Cargando…
Ion Sponge: A 3-Dimentional Array of Quadrupole Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas Phase
[Image: see text] In this study, the concept of ion sponge has been explored for developing 3D arrays of large numbers of ion traps but with simple configurations. An ion sponge device with 484 trapping units in a volume of 10 × 10 × 3.2 cm has been constructed by simply stacking 9 meshes together....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American
Chemical
Society
2014
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014143/ https://www.ncbi.nlm.nih.gov/pubmed/24758328 http://dx.doi.org/10.1021/ac5008046 |
_version_ | 1782315141441781760 |
---|---|
author | Xu, Wei Li, Linfan Zhou, Xiaoyu Ouyang, Zheng |
author_facet | Xu, Wei Li, Linfan Zhou, Xiaoyu Ouyang, Zheng |
author_sort | Xu, Wei |
collection | PubMed |
description | [Image: see text] In this study, the concept of ion sponge has been explored for developing 3D arrays of large numbers of ion traps but with simple configurations. An ion sponge device with 484 trapping units in a volume of 10 × 10 × 3.2 cm has been constructed by simply stacking 9 meshes together. A single rf was used for trapping ions and mass-selective ion processing. The ion sponge provides a large trapping capacity and is highly transparent for transfer of ions, neutrals, and photons for gas phase ion processing. Multiple layers of quadrupole ion traps, with 121 trapping units in each layer, can operate as a single device for MS or MS/MS analysis, or as a series of mass-selective trapping devices with interlayer ion transfers facilitated by AC and DC voltages. Automatic sorting of ions to different trapping layers based on their mass-to-charge (m/z) ratios was achieved with traps of different sizes. Tandem-in-space MS/MS has also been demonstrated with precursor ions and fragment ions trapped in separate locations. |
format | Online Article Text |
id | pubmed-4014143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | American
Chemical
Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-40141432015-04-23 Ion Sponge: A 3-Dimentional Array of Quadrupole Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas Phase Xu, Wei Li, Linfan Zhou, Xiaoyu Ouyang, Zheng Anal Chem [Image: see text] In this study, the concept of ion sponge has been explored for developing 3D arrays of large numbers of ion traps but with simple configurations. An ion sponge device with 484 trapping units in a volume of 10 × 10 × 3.2 cm has been constructed by simply stacking 9 meshes together. A single rf was used for trapping ions and mass-selective ion processing. The ion sponge provides a large trapping capacity and is highly transparent for transfer of ions, neutrals, and photons for gas phase ion processing. Multiple layers of quadrupole ion traps, with 121 trapping units in each layer, can operate as a single device for MS or MS/MS analysis, or as a series of mass-selective trapping devices with interlayer ion transfers facilitated by AC and DC voltages. Automatic sorting of ions to different trapping layers based on their mass-to-charge (m/z) ratios was achieved with traps of different sizes. Tandem-in-space MS/MS has also been demonstrated with precursor ions and fragment ions trapped in separate locations. American Chemical Society 2014-04-23 2014-05-06 /pmc/articles/PMC4014143/ /pubmed/24758328 http://dx.doi.org/10.1021/ac5008046 Text en Copyright © 2014 American Chemical Society |
spellingShingle | Xu, Wei Li, Linfan Zhou, Xiaoyu Ouyang, Zheng Ion Sponge: A 3-Dimentional Array of Quadrupole Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas Phase |
title | Ion Sponge: A 3-Dimentional Array of Quadrupole
Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas
Phase |
title_full | Ion Sponge: A 3-Dimentional Array of Quadrupole
Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas
Phase |
title_fullStr | Ion Sponge: A 3-Dimentional Array of Quadrupole
Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas
Phase |
title_full_unstemmed | Ion Sponge: A 3-Dimentional Array of Quadrupole
Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas
Phase |
title_short | Ion Sponge: A 3-Dimentional Array of Quadrupole
Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas
Phase |
title_sort | ion sponge: a 3-dimentional array of quadrupole
ion traps for trapping and mass-selectively processing ions in gas
phase |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014143/ https://www.ncbi.nlm.nih.gov/pubmed/24758328 http://dx.doi.org/10.1021/ac5008046 |
work_keys_str_mv | AT xuwei ionspongea3dimentionalarrayofquadrupoleiontrapsfortrappingandmassselectivelyprocessingionsingasphase AT lilinfan ionspongea3dimentionalarrayofquadrupoleiontrapsfortrappingandmassselectivelyprocessingionsingasphase AT zhouxiaoyu ionspongea3dimentionalarrayofquadrupoleiontrapsfortrappingandmassselectivelyprocessingionsingasphase AT ouyangzheng ionspongea3dimentionalarrayofquadrupoleiontrapsfortrappingandmassselectivelyprocessingionsingasphase |