http://dx.doi.org/10.1155/2012/367542 |
work_keys_str_mv | AT arrivialessio acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory AT tanzilligaetano acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory AT puddupaoloemilio acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory AT truscelligiovanni acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory AT dominicimarcello acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory AT mangierienrico acuteaorticdissectionmimickingstemiinthecatheterizationlaboratoryearlyrecognitionismandatory |