Cargando…
Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids
BACKGROUND: Levofloxacin hemihydrate (LEV) and ambroxol HCl (AMB) are available for the treatment of upper and lower respiratory tract infections. A survey of the literature reveals that two reversed phase HPLC methods were e reported for the simultaneous determination of LEV and AMB in pharmaceutic...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4015170/ https://www.ncbi.nlm.nih.gov/pubmed/24079576 http://dx.doi.org/10.1186/1752-153X-7-162 |
_version_ | 1782315293236789248 |
---|---|
author | Belal, Fathalla F Sharaf El-Din, Mohie K El-Enany, Nahed M Saad, Samar |
author_facet | Belal, Fathalla F Sharaf El-Din, Mohie K El-Enany, Nahed M Saad, Samar |
author_sort | Belal, Fathalla F |
collection | PubMed |
description | BACKGROUND: Levofloxacin hemihydrate (LEV) and ambroxol HCl (AMB) are available for the treatment of upper and lower respiratory tract infections. A survey of the literature reveals that two reversed phase HPLC methods were e reported for the simultaneous determination of LEV and AMB in pharmaceutical preparations. However the reported methods suffers from the low sensitivity, no application of the method in the combined tablets and no application to biological fluids. Also the toxic effects of the used solvents which are harmful to human beings. For this reason, our target was to develop a simple sensitive, less hazardous micellar HPLC method for the simultaneous determination of LEV and AMB in their combined dosage forms and plasma. RESULTS: The method showed good linearity over the ranges of 1–44 μg/mL and 1–20 μg/mL with limits of detection 0.26 and 0.07 μg/mL and limits of quantification 0.80 and 0.20 μg/mL for LEV and AMB, respectively. The method was further extended to the determination of LEV in spiked human plasma with mean percentage recoveries of 100.10% ± 1.14 as well as determination of LEV in real human plasma without prior extraction. Statistical evaluation of the data was performed according to ICH Guidelines. CONCLUSION: The suggested method was successfully applied for the simultaneous analysis of the studied drugs in their co-formulated tablets and human plasma. The mean percentage recoveries in combined tablets were 100.20 ± 1.64 and 100.72 ± 1.11 for LEV and AMB, respectively and 100.10 ± 1.14 for LEV in spiked human plasma. Statistical comparison of the results with those of the comparison method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. |
format | Online Article Text |
id | pubmed-4015170 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-40151702014-05-23 Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids Belal, Fathalla F Sharaf El-Din, Mohie K El-Enany, Nahed M Saad, Samar Chem Cent J Research Article BACKGROUND: Levofloxacin hemihydrate (LEV) and ambroxol HCl (AMB) are available for the treatment of upper and lower respiratory tract infections. A survey of the literature reveals that two reversed phase HPLC methods were e reported for the simultaneous determination of LEV and AMB in pharmaceutical preparations. However the reported methods suffers from the low sensitivity, no application of the method in the combined tablets and no application to biological fluids. Also the toxic effects of the used solvents which are harmful to human beings. For this reason, our target was to develop a simple sensitive, less hazardous micellar HPLC method for the simultaneous determination of LEV and AMB in their combined dosage forms and plasma. RESULTS: The method showed good linearity over the ranges of 1–44 μg/mL and 1–20 μg/mL with limits of detection 0.26 and 0.07 μg/mL and limits of quantification 0.80 and 0.20 μg/mL for LEV and AMB, respectively. The method was further extended to the determination of LEV in spiked human plasma with mean percentage recoveries of 100.10% ± 1.14 as well as determination of LEV in real human plasma without prior extraction. Statistical evaluation of the data was performed according to ICH Guidelines. CONCLUSION: The suggested method was successfully applied for the simultaneous analysis of the studied drugs in their co-formulated tablets and human plasma. The mean percentage recoveries in combined tablets were 100.20 ± 1.64 and 100.72 ± 1.11 for LEV and AMB, respectively and 100.10 ± 1.14 for LEV in spiked human plasma. Statistical comparison of the results with those of the comparison method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. BioMed Central 2013-10-01 /pmc/articles/PMC4015170/ /pubmed/24079576 http://dx.doi.org/10.1186/1752-153X-7-162 Text en Copyright © 2013 Belal et al.; licensee Chemistry Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Belal, Fathalla F Sharaf El-Din, Mohie K El-Enany, Nahed M Saad, Samar Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title | Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title_full | Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title_fullStr | Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title_full_unstemmed | Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title_short | Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids |
title_sort | micellar liquid chromatographic method for the simultaneous determination of levofloxacin and ambroxol in combined tablets: application to biological fluids |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4015170/ https://www.ncbi.nlm.nih.gov/pubmed/24079576 http://dx.doi.org/10.1186/1752-153X-7-162 |
work_keys_str_mv | AT belalfathallaf micellarliquidchromatographicmethodforthesimultaneousdeterminationoflevofloxacinandambroxolincombinedtabletsapplicationtobiologicalfluids AT sharafeldinmohiek micellarliquidchromatographicmethodforthesimultaneousdeterminationoflevofloxacinandambroxolincombinedtabletsapplicationtobiologicalfluids AT elenanynahedm micellarliquidchromatographicmethodforthesimultaneousdeterminationoflevofloxacinandambroxolincombinedtabletsapplicationtobiologicalfluids AT saadsamar micellarliquidchromatographicmethodforthesimultaneousdeterminationoflevofloxacinandambroxolincombinedtabletsapplicationtobiologicalfluids |