Cargando…
Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702)
A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy o...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014158/ https://www.ncbi.nlm.nih.gov/pubmed/24385469 http://dx.doi.org/10.1093/jrr/rrt135 |
_version_ | 1782315144956608512 |
---|---|
author | Nishio, Teiji Shirato, Hiroki Ishikawa, Masayori Miyabe, Yuki Kito, Satoshi Narita, Yuichirou Onimaru, Rikiya Ishikura, Satoshi Ito, Yoshinori Hiraoka, Masahiro |
author_facet | Nishio, Teiji Shirato, Hiroki Ishikawa, Masayori Miyabe, Yuki Kito, Satoshi Narita, Yuichirou Onimaru, Rikiya Ishikura, Satoshi Ito, Yoshinori Hiraoka, Masahiro |
author_sort | Nishio, Teiji |
collection | PubMed |
description | A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated. |
format | Online Article Text |
id | pubmed-4014158 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-40141582014-05-12 Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) Nishio, Teiji Shirato, Hiroki Ishikawa, Masayori Miyabe, Yuki Kito, Satoshi Narita, Yuichirou Onimaru, Rikiya Ishikura, Satoshi Ito, Yoshinori Hiraoka, Masahiro J Radiat Res Technology A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated. Oxford University Press 2014-05 2014-01-01 /pmc/articles/PMC4014158/ /pubmed/24385469 http://dx.doi.org/10.1093/jrr/rrt135 Text en © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Technology Nishio, Teiji Shirato, Hiroki Ishikawa, Masayori Miyabe, Yuki Kito, Satoshi Narita, Yuichirou Onimaru, Rikiya Ishikura, Satoshi Ito, Yoshinori Hiraoka, Masahiro Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title | Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title_full | Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title_fullStr | Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title_full_unstemmed | Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title_short | Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702) |
title_sort | design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase i study of stereotactic body radiation therapy in patients with t2n0m0 non-small cell lung cancer: japan clinical oncology group trial (jcog0702) |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014158/ https://www.ncbi.nlm.nih.gov/pubmed/24385469 http://dx.doi.org/10.1093/jrr/rrt135 |
work_keys_str_mv | AT nishioteiji designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT shiratohiroki designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT ishikawamasayori designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT miyabeyuki designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT kitosatoshi designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT naritayuichirou designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT onimarurikiya designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT ishikurasatoshi designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT itoyoshinori designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 AT hiraokamasahiro designdevelopmentofwatertanktypelungphantomanddosimetricverificationininstitutionsparticipatinginaphaseistudyofstereotacticbodyradiationtherapyinpatientswitht2n0m0nonsmallcelllungcancerjapanclinicaloncologygrouptrialjcog0702 |