Cargando…

Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients

AIMS/INTRODUCTION: To realize the effectiveness of a novel system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET), outpatients undergoing oral glucose tolerance tests (OGTT) were investigated for the efficacy of screening for...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakamoto, Kenya, Kubo, Fumiyo, Yoshiuchi, Kazutomi, Ono, Akemi, Sato, Toshiyuki, Tomita, Koji, Sakaguchi, Kazuhiko, Matsuhisa, Munehide, Kaneto, Hideaki, Maegawa, Hiroshi, Nakajima, Hiromu, Kashiwagi, Atsunori, Kosugi, Keisuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley-Blackwell 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4020250/
https://www.ncbi.nlm.nih.gov/pubmed/24843709
http://dx.doi.org/10.1111/jdi.12096
_version_ 1782316037573705728
author Sakamoto, Kenya
Kubo, Fumiyo
Yoshiuchi, Kazutomi
Ono, Akemi
Sato, Toshiyuki
Tomita, Koji
Sakaguchi, Kazuhiko
Matsuhisa, Munehide
Kaneto, Hideaki
Maegawa, Hiroshi
Nakajima, Hiromu
Kashiwagi, Atsunori
Kosugi, Keisuke
author_facet Sakamoto, Kenya
Kubo, Fumiyo
Yoshiuchi, Kazutomi
Ono, Akemi
Sato, Toshiyuki
Tomita, Koji
Sakaguchi, Kazuhiko
Matsuhisa, Munehide
Kaneto, Hideaki
Maegawa, Hiroshi
Nakajima, Hiromu
Kashiwagi, Atsunori
Kosugi, Keisuke
author_sort Sakamoto, Kenya
collection PubMed
description AIMS/INTRODUCTION: To realize the effectiveness of a novel system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET), outpatients undergoing oral glucose tolerance tests (OGTT) were investigated for the efficacy of screening for glucose intolerance using this system. MATERIALS AND METHODS: Fifty outpatients scheduled to undergo a 75‐g OGTT for medical reasons were recruited to the study. An area of skin on the forearm was pretreated with microneedle arrays before the application of hydrogels for interstitial fluid extraction. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference (actual) AUC. The AUC was predicted by MIET on the basis of glucose extracted by the hydrogel using sodium ion levels as the internal standard. RESULTS: Good correlation between MIET‐predicted and reference AUCs obtained using PG levels was confirmed for a wide AUC range. By introducing a threshold level for AUC to separate glucose intolerance with peak glucose ≥180 mg/dL from normal glucose tolerance, the system was demonstrated to provide better screening accuracy compared with conventional methods that use HbA1c and fasting PG levels. The results of a questionnaire‐based survey administered to the subjects suggested that this system was readily accepted by the majority as a painless monitoring method. CONCLUSIONS: The findings suggest that our glucose AUC measurement system using MIET would be useful for screening of glucose intolerance. In the future, this system may prove to be a useful aid as a screen for glucose intolerance before performing an OGTT for diagnosis.
format Online
Article
Text
id pubmed-4020250
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Wiley-Blackwell
record_format MEDLINE/PubMed
spelling pubmed-40202502014-05-19 Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients Sakamoto, Kenya Kubo, Fumiyo Yoshiuchi, Kazutomi Ono, Akemi Sato, Toshiyuki Tomita, Koji Sakaguchi, Kazuhiko Matsuhisa, Munehide Kaneto, Hideaki Maegawa, Hiroshi Nakajima, Hiromu Kashiwagi, Atsunori Kosugi, Keisuke J Diabetes Investig Articles AIMS/INTRODUCTION: To realize the effectiveness of a novel system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET), outpatients undergoing oral glucose tolerance tests (OGTT) were investigated for the efficacy of screening for glucose intolerance using this system. MATERIALS AND METHODS: Fifty outpatients scheduled to undergo a 75‐g OGTT for medical reasons were recruited to the study. An area of skin on the forearm was pretreated with microneedle arrays before the application of hydrogels for interstitial fluid extraction. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference (actual) AUC. The AUC was predicted by MIET on the basis of glucose extracted by the hydrogel using sodium ion levels as the internal standard. RESULTS: Good correlation between MIET‐predicted and reference AUCs obtained using PG levels was confirmed for a wide AUC range. By introducing a threshold level for AUC to separate glucose intolerance with peak glucose ≥180 mg/dL from normal glucose tolerance, the system was demonstrated to provide better screening accuracy compared with conventional methods that use HbA1c and fasting PG levels. The results of a questionnaire‐based survey administered to the subjects suggested that this system was readily accepted by the majority as a painless monitoring method. CONCLUSIONS: The findings suggest that our glucose AUC measurement system using MIET would be useful for screening of glucose intolerance. In the future, this system may prove to be a useful aid as a screen for glucose intolerance before performing an OGTT for diagnosis. Wiley-Blackwell 2013-05-08 2013-11-27 /pmc/articles/PMC4020250/ /pubmed/24843709 http://dx.doi.org/10.1111/jdi.12096 Text en Copyright © 2013 Asian Association for the Study of Diabetes and Wiley Publishing Asia Pty Ltd
spellingShingle Articles
Sakamoto, Kenya
Kubo, Fumiyo
Yoshiuchi, Kazutomi
Ono, Akemi
Sato, Toshiyuki
Tomita, Koji
Sakaguchi, Kazuhiko
Matsuhisa, Munehide
Kaneto, Hideaki
Maegawa, Hiroshi
Nakajima, Hiromu
Kashiwagi, Atsunori
Kosugi, Keisuke
Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title_full Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title_fullStr Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title_full_unstemmed Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title_short Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
title_sort usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4020250/
https://www.ncbi.nlm.nih.gov/pubmed/24843709
http://dx.doi.org/10.1111/jdi.12096
work_keys_str_mv AT sakamotokenya usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT kubofumiyo usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT yoshiuchikazutomi usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT onoakemi usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT satotoshiyuki usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT tomitakoji usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT sakaguchikazuhiko usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT matsuhisamunehide usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT kanetohideaki usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT maegawahiroshi usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT nakajimahiromu usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT kashiwagiatsunori usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients
AT kosugikeisuke usefulnessofanovelsystemformeasuringglucoseareaunderthecurvewhilescreeningforglucoseintoleranceinoutpatients