Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
BACKGROUND: Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. FINDINGS: Twenty-one healthy individuals...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4021613/ https://www.ncbi.nlm.nih.gov/pubmed/24742001 http://dx.doi.org/10.1186/1743-0003-11-65 |
_version_ | 1782316267914395648 |
---|---|
author | Quek, June Brauer, Sandra G Treleaven, Julia Pua, Yong-Hao Mentiplay, Benjamin Clark, Ross Allan |
author_facet | Quek, June Brauer, Sandra G Treleaven, Julia Pua, Yong-Hao Mentiplay, Benjamin Clark, Ross Allan |
author_sort | Quek, June |
collection | PubMed |
description | BACKGROUND: Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. FINDINGS: Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1–7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant’s head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone. The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. CONCLUSION: The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine. |
format | Online Article Text |
id | pubmed-4021613 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-40216132014-05-16 Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion Quek, June Brauer, Sandra G Treleaven, Julia Pua, Yong-Hao Mentiplay, Benjamin Clark, Ross Allan J Neuroeng Rehabil Short Report BACKGROUND: Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. FINDINGS: Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1–7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant’s head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone. The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. CONCLUSION: The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine. BioMed Central 2014-04-17 /pmc/articles/PMC4021613/ /pubmed/24742001 http://dx.doi.org/10.1186/1743-0003-11-65 Text en Copyright © 2014 Quek et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Short Report Quek, June Brauer, Sandra G Treleaven, Julia Pua, Yong-Hao Mentiplay, Benjamin Clark, Ross Allan Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title | Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title_full | Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title_fullStr | Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title_full_unstemmed | Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title_short | Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion |
title_sort | validity and intra-rater reliability of an android phone application to measure cervical range-of-motion |
topic | Short Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4021613/ https://www.ncbi.nlm.nih.gov/pubmed/24742001 http://dx.doi.org/10.1186/1743-0003-11-65 |
work_keys_str_mv | AT quekjune validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion AT brauersandrag validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion AT treleavenjulia validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion AT puayonghao validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion AT mentiplaybenjamin validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion AT clarkrossallan validityandintraraterreliabilityofanandroidphoneapplicationtomeasurecervicalrangeofmotion |