Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma
Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volume...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sun Yat-sen University Cancer Center
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013302/ https://www.ncbi.nlm.nih.gov/pubmed/22035860 http://dx.doi.org/10.5732/cjc.011.10168 |
_version_ | 1782315026620612608 |
---|---|
author | Zhang, Qun Lin, Shi-Rong He, Fang Kang, De-Hua Chen, Guo-Zhang Luo, Wei |
author_facet | Zhang, Qun Lin, Shi-Rong He, Fang Kang, De-Hua Chen, Guo-Zhang Luo, Wei |
author_sort | Zhang, Qun |
collection | PubMed |
description | Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D(98)) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes. |
format | Online Article Text |
id | pubmed-4013302 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Sun Yat-sen University Cancer Center |
record_format | MEDLINE/PubMed |
spelling | pubmed-40133022014-05-15 Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma Zhang, Qun Lin, Shi-Rong He, Fang Kang, De-Hua Chen, Guo-Zhang Luo, Wei Chin J Cancer Technology and Method Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D(98)) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes. Sun Yat-sen University Cancer Center 2011-11 /pmc/articles/PMC4013302/ /pubmed/22035860 http://dx.doi.org/10.5732/cjc.011.10168 Text en Chinese Journal of Cancer http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License, which allows readers to alter, transform, or build upon the article and then distribute the resulting work under the same or similar license to this one. The work must be attributed back to the original author and commercial use is not permitted without specific permission. |
spellingShingle | Technology and Method Zhang, Qun Lin, Shi-Rong He, Fang Kang, De-Hua Chen, Guo-Zhang Luo, Wei Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title | Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title_full | Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title_fullStr | Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title_full_unstemmed | Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title_short | Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
title_sort | water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma |
topic | Technology and Method |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013302/ https://www.ncbi.nlm.nih.gov/pubmed/22035860 http://dx.doi.org/10.5732/cjc.011.10168 |
work_keys_str_mv | AT zhangqun waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma AT linshirong waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma AT hefang waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma AT kangdehua waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma AT chenguozhang waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma AT luowei waterfilledballooninthepostoperativeresectioncavityimprovesdosedistributiontotargetvolumesinradiotherapyofmaxillarysinuscarcinoma |