Cargando…

Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode

A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13-tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III)-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumte...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Ashok Kumar, Singh, Rupam, Saxena, Puja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008869/
http://dx.doi.org/10.3390/s041200187
_version_ 1782314517711028224
author Singh, Ashok Kumar
Singh, Rupam
Saxena, Puja
author_facet Singh, Ashok Kumar
Singh, Rupam
Saxena, Puja
author_sort Singh, Ashok Kumar
collection PubMed
description A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13-tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III)-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumtetraphenyl borate composition 1:4:1:1 with a Nernstian slope of 19.0 mV per decade of concentration between pH 3.0 and 6.5. This electrode has been found to be chemically inert and of adequate stability with a response time of 20 s and was used over a period of 100 d with good reproducibility (S= 0.3 mV). The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 30% (v/v) content of methanol and ethanol. The potentiometric selectivity coefficient values indicate that the membrane sensor is highly selective for Cr(III) ions over a number of monovalent, divalent and trivalent cations. The membrane electrode has also been successfully used to determine Cr(3+) in various food materials.
format Online
Article
Text
id pubmed-4008869
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-40088692014-05-05 Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode Singh, Ashok Kumar Singh, Rupam Saxena, Puja Sensors (Basel) Article A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13-tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III)-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumtetraphenyl borate composition 1:4:1:1 with a Nernstian slope of 19.0 mV per decade of concentration between pH 3.0 and 6.5. This electrode has been found to be chemically inert and of adequate stability with a response time of 20 s and was used over a period of 100 d with good reproducibility (S= 0.3 mV). The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 30% (v/v) content of methanol and ethanol. The potentiometric selectivity coefficient values indicate that the membrane sensor is highly selective for Cr(III) ions over a number of monovalent, divalent and trivalent cations. The membrane electrode has also been successfully used to determine Cr(3+) in various food materials. Molecular Diversity Preservation International (MDPI) 2004-12-22 /pmc/articles/PMC4008869/ http://dx.doi.org/10.3390/s041200187 Text en © 2004 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Singh, Ashok Kumar
Singh, Rupam
Saxena, Puja
Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title_full Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title_fullStr Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title_full_unstemmed Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title_short Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode
title_sort tetraazacyclohexadeca macrocyclic ligand as a neutral carrier in a cr ion-selective electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008869/
http://dx.doi.org/10.3390/s041200187
work_keys_str_mv AT singhashokkumar tetraazacyclohexadecamacrocyclicligandasaneutralcarrierinacrionselectiveelectrode
AT singhrupam tetraazacyclohexadecamacrocyclicligandasaneutralcarrierinacrionselectiveelectrode
AT saxenapuja tetraazacyclohexadecamacrocyclicligandasaneutralcarrierinacrionselectiveelectrode