Cargando…
Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left vent...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008347/ https://www.ncbi.nlm.nih.gov/pubmed/24826249 http://dx.doi.org/10.1155/2012/387103 |
_version_ | 1782314427912028160 |
---|---|
author | Calé, Rita Neves, José Teles, Rui Brito, João Abecasis, Miguel Almeida, Manuel Nolasco, Tiago Mendes, Miguel |
author_facet | Calé, Rita Neves, José Teles, Rui Brito, João Abecasis, Miguel Almeida, Manuel Nolasco, Tiago Mendes, Miguel |
author_sort | Calé, Rita |
collection | PubMed |
description | Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon post-dilatation, and therefore she was successfully treated with open-heart surgery to remove the malfunctioning CoreValve bioprosthesis and perform standard aortic valve replacement. |
format | Online Article Text |
id | pubmed-4008347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40083472014-05-13 Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis Calé, Rita Neves, José Teles, Rui Brito, João Abecasis, Miguel Almeida, Manuel Nolasco, Tiago Mendes, Miguel Case Rep Cardiol Case Report Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon post-dilatation, and therefore she was successfully treated with open-heart surgery to remove the malfunctioning CoreValve bioprosthesis and perform standard aortic valve replacement. Hindawi Publishing Corporation 2012 2012-07-19 /pmc/articles/PMC4008347/ /pubmed/24826249 http://dx.doi.org/10.1155/2012/387103 Text en Copyright © 2012 Rita Calé et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Calé, Rita Neves, José Teles, Rui Brito, João Abecasis, Miguel Almeida, Manuel Nolasco, Tiago Mendes, Miguel Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title | Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title_full | Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title_fullStr | Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title_full_unstemmed | Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title_short | Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis |
title_sort | surgical bailout therapy after implantation of a medtronic corevalve bioprosthesis |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008347/ https://www.ncbi.nlm.nih.gov/pubmed/24826249 http://dx.doi.org/10.1155/2012/387103 |
work_keys_str_mv | AT calerita surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT nevesjose surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT telesrui surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT britojoao surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT abecasismiguel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT almeidamanuel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT nolascotiago surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis AT mendesmiguel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis |