Cargando…
A new device for simple and accurate urinary pH testing by the Stone-former patient
PURPOSE: Urinary pH is an important factor linked to renal stone disease and a useful marker in the treatment of urolithiasis. Although the gold standard for measuring urinary pH utilizes a glass electrode and a pH meter, at present dipstick testing is largely used to estimate urinary pH. However, t...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4022968/ https://www.ncbi.nlm.nih.gov/pubmed/24839588 http://dx.doi.org/10.1186/2193-1801-3-209 |
_version_ | 1782316482260107264 |
---|---|
author | Grases, Felix Rodriguez, Adrian Berga, Francisco Costa-Bauza, Antonia Prieto, Rafael Maria Burdallo, Isabel Cadarso, Alfredo Jimenez-Jorquera, Cecilia Baldi, Antonio Garganta, Rosendo |
author_facet | Grases, Felix Rodriguez, Adrian Berga, Francisco Costa-Bauza, Antonia Prieto, Rafael Maria Burdallo, Isabel Cadarso, Alfredo Jimenez-Jorquera, Cecilia Baldi, Antonio Garganta, Rosendo |
author_sort | Grases, Felix |
collection | PubMed |
description | PURPOSE: Urinary pH is an important factor linked to renal stone disease and a useful marker in the treatment of urolithiasis. Although the gold standard for measuring urinary pH utilizes a glass electrode and a pH meter, at present dipstick testing is largely used to estimate urinary pH. However, the accuracy and precision of this method may be insufficient for making clinical decisions in patients with lithiasis. The aim of this study is to describe a new device for urinary pH testing. METHODS: The device includes a pH sensor based on differential measurement of an ISFET-REFET pair. The drawbacks associated with this type of configuration, namely short lifetime and manual fabrication, have been overcome in the prototype. An automatic one point calibration is performed when turning on the system. Two buffer solutions were utilized to determine the intra- and inter-day precision of the device. The pH of 30 fresh human urine samples was measured using a pH-meter, a dipstick and the new electronic device. RESULTS: In some cases, dipstick measurements differed from those of the pH meter by more than 0.40 units, a clinically relevant discrepancy, whereas none of the measurements made with the new electronic device differed from the results of the pH-meter by more than 0.1 pH units. CONCLUSIONS: This new electronic device has the possibility to be used by stone-formers to control their urinary pH at home, increasing the tools available for stone prevention and prophylaxis. |
format | Online Article Text |
id | pubmed-4022968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-40229682014-05-16 A new device for simple and accurate urinary pH testing by the Stone-former patient Grases, Felix Rodriguez, Adrian Berga, Francisco Costa-Bauza, Antonia Prieto, Rafael Maria Burdallo, Isabel Cadarso, Alfredo Jimenez-Jorquera, Cecilia Baldi, Antonio Garganta, Rosendo Springerplus Research PURPOSE: Urinary pH is an important factor linked to renal stone disease and a useful marker in the treatment of urolithiasis. Although the gold standard for measuring urinary pH utilizes a glass electrode and a pH meter, at present dipstick testing is largely used to estimate urinary pH. However, the accuracy and precision of this method may be insufficient for making clinical decisions in patients with lithiasis. The aim of this study is to describe a new device for urinary pH testing. METHODS: The device includes a pH sensor based on differential measurement of an ISFET-REFET pair. The drawbacks associated with this type of configuration, namely short lifetime and manual fabrication, have been overcome in the prototype. An automatic one point calibration is performed when turning on the system. Two buffer solutions were utilized to determine the intra- and inter-day precision of the device. The pH of 30 fresh human urine samples was measured using a pH-meter, a dipstick and the new electronic device. RESULTS: In some cases, dipstick measurements differed from those of the pH meter by more than 0.40 units, a clinically relevant discrepancy, whereas none of the measurements made with the new electronic device differed from the results of the pH-meter by more than 0.1 pH units. CONCLUSIONS: This new electronic device has the possibility to be used by stone-formers to control their urinary pH at home, increasing the tools available for stone prevention and prophylaxis. Springer International Publishing 2014-04-28 /pmc/articles/PMC4022968/ /pubmed/24839588 http://dx.doi.org/10.1186/2193-1801-3-209 Text en © Grases et al.; licensee Springer. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Research Grases, Felix Rodriguez, Adrian Berga, Francisco Costa-Bauza, Antonia Prieto, Rafael Maria Burdallo, Isabel Cadarso, Alfredo Jimenez-Jorquera, Cecilia Baldi, Antonio Garganta, Rosendo A new device for simple and accurate urinary pH testing by the Stone-former patient |
title | A new device for simple and accurate urinary pH testing by the Stone-former patient |
title_full | A new device for simple and accurate urinary pH testing by the Stone-former patient |
title_fullStr | A new device for simple and accurate urinary pH testing by the Stone-former patient |
title_full_unstemmed | A new device for simple and accurate urinary pH testing by the Stone-former patient |
title_short | A new device for simple and accurate urinary pH testing by the Stone-former patient |
title_sort | new device for simple and accurate urinary ph testing by the stone-former patient |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4022968/ https://www.ncbi.nlm.nih.gov/pubmed/24839588 http://dx.doi.org/10.1186/2193-1801-3-209 |
work_keys_str_mv | AT grasesfelix anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT rodriguezadrian anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT bergafrancisco anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT costabauzaantonia anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT prietorafaelmaria anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT burdalloisabel anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT cadarsoalfredo anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT jimenezjorqueracecilia anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT baldiantonio anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT gargantarosendo anewdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT grasesfelix newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT rodriguezadrian newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT bergafrancisco newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT costabauzaantonia newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT prietorafaelmaria newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT burdalloisabel newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT cadarsoalfredo newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT jimenezjorqueracecilia newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT baldiantonio newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient AT gargantarosendo newdeviceforsimpleandaccurateurinaryphtestingbythestoneformerpatient |