Cargando…
Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters
With the objective of making advancements in the area of pro-thrombotic microparticle characterization in cardiovascular biology, we present a novel method to separate blood circulating microparticles using a membrane-based, nanopore filtration system. In this qualitative study, electron microscopy...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4021882/ https://www.ncbi.nlm.nih.gov/pubmed/24957960 http://dx.doi.org/10.3390/membranes2010001 |
_version_ | 1782316306731630592 |
---|---|
author | Peramo, Antonio Diaz, Jose A. |
author_facet | Peramo, Antonio Diaz, Jose A. |
author_sort | Peramo, Antonio |
collection | PubMed |
description | With the objective of making advancements in the area of pro-thrombotic microparticle characterization in cardiovascular biology, we present a novel method to separate blood circulating microparticles using a membrane-based, nanopore filtration system. In this qualitative study, electron microscopy observations of these pro-thrombotic mouse microparticles, as well as mouse platelets and leukocytes obtained using a mouse inferior vena cava ligation model of deep-vein thrombosis are presented. In particular, we present mouse microparticle morphology and microstructure using SEM and TEM indicating that they appear to be mostly spherical with diameters in the 100 to 350 nm range. The nanopore filtration technique presented is focused on the development of novel methodologies to isolate and characterize blood circulating microparticles that can be used in conjunction with other methodologies. We believe that determination of microparticle size and structure is a critical step for the development of reliable assays with clinical or research application in thrombosis and it will contribute to the field of nanomedicine in thrombosis. |
format | Online Article Text |
id | pubmed-4021882 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-40218822014-05-27 Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters Peramo, Antonio Diaz, Jose A. Membranes (Basel) Article With the objective of making advancements in the area of pro-thrombotic microparticle characterization in cardiovascular biology, we present a novel method to separate blood circulating microparticles using a membrane-based, nanopore filtration system. In this qualitative study, electron microscopy observations of these pro-thrombotic mouse microparticles, as well as mouse platelets and leukocytes obtained using a mouse inferior vena cava ligation model of deep-vein thrombosis are presented. In particular, we present mouse microparticle morphology and microstructure using SEM and TEM indicating that they appear to be mostly spherical with diameters in the 100 to 350 nm range. The nanopore filtration technique presented is focused on the development of novel methodologies to isolate and characterize blood circulating microparticles that can be used in conjunction with other methodologies. We believe that determination of microparticle size and structure is a critical step for the development of reliable assays with clinical or research application in thrombosis and it will contribute to the field of nanomedicine in thrombosis. MDPI 2011-12-27 /pmc/articles/PMC4021882/ /pubmed/24957960 http://dx.doi.org/10.3390/membranes2010001 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Peramo, Antonio Diaz, Jose A. Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title | Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title_full | Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title_fullStr | Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title_full_unstemmed | Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title_short | Physical Characterization of Mouse Deep Vein Thrombosis Derived Microparticles by Differential Filtration with Nanopore Filters |
title_sort | physical characterization of mouse deep vein thrombosis derived microparticles by differential filtration with nanopore filters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4021882/ https://www.ncbi.nlm.nih.gov/pubmed/24957960 http://dx.doi.org/10.3390/membranes2010001 |
work_keys_str_mv | AT peramoantonio physicalcharacterizationofmousedeepveinthrombosisderivedmicroparticlesbydifferentialfiltrationwithnanoporefilters AT diazjosea physicalcharacterizationofmousedeepveinthrombosisderivedmicroparticlesbydifferentialfiltrationwithnanoporefilters |