Cargando…
Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure
Objective To assess the potential contribution of unmeasured general health status to patient selection in assessments of the clinical effectiveness of implantable cardioverter-defibrillator (ICD) therapy. Design Retrospective cohort study. Setting Linked data from an ICD registry, heart failure reg...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group Ltd.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014056/ https://www.ncbi.nlm.nih.gov/pubmed/24812112 http://dx.doi.org/10.1136/bmj.g2866 |
_version_ | 1782315133760962560 |
---|---|
author | Setoguchi, Soko Warner Stevenson, Lynne Stewart, Garrick C Bhatt, Deepak L Epstein, Andrew E Desai, Manisha Williams, Lauren A Chen, Chih-Ying |
author_facet | Setoguchi, Soko Warner Stevenson, Lynne Stewart, Garrick C Bhatt, Deepak L Epstein, Andrew E Desai, Manisha Williams, Lauren A Chen, Chih-Ying |
author_sort | Setoguchi, Soko |
collection | PubMed |
description | Objective To assess the potential contribution of unmeasured general health status to patient selection in assessments of the clinical effectiveness of implantable cardioverter-defibrillator (ICD) therapy. Design Retrospective cohort study. Setting Linked data from an ICD registry, heart failure registry, and Medicare claims data for ICDs implanted in 2005 through 2009. Participants 29 426 patients admitted to hospital with heart failure aged 66 years or older and eligible for ICD therapy for primary prevention. Main outcome measures Non-traumatic hip fracture, admission to a skilled nursing facility, and 30 day mortality—outcomes unlikely to be improved by ICD therapy. Results Compared with 17 853 patients without ICD therapy, 11 573 patients with ICD therapy were younger and had lower ejection fraction and more cardiac admissions to hospital but fewer non-cardiac admissions to hospital and comorbid conditions. Patients with ICD therapy had greater freedom from unrelated events after adjusting for age and sex: hip fracture (hazard ratio 0.77, 95% confidence interval 0.64 to 0.92), skilled nursing facility admission (0.53, 0.50 to 0.55), and 30 day mortality (0.12, 0.10 to 0.15). Conclusions Lower risks of measured outcomes likely reflect unmeasured differences in comorbidity and frailty. The findings highlight potential pitfalls of observational comparative effectiveness research and support physician consideration of general health status in selecting patients for ICD therapy. |
format | Online Article Text |
id | pubmed-4014056 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BMJ Publishing Group Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-40140562014-05-13 Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure Setoguchi, Soko Warner Stevenson, Lynne Stewart, Garrick C Bhatt, Deepak L Epstein, Andrew E Desai, Manisha Williams, Lauren A Chen, Chih-Ying BMJ Research Objective To assess the potential contribution of unmeasured general health status to patient selection in assessments of the clinical effectiveness of implantable cardioverter-defibrillator (ICD) therapy. Design Retrospective cohort study. Setting Linked data from an ICD registry, heart failure registry, and Medicare claims data for ICDs implanted in 2005 through 2009. Participants 29 426 patients admitted to hospital with heart failure aged 66 years or older and eligible for ICD therapy for primary prevention. Main outcome measures Non-traumatic hip fracture, admission to a skilled nursing facility, and 30 day mortality—outcomes unlikely to be improved by ICD therapy. Results Compared with 17 853 patients without ICD therapy, 11 573 patients with ICD therapy were younger and had lower ejection fraction and more cardiac admissions to hospital but fewer non-cardiac admissions to hospital and comorbid conditions. Patients with ICD therapy had greater freedom from unrelated events after adjusting for age and sex: hip fracture (hazard ratio 0.77, 95% confidence interval 0.64 to 0.92), skilled nursing facility admission (0.53, 0.50 to 0.55), and 30 day mortality (0.12, 0.10 to 0.15). Conclusions Lower risks of measured outcomes likely reflect unmeasured differences in comorbidity and frailty. The findings highlight potential pitfalls of observational comparative effectiveness research and support physician consideration of general health status in selecting patients for ICD therapy. BMJ Publishing Group Ltd. 2014-05-08 /pmc/articles/PMC4014056/ /pubmed/24812112 http://dx.doi.org/10.1136/bmj.g2866 Text en © Setoguchi et al 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/3.0/. |
spellingShingle | Research Setoguchi, Soko Warner Stevenson, Lynne Stewart, Garrick C Bhatt, Deepak L Epstein, Andrew E Desai, Manisha Williams, Lauren A Chen, Chih-Ying Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title | Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title_full | Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title_fullStr | Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title_full_unstemmed | Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title_short | Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
title_sort | influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014056/ https://www.ncbi.nlm.nih.gov/pubmed/24812112 http://dx.doi.org/10.1136/bmj.g2866 |
work_keys_str_mv | AT setoguchisoko influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT warnerstevensonlynne influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT stewartgarrickc influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT bhattdeepakl influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT epsteinandrewe influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT desaimanisha influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT williamslaurena influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure AT chenchihying influenceofhealthycandidatebiasinassessingclinicaleffectivenessforimplantablecardioverterdefibrillatorscohortstudyofolderpatientswithheartfailure |