Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?

The continuous glucose monitoring system (CGM) has been used for constant checking of glucose level by measuring interstitial glucose concentrations, since the early days of the 21st century. It can potentially improve diabetes care if used carefully with the understanding of the characteristics of...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Junko, Hirose, Takahisa, Watada, Hirotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014941/
https://www.ncbi.nlm.nih.gov/pubmed/24843568
http://dx.doi.org/10.1111/j.2040-1124.2012.00197.x
_version_ 1782315263287361536
author Sato, Junko
Hirose, Takahisa
Watada, Hirotaka
author_facet Sato, Junko
Hirose, Takahisa
Watada, Hirotaka
author_sort Sato, Junko
collection PubMed
description The continuous glucose monitoring system (CGM) has been used for constant checking of glucose level by measuring interstitial glucose concentrations, since the early days of the 21st century. It can potentially improve diabetes care if used carefully with the understanding of the characteristics of this system. Although there is a time lag of approximately 5–15 min between blood and interstitial glucose levels, the system is considered the most suitable device for meticulous glucose control and prevention of hypoglycemia. A large number of studies have examined its accuracy, safety and clinical effectiveness. The continuous glucose‐error grid analysis (CG‐EGA), designed by WL Clarke, evaluates the clinical accuracy of CGM. It examines ‘temporal’ characteristics of the data, analyzing pairs of reference and sensor readings as a process in time represented by a ‘bidimensional’ time series and taking into account inherent physiological time lags. Investment in CG‐EGA is clearly meaningful, even though there are other methodologies for evaluation. The use of each method complementarily is the most effective way to prove the accuracy of the device. The device has improved gradually, and real‐time CGM, which allows real‐time monitoring of blood glucose level, is already available commercially. The use of real‐time CGM could potentially lead to over‐ or undertreatment with insulin. Patient education through proper and effective handling of the new device is essential to improve diabetes care. (J Diabetes Invest, doi: 10.1111/j.2040‐1124.2012.00197.x, 2012)
format Online
Article
Text
id pubmed-4014941
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-40149412014-05-19 Continuous glucose monitoring system: Is it really accurate, safe and clinically useful? Sato, Junko Hirose, Takahisa Watada, Hirotaka J Diabetes Investig Review Articles The continuous glucose monitoring system (CGM) has been used for constant checking of glucose level by measuring interstitial glucose concentrations, since the early days of the 21st century. It can potentially improve diabetes care if used carefully with the understanding of the characteristics of this system. Although there is a time lag of approximately 5–15 min between blood and interstitial glucose levels, the system is considered the most suitable device for meticulous glucose control and prevention of hypoglycemia. A large number of studies have examined its accuracy, safety and clinical effectiveness. The continuous glucose‐error grid analysis (CG‐EGA), designed by WL Clarke, evaluates the clinical accuracy of CGM. It examines ‘temporal’ characteristics of the data, analyzing pairs of reference and sensor readings as a process in time represented by a ‘bidimensional’ time series and taking into account inherent physiological time lags. Investment in CG‐EGA is clearly meaningful, even though there are other methodologies for evaluation. The use of each method complementarily is the most effective way to prove the accuracy of the device. The device has improved gradually, and real‐time CGM, which allows real‐time monitoring of blood glucose level, is already available commercially. The use of real‐time CGM could potentially lead to over‐ or undertreatment with insulin. Patient education through proper and effective handling of the new device is essential to improve diabetes care. (J Diabetes Invest, doi: 10.1111/j.2040‐1124.2012.00197.x, 2012) Blackwell Publishing Ltd 2012-06-06 2012-02-17 /pmc/articles/PMC4014941/ /pubmed/24843568 http://dx.doi.org/10.1111/j.2040-1124.2012.00197.x Text en © 2012 Asian Association for the Study of Diabetes and Blackwell Publishing Asia Pty Ltd
spellingShingle Review Articles
Sato, Junko
Hirose, Takahisa
Watada, Hirotaka
Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title_full Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title_fullStr Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title_full_unstemmed Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title_short Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
title_sort continuous glucose monitoring system: is it really accurate, safe and clinically useful?
topic Review Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014941/
https://www.ncbi.nlm.nih.gov/pubmed/24843568
http://dx.doi.org/10.1111/j.2040-1124.2012.00197.x
work_keys_str_mv AT satojunko continuousglucosemonitoringsystemisitreallyaccuratesafeandclinicallyuseful
AT hirosetakahisa continuousglucosemonitoringsystemisitreallyaccuratesafeandclinicallyuseful
AT watadahirotaka continuousglucosemonitoringsystemisitreallyaccuratesafeandclinicallyuseful