Cargando…
Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1
AIM: The aim of this survey was to compare four DNA extraction methods from Iranian sheep strain E.granulosus isolates. BACKGROUND: Cystic echinococcosis (CE) caused by the metacestode of the dog tapeworm Echinococcus spp., is a global zoonotic infection which is economically important and constitut...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Research Institute for Gastroenterology and Liver Diseases
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4017407/ https://www.ncbi.nlm.nih.gov/pubmed/24834163 |
_version_ | 1782479944969879552 |
---|---|
author | Nejad, Mohammad Rostami Roshani, Mohammad Lahmi, Farhad Mojarad, Ehsan Nazemalhosseini |
author_facet | Nejad, Mohammad Rostami Roshani, Mohammad Lahmi, Farhad Mojarad, Ehsan Nazemalhosseini |
author_sort | Nejad, Mohammad Rostami |
collection | PubMed |
description | AIM: The aim of this survey was to compare four DNA extraction methods from Iranian sheep strain E.granulosus isolates. BACKGROUND: Cystic echinococcosis (CE) caused by the metacestode of the dog tapeworm Echinococcus spp., is a global zoonotic infection which is economically important and constitutes a major threat to public health in many countries. Strains characterization is essential for the establishment of a preventive and control strategy in every endemic area. PATIENTS AND METHODS: Forty five infected organs from cattle, sheep and goat were collected from different abattoirs of Iran. All cysts were examined by microscopic observation of protoscoleces. For each cyst, protoscoleces were aspirated and DNA of each cyst was extracted with 4 different methods including tissue Kit extraction, modified Cinnagen extraction kit, Phenol-chloroform (Sambrook1999) and modified Phenol chloroform methods. Efficiency of the DNA was determined by degree of success in PCR amplification. RESULTS: Cinnagen modified extraction and modified Phenol chloroform methods were equally effective and superior to other methods after DNA electrophoresis and PCR reaction. Inhibition was observed in PCR with DNA isolated from protoscoleces, and a 1/100 dilution was able to alleviate this problem with DNA extracted. CONCLUSION: The result of this study show that the quality of extracted DNA using modified Cinnagen extraction kit and modified phenol–chloroform are very high and gave identical results after RCR reaction using 12S rRNA gene. Further evaluation is required for its utilization in other clinical specimens. |
format | Online Article Text |
id | pubmed-4017407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Research Institute for Gastroenterology and Liver Diseases |
record_format | MEDLINE/PubMed |
spelling | pubmed-40174072014-05-15 Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 Nejad, Mohammad Rostami Roshani, Mohammad Lahmi, Farhad Mojarad, Ehsan Nazemalhosseini Gastroenterol Hepatol Bed Bench Original Article AIM: The aim of this survey was to compare four DNA extraction methods from Iranian sheep strain E.granulosus isolates. BACKGROUND: Cystic echinococcosis (CE) caused by the metacestode of the dog tapeworm Echinococcus spp., is a global zoonotic infection which is economically important and constitutes a major threat to public health in many countries. Strains characterization is essential for the establishment of a preventive and control strategy in every endemic area. PATIENTS AND METHODS: Forty five infected organs from cattle, sheep and goat were collected from different abattoirs of Iran. All cysts were examined by microscopic observation of protoscoleces. For each cyst, protoscoleces were aspirated and DNA of each cyst was extracted with 4 different methods including tissue Kit extraction, modified Cinnagen extraction kit, Phenol-chloroform (Sambrook1999) and modified Phenol chloroform methods. Efficiency of the DNA was determined by degree of success in PCR amplification. RESULTS: Cinnagen modified extraction and modified Phenol chloroform methods were equally effective and superior to other methods after DNA electrophoresis and PCR reaction. Inhibition was observed in PCR with DNA isolated from protoscoleces, and a 1/100 dilution was able to alleviate this problem with DNA extracted. CONCLUSION: The result of this study show that the quality of extracted DNA using modified Cinnagen extraction kit and modified phenol–chloroform are very high and gave identical results after RCR reaction using 12S rRNA gene. Further evaluation is required for its utilization in other clinical specimens. Research Institute for Gastroenterology and Liver Diseases 2011 /pmc/articles/PMC4017407/ /pubmed/24834163 Text en Copyright © 2011 Research Institute for Gastroenterology and Liver Diseases http://creativecommons.org/licenses/by-nc/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Nejad, Mohammad Rostami Roshani, Mohammad Lahmi, Farhad Mojarad, Ehsan Nazemalhosseini Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title | Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title_full | Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title_fullStr | Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title_full_unstemmed | Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title_short | Evaluation of four DNA extraction methods for the detection of Echinococcus granulosus genotype 1 |
title_sort | evaluation of four dna extraction methods for the detection of echinococcus granulosus genotype 1 |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4017407/ https://www.ncbi.nlm.nih.gov/pubmed/24834163 |
work_keys_str_mv | AT nejadmohammadrostami evaluationoffourdnaextractionmethodsforthedetectionofechinococcusgranulosusgenotype1 AT roshanimohammad evaluationoffourdnaextractionmethodsforthedetectionofechinococcusgranulosusgenotype1 AT lahmifarhad evaluationoffourdnaextractionmethodsforthedetectionofechinococcusgranulosusgenotype1 AT mojaradehsannazemalhosseini evaluationoffourdnaextractionmethodsforthedetectionofechinococcusgranulosusgenotype1 |