Cargando…

High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness

OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waive...

Descripción completa

Detalles Bibliográficos
Autores principales: Tamada, Tsutomu, Kanomata, Naoki, Sone, Teruki, Jo, Yoshimasa, Miyaji, Yoshiyuki, Higashi, Hiroki, Yamamoto, Akira, Ito, Katsuyoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4011860/
https://www.ncbi.nlm.nih.gov/pubmed/24802652
http://dx.doi.org/10.1371/journal.pone.0096619
_version_ 1782314856342355968
author Tamada, Tsutomu
Kanomata, Naoki
Sone, Teruki
Jo, Yoshimasa
Miyaji, Yoshiyuki
Higashi, Hiroki
Yamamoto, Akira
Ito, Katsuyoshi
author_facet Tamada, Tsutomu
Kanomata, Naoki
Sone, Teruki
Jo, Yoshimasa
Miyaji, Yoshiyuki
Higashi, Hiroki
Yamamoto, Akira
Ito, Katsuyoshi
author_sort Tamada, Tsutomu
collection PubMed
description OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm(2) and 0, 2000 s/mm(2)) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10(−3) mm(2)/s) of the tumor regions and normal regions were measured. RESULTS: Mean LCS and TNR at 0, 2000 s/mm(2) was significantly higher than those at 0, 1000 s/mm(2) (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm(2) was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm(2) (ρ = −0.602; p<0.001) and 0, 2000 s/mm(2) (ρ = −0.645; p<0.001). CONCLUSIONS: For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm(2) is more useful than b = 0, 1000 s/mm(2).
format Online
Article
Text
id pubmed-4011860
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-40118602014-05-09 High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness Tamada, Tsutomu Kanomata, Naoki Sone, Teruki Jo, Yoshimasa Miyaji, Yoshiyuki Higashi, Hiroki Yamamoto, Akira Ito, Katsuyoshi PLoS One Research Article OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm(2) and 0, 2000 s/mm(2)) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10(−3) mm(2)/s) of the tumor regions and normal regions were measured. RESULTS: Mean LCS and TNR at 0, 2000 s/mm(2) was significantly higher than those at 0, 1000 s/mm(2) (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm(2) was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm(2) (ρ = −0.602; p<0.001) and 0, 2000 s/mm(2) (ρ = −0.645; p<0.001). CONCLUSIONS: For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm(2) is more useful than b = 0, 1000 s/mm(2). Public Library of Science 2014-05-06 /pmc/articles/PMC4011860/ /pubmed/24802652 http://dx.doi.org/10.1371/journal.pone.0096619 Text en © 2014 Tamada et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Tamada, Tsutomu
Kanomata, Naoki
Sone, Teruki
Jo, Yoshimasa
Miyaji, Yoshiyuki
Higashi, Hiroki
Yamamoto, Akira
Ito, Katsuyoshi
High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title_full High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title_fullStr High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title_full_unstemmed High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title_short High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
title_sort high b value (2,000 s/mm(2)) diffusion-weighted magnetic resonance imaging in prostate cancer at 3 tesla: comparison with 1,000 s/mm(2) for tumor conspicuity and discrimination of aggressiveness
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4011860/
https://www.ncbi.nlm.nih.gov/pubmed/24802652
http://dx.doi.org/10.1371/journal.pone.0096619
work_keys_str_mv AT tamadatsutomu highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT kanomatanaoki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT soneteruki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT joyoshimasa highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT miyajiyoshiyuki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT higashihiroki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT yamamotoakira highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness
AT itokatsuyoshi highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness