Cargando…
High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness
OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waive...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4011860/ https://www.ncbi.nlm.nih.gov/pubmed/24802652 http://dx.doi.org/10.1371/journal.pone.0096619 |
_version_ | 1782314856342355968 |
---|---|
author | Tamada, Tsutomu Kanomata, Naoki Sone, Teruki Jo, Yoshimasa Miyaji, Yoshiyuki Higashi, Hiroki Yamamoto, Akira Ito, Katsuyoshi |
author_facet | Tamada, Tsutomu Kanomata, Naoki Sone, Teruki Jo, Yoshimasa Miyaji, Yoshiyuki Higashi, Hiroki Yamamoto, Akira Ito, Katsuyoshi |
author_sort | Tamada, Tsutomu |
collection | PubMed |
description | OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm(2) and 0, 2000 s/mm(2)) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10(−3) mm(2)/s) of the tumor regions and normal regions were measured. RESULTS: Mean LCS and TNR at 0, 2000 s/mm(2) was significantly higher than those at 0, 1000 s/mm(2) (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm(2) was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm(2) (ρ = −0.602; p<0.001) and 0, 2000 s/mm(2) (ρ = −0.645; p<0.001). CONCLUSIONS: For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm(2) is more useful than b = 0, 1000 s/mm(2). |
format | Online Article Text |
id | pubmed-4011860 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40118602014-05-09 High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness Tamada, Tsutomu Kanomata, Naoki Sone, Teruki Jo, Yoshimasa Miyaji, Yoshiyuki Higashi, Hiroki Yamamoto, Akira Ito, Katsuyoshi PLoS One Research Article OBJECTIVE: The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm(2) and 0, 2000 s/mm(2)) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10(−3) mm(2)/s) of the tumor regions and normal regions were measured. RESULTS: Mean LCS and TNR at 0, 2000 s/mm(2) was significantly higher than those at 0, 1000 s/mm(2) (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm(2) was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm(2) (ρ = −0.602; p<0.001) and 0, 2000 s/mm(2) (ρ = −0.645; p<0.001). CONCLUSIONS: For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm(2) is more useful than b = 0, 1000 s/mm(2). Public Library of Science 2014-05-06 /pmc/articles/PMC4011860/ /pubmed/24802652 http://dx.doi.org/10.1371/journal.pone.0096619 Text en © 2014 Tamada et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Tamada, Tsutomu Kanomata, Naoki Sone, Teruki Jo, Yoshimasa Miyaji, Yoshiyuki Higashi, Hiroki Yamamoto, Akira Ito, Katsuyoshi High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title | High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title_full | High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title_fullStr | High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title_full_unstemmed | High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title_short | High b Value (2,000 s/mm(2)) Diffusion-Weighted Magnetic Resonance Imaging in Prostate Cancer at 3 Tesla: Comparison with 1,000 s/mm(2) for Tumor Conspicuity and Discrimination of Aggressiveness |
title_sort | high b value (2,000 s/mm(2)) diffusion-weighted magnetic resonance imaging in prostate cancer at 3 tesla: comparison with 1,000 s/mm(2) for tumor conspicuity and discrimination of aggressiveness |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4011860/ https://www.ncbi.nlm.nih.gov/pubmed/24802652 http://dx.doi.org/10.1371/journal.pone.0096619 |
work_keys_str_mv | AT tamadatsutomu highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT kanomatanaoki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT soneteruki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT joyoshimasa highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT miyajiyoshiyuki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT higashihiroki highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT yamamotoakira highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness AT itokatsuyoshi highbvalue2000smm2diffusionweightedmagneticresonanceimaginginprostatecancerat3teslacomparisonwith1000smm2fortumorconspicuityanddiscriminationofaggressiveness |