Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis

The overproduction of reactive oxygen and nitrogen species (ROS and RNS) can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine re...

Descripción completa

Detalles Bibliográficos
Autores principales: Seeley, Kent W., Fertig, Alison R., Dufresne, Craig P., Pinho, Joao P. C., Stevens, Stanley M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013627/
https://www.ncbi.nlm.nih.gov/pubmed/24736779
http://dx.doi.org/10.3390/ijms15046265
_version_ 1782315088202432512
author Seeley, Kent W.
Fertig, Alison R.
Dufresne, Craig P.
Pinho, Joao P. C.
Stevens, Stanley M.
author_facet Seeley, Kent W.
Fertig, Alison R.
Dufresne, Craig P.
Pinho, Joao P. C.
Stevens, Stanley M.
author_sort Seeley, Kent W.
collection PubMed
description The overproduction of reactive oxygen and nitrogen species (ROS and RNS) can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine residues to form nitrotyrosine, and to date, the identification of nitrotyrosine sites in proteins continues to be a major analytical challenge. We have developed a method by which (15)N-labeled nitrotyrosine groups are generated on peptide or protein standards using stable isotope-labeled peroxynitrite (O(15)NOO(−)), and the resulting standard is mixed with representative samples in which nitrotyrosine formation is to be measured by mass spectrometry (MS). Nitropeptide MS/MS spectra are filtered using high mass accuracy Fourier transform MS (FTMS) detection of the nitrotyrosine immonium ion. Given that the nitropeptide pair is co-isolated for MS/MS fragmentation, the nitrotyrosine immonium ions (at m/z = 181 or 182) can be used for relative quantitation with negligible isotopic interference at a mass resolution of greater than 50,000 (FWHM, full width at half-maximum). Furthermore, the standard potentially allows for the increased signal of nitrotyrosine-containing peptides, thus facilitating selection for MS/MS in a data-dependent mode of acquisition. We have evaluated the methodology in terms of nitrotyrosine site identification and relative quantitation using nitrated peptide and protein standards.
format Online
Article
Text
id pubmed-4013627
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-40136272014-05-08 Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis Seeley, Kent W. Fertig, Alison R. Dufresne, Craig P. Pinho, Joao P. C. Stevens, Stanley M. Int J Mol Sci Article The overproduction of reactive oxygen and nitrogen species (ROS and RNS) can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine residues to form nitrotyrosine, and to date, the identification of nitrotyrosine sites in proteins continues to be a major analytical challenge. We have developed a method by which (15)N-labeled nitrotyrosine groups are generated on peptide or protein standards using stable isotope-labeled peroxynitrite (O(15)NOO(−)), and the resulting standard is mixed with representative samples in which nitrotyrosine formation is to be measured by mass spectrometry (MS). Nitropeptide MS/MS spectra are filtered using high mass accuracy Fourier transform MS (FTMS) detection of the nitrotyrosine immonium ion. Given that the nitropeptide pair is co-isolated for MS/MS fragmentation, the nitrotyrosine immonium ions (at m/z = 181 or 182) can be used for relative quantitation with negligible isotopic interference at a mass resolution of greater than 50,000 (FWHM, full width at half-maximum). Furthermore, the standard potentially allows for the increased signal of nitrotyrosine-containing peptides, thus facilitating selection for MS/MS in a data-dependent mode of acquisition. We have evaluated the methodology in terms of nitrotyrosine site identification and relative quantitation using nitrated peptide and protein standards. Molecular Diversity Preservation International (MDPI) 2014-04-14 /pmc/articles/PMC4013627/ /pubmed/24736779 http://dx.doi.org/10.3390/ijms15046265 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland http://creativecommons.org/licenses/by/3.0/ This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Seeley, Kent W.
Fertig, Alison R.
Dufresne, Craig P.
Pinho, Joao P. C.
Stevens, Stanley M.
Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title_full Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title_fullStr Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title_full_unstemmed Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title_short Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis
title_sort evaluation of a method for nitrotyrosine site identification and relative quantitation using a stable isotope-labeled nitrated spike-in standard and high resolution fourier transform ms and ms/ms analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4013627/
https://www.ncbi.nlm.nih.gov/pubmed/24736779
http://dx.doi.org/10.3390/ijms15046265
work_keys_str_mv AT seeleykentw evaluationofamethodfornitrotyrosinesiteidentificationandrelativequantitationusingastableisotopelabelednitratedspikeinstandardandhighresolutionfouriertransformmsandmsmsanalysis
AT fertigalisonr evaluationofamethodfornitrotyrosinesiteidentificationandrelativequantitationusingastableisotopelabelednitratedspikeinstandardandhighresolutionfouriertransformmsandmsmsanalysis
AT dufresnecraigp evaluationofamethodfornitrotyrosinesiteidentificationandrelativequantitationusingastableisotopelabelednitratedspikeinstandardandhighresolutionfouriertransformmsandmsmsanalysis
AT pinhojoaopc evaluationofamethodfornitrotyrosinesiteidentificationandrelativequantitationusingastableisotopelabelednitratedspikeinstandardandhighresolutionfouriertransformmsandmsmsanalysis
AT stevensstanleym evaluationofamethodfornitrotyrosinesiteidentificationandrelativequantitationusingastableisotopelabelednitratedspikeinstandardandhighresolutionfouriertransformmsandmsmsanalysis