Cargando…

Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels

Silica coated silver (Ag@SiO(2)) nanoparticles were prepared and characterized by transmission electron microscope (TEM) and UV-vis absorption, and the nanoparticles were used as labels in sandwich-type immunosensor of Escherichia coli O157:H7 (E. coli O157:H7). The labels involved in immunoreaction...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Guang-Zhu, Yin, Zheng-Zhi, Lou, Jv-Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4020444/
https://www.ncbi.nlm.nih.gov/pubmed/24872904
http://dx.doi.org/10.1155/2014/247034
_version_ 1782316066090778624
author Chen, Guang-Zhu
Yin, Zheng-Zhi
Lou, Jv-Feng
author_facet Chen, Guang-Zhu
Yin, Zheng-Zhi
Lou, Jv-Feng
author_sort Chen, Guang-Zhu
collection PubMed
description Silica coated silver (Ag@SiO(2)) nanoparticles were prepared and characterized by transmission electron microscope (TEM) and UV-vis absorption, and the nanoparticles were used as labels in sandwich-type immunosensor of Escherichia coli O157:H7 (E. coli O157:H7). The labels involved in immunoreaction were dissolved by mixed acid of hydrofluoric acid and nitric acid, and the released Ag(+) ions were electrochemical stripping analyzed (via differential pulse voltammetry, DPV) at poly(acrylic acid)/poly(diallyldimethylammonium chloride)/carbon nanotubes (PAA/PDCNT) modified glass carbon electrode (GCE), which obviously enhanced the signal of Ag(+) stripping. Then, the number of E. coli O157:H7 could be indirectly reflected by the signal intensity of labeled Ag(+). And the results showed that the DPV signals were proportional to the logarithm of the E. coli O157:H7 concentration in the range from 20 cfu/mL to 8.0 × 10(3) cfu/mL with the detection limit of 13 cfu/mL.
format Online
Article
Text
id pubmed-4020444
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40204442014-05-28 Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels Chen, Guang-Zhu Yin, Zheng-Zhi Lou, Jv-Feng J Anal Methods Chem Research Article Silica coated silver (Ag@SiO(2)) nanoparticles were prepared and characterized by transmission electron microscope (TEM) and UV-vis absorption, and the nanoparticles were used as labels in sandwich-type immunosensor of Escherichia coli O157:H7 (E. coli O157:H7). The labels involved in immunoreaction were dissolved by mixed acid of hydrofluoric acid and nitric acid, and the released Ag(+) ions were electrochemical stripping analyzed (via differential pulse voltammetry, DPV) at poly(acrylic acid)/poly(diallyldimethylammonium chloride)/carbon nanotubes (PAA/PDCNT) modified glass carbon electrode (GCE), which obviously enhanced the signal of Ag(+) stripping. Then, the number of E. coli O157:H7 could be indirectly reflected by the signal intensity of labeled Ag(+). And the results showed that the DPV signals were proportional to the logarithm of the E. coli O157:H7 concentration in the range from 20 cfu/mL to 8.0 × 10(3) cfu/mL with the detection limit of 13 cfu/mL. Hindawi Publishing Corporation 2014 2014-04-27 /pmc/articles/PMC4020444/ /pubmed/24872904 http://dx.doi.org/10.1155/2014/247034 Text en Copyright © 2014 Guang-Zhu Chen et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chen, Guang-Zhu
Yin, Zheng-Zhi
Lou, Jv-Feng
Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title_full Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title_fullStr Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title_full_unstemmed Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title_short Electrochemical Immunoassay of Escherichia coli O157:H7 Using Ag@SiO(2) Nanoparticles as Labels
title_sort electrochemical immunoassay of escherichia coli o157:h7 using ag@sio(2) nanoparticles as labels
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4020444/
https://www.ncbi.nlm.nih.gov/pubmed/24872904
http://dx.doi.org/10.1155/2014/247034
work_keys_str_mv AT chenguangzhu electrochemicalimmunoassayofescherichiacolio157h7usingagsio2nanoparticlesaslabels
AT yinzhengzhi electrochemicalimmunoassayofescherichiacolio157h7usingagsio2nanoparticlesaslabels
AT loujvfeng electrochemicalimmunoassayofescherichiacolio157h7usingagsio2nanoparticlesaslabels