Cargando…

A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography

PURPOSE: To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT). METHODS: We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-sclera...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Preeti, Sidhartha, Elizabeth, Girard, Michael J. A., Mari, Jean Martial, Wong, Tien-Yin, Cheng, Ching-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4010516/
https://www.ncbi.nlm.nih.gov/pubmed/24797674
http://dx.doi.org/10.1371/journal.pone.0096661
_version_ 1782479869588799488
author Gupta, Preeti
Sidhartha, Elizabeth
Girard, Michael J. A.
Mari, Jean Martial
Wong, Tien-Yin
Cheng, Ching-Yu
author_facet Gupta, Preeti
Sidhartha, Elizabeth
Girard, Michael J. A.
Mari, Jean Martial
Wong, Tien-Yin
Cheng, Ching-Yu
author_sort Gupta, Preeti
collection PubMed
description PURPOSE: To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT). METHODS: We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses. RESULTS: Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively. CONCLUSIONS: The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement.
format Online
Article
Text
id pubmed-4010516
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-40105162014-05-09 A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography Gupta, Preeti Sidhartha, Elizabeth Girard, Michael J. A. Mari, Jean Martial Wong, Tien-Yin Cheng, Ching-Yu PLoS One Research Article PURPOSE: To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT). METHODS: We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses. RESULTS: Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively. CONCLUSIONS: The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement. Public Library of Science 2014-05-05 /pmc/articles/PMC4010516/ /pubmed/24797674 http://dx.doi.org/10.1371/journal.pone.0096661 Text en © 2014 Gupta et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Gupta, Preeti
Sidhartha, Elizabeth
Girard, Michael J. A.
Mari, Jean Martial
Wong, Tien-Yin
Cheng, Ching-Yu
A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title_full A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title_fullStr A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title_full_unstemmed A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title_short A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography
title_sort simplified method to measure choroidal thickness using adaptive compensation in enhanced depth imaging optical coherence tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4010516/
https://www.ncbi.nlm.nih.gov/pubmed/24797674
http://dx.doi.org/10.1371/journal.pone.0096661
work_keys_str_mv AT guptapreeti asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT sidharthaelizabeth asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT girardmichaelja asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT marijeanmartial asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT wongtienyin asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT chengchingyu asimplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT guptapreeti simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT sidharthaelizabeth simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT girardmichaelja simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT marijeanmartial simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT wongtienyin simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography
AT chengchingyu simplifiedmethodtomeasurechoroidalthicknessusingadaptivecompensationinenhanceddepthimagingopticalcoherencetomography