Cargando…

Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis

Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left vent...

Descripción completa

Detalles Bibliográficos
Autores principales: Calé, Rita, Neves, José, Teles, Rui, Brito, João, Abecasis, Miguel, Almeida, Manuel, Nolasco, Tiago, Mendes, Miguel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008347/
https://www.ncbi.nlm.nih.gov/pubmed/24826249
http://dx.doi.org/10.1155/2012/387103
_version_ 1782314427912028160
author Calé, Rita
Neves, José
Teles, Rui
Brito, João
Abecasis, Miguel
Almeida, Manuel
Nolasco, Tiago
Mendes, Miguel
author_facet Calé, Rita
Neves, José
Teles, Rui
Brito, João
Abecasis, Miguel
Almeida, Manuel
Nolasco, Tiago
Mendes, Miguel
author_sort Calé, Rita
collection PubMed
description Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon post-dilatation, and therefore she was successfully treated with open-heart surgery to remove the malfunctioning CoreValve bioprosthesis and perform standard aortic valve replacement.
format Online
Article
Text
id pubmed-4008347
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40083472014-05-13 Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis Calé, Rita Neves, José Teles, Rui Brito, João Abecasis, Miguel Almeida, Manuel Nolasco, Tiago Mendes, Miguel Case Rep Cardiol Case Report Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon post-dilatation, and therefore she was successfully treated with open-heart surgery to remove the malfunctioning CoreValve bioprosthesis and perform standard aortic valve replacement. Hindawi Publishing Corporation 2012 2012-07-19 /pmc/articles/PMC4008347/ /pubmed/24826249 http://dx.doi.org/10.1155/2012/387103 Text en Copyright © 2012 Rita Calé et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Calé, Rita
Neves, José
Teles, Rui
Brito, João
Abecasis, Miguel
Almeida, Manuel
Nolasco, Tiago
Mendes, Miguel
Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title_full Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title_fullStr Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title_full_unstemmed Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title_short Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
title_sort surgical bailout therapy after implantation of a medtronic corevalve bioprosthesis
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008347/
https://www.ncbi.nlm.nih.gov/pubmed/24826249
http://dx.doi.org/10.1155/2012/387103
work_keys_str_mv AT calerita surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT nevesjose surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT telesrui surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT britojoao surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT abecasismiguel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT almeidamanuel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT nolascotiago surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis
AT mendesmiguel surgicalbailouttherapyafterimplantationofamedtroniccorevalvebioprosthesis