Cargando…

Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma

Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volume...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Qun, Lin, Shi-Rong, He, Fang, Kang, De-Hua, Chen, Guo-Zhang, Luo, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sun Yat-sen University Cancer Center 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013302/
https://www.ncbi.nlm.nih.gov/pubmed/22035860
http://dx.doi.org/10.5732/cjc.011.10168
_version_ 1782315026620612608
author Zhang, Qun
Lin, Shi-Rong
He, Fang
Kang, De-Hua
Chen, Guo-Zhang
Luo, Wei
author_facet Zhang, Qun
Lin, Shi-Rong
He, Fang
Kang, De-Hua
Chen, Guo-Zhang
Luo, Wei
author_sort Zhang, Qun
collection PubMed
description Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D(98)) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.
format Online
Article
Text
id pubmed-4013302
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Sun Yat-sen University Cancer Center
record_format MEDLINE/PubMed
spelling pubmed-40133022014-05-15 Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma Zhang, Qun Lin, Shi-Rong He, Fang Kang, De-Hua Chen, Guo-Zhang Luo, Wei Chin J Cancer Technology and Method Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D(98)) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes. Sun Yat-sen University Cancer Center 2011-11 /pmc/articles/PMC4013302/ /pubmed/22035860 http://dx.doi.org/10.5732/cjc.011.10168 Text en Chinese Journal of Cancer http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License, which allows readers to alter, transform, or build upon the article and then distribute the resulting work under the same or similar license to this one. The work must be attributed back to the original author and commercial use is not permitted without specific permission.
spellingShingle Technology and Method
Zhang, Qun
Lin, Shi-Rong
He, Fang
Kang, De-Hua
Chen, Guo-Zhang
Luo, Wei
Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title_full Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title_fullStr Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title_full_unstemmed Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title_short Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
title_sort water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
topic Technology and Method
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013302/
https://www.ncbi.nlm.nih.gov/pubmed/22035860
http://dx.doi.org/10.5732/cjc.011.10168
work_keys_str_mv AT zhangqun waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma
AT linshirong waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma
AT hefang waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma
AT kangdehua waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma
AT chenguozhang waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma
AT luowei waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma