Cargando…

Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()

INTRODUCTION: Adequate exposure is a vital factor in total laparoscopic hysterectomy, and uterine manipulators have been used in achieving that. The Hohl uterine manipulator has been considered to be one of the safer manipulators. Beside adequate exposure, it is associated with lower intraoperative...

Descripción completa

Detalles Bibliográficos
Autores principales: Akdemir, Ali, Cirpan, Teksin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008850/
https://www.ncbi.nlm.nih.gov/pubmed/24721564
http://dx.doi.org/10.1016/j.ijscr.2013.10.005
_version_ 1782314516576468992
author Akdemir, Ali
Cirpan, Teksin
author_facet Akdemir, Ali
Cirpan, Teksin
author_sort Akdemir, Ali
collection PubMed
description INTRODUCTION: Adequate exposure is a vital factor in total laparoscopic hysterectomy, and uterine manipulators have been used in achieving that. The Hohl uterine manipulator has been considered to be one of the safer manipulators. Beside adequate exposure, it is associated with lower intraoperative complications. However, we report a case of iatrogenic uterine rupture with the Hohl manipulator which also caused bowel penetration. PRESENTATION OF CASE: A 52-year-old woman with endometrial hyperplasia was scheduled for total laparoscopic hysterectomy. Prior to entering into the abdomen, the Hohl uterine manipulator was introduced into the uterine cavity without force. During the laparoscopic exploration, we noted that the tip of the Hohl manipulator had perforated the posterior uterine fundus and penetrated the bowel. Therefore, laparotomy was performed, and the bowel injury was repaired by a colorectal surgeon. DISCUSSION: The Hohl uterine manipulator is safe and easy to use, and is associated with decreased intraoperative injuries. However, the complications observed due to the improper use of an uterine manipulator can overshadow any advantages of manipulator. In the present report, we describe a case of uterine perforation and bowel penetration caused by the Hohl uterine manipulator during total laparoscopic hysterectomy, which required conversion to laparotomy. The cause for this complication is associated with improper usage of the uterine manipulator. CONCLUSION: Uterine manipulator may cause uterine perforation and bowel penetration at the beginning of the hysterectomy procedure. These types of complications can be prevented by proper application of the Hohl manipulator into the uterus under direct pelvic visualization.
format Online
Article
Text
id pubmed-4008850
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-40088502014-05-06 Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report() Akdemir, Ali Cirpan, Teksin Int J Surg Case Rep Article INTRODUCTION: Adequate exposure is a vital factor in total laparoscopic hysterectomy, and uterine manipulators have been used in achieving that. The Hohl uterine manipulator has been considered to be one of the safer manipulators. Beside adequate exposure, it is associated with lower intraoperative complications. However, we report a case of iatrogenic uterine rupture with the Hohl manipulator which also caused bowel penetration. PRESENTATION OF CASE: A 52-year-old woman with endometrial hyperplasia was scheduled for total laparoscopic hysterectomy. Prior to entering into the abdomen, the Hohl uterine manipulator was introduced into the uterine cavity without force. During the laparoscopic exploration, we noted that the tip of the Hohl manipulator had perforated the posterior uterine fundus and penetrated the bowel. Therefore, laparotomy was performed, and the bowel injury was repaired by a colorectal surgeon. DISCUSSION: The Hohl uterine manipulator is safe and easy to use, and is associated with decreased intraoperative injuries. However, the complications observed due to the improper use of an uterine manipulator can overshadow any advantages of manipulator. In the present report, we describe a case of uterine perforation and bowel penetration caused by the Hohl uterine manipulator during total laparoscopic hysterectomy, which required conversion to laparotomy. The cause for this complication is associated with improper usage of the uterine manipulator. CONCLUSION: Uterine manipulator may cause uterine perforation and bowel penetration at the beginning of the hysterectomy procedure. These types of complications can be prevented by proper application of the Hohl manipulator into the uterus under direct pelvic visualization. Elsevier 2014-03-19 /pmc/articles/PMC4008850/ /pubmed/24721564 http://dx.doi.org/10.1016/j.ijscr.2013.10.005 Text en © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-No Derivative Works License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Akdemir, Ali
Cirpan, Teksin
Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title_full Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title_fullStr Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title_full_unstemmed Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title_short Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report()
title_sort iatrogenic uterine perforation and bowel penetration using a hohlmanipulator: a case report()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008850/
https://www.ncbi.nlm.nih.gov/pubmed/24721564
http://dx.doi.org/10.1016/j.ijscr.2013.10.005
work_keys_str_mv AT akdemirali iatrogenicuterineperforationandbowelpenetrationusingahohlmanipulatoracasereport
AT cirpanteksin iatrogenicuterineperforationandbowelpenetrationusingahohlmanipulatoracasereport