Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study
OBJECTIVE: The aim was to evaluate the intra- and inter-examiner reliability of two methods, namely, digital caliper [DC] and computerized image analysis software (Image Tool [IT] version 4.1) for measuring the area of an active enamel demineralization lesion. The effect on that measurement of a win...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4023199/ https://www.ncbi.nlm.nih.gov/pubmed/24883020 http://dx.doi.org/10.4103/1305-7456.110157 |
Sumario: | OBJECTIVE: The aim was to evaluate the intra- and inter-examiner reliability of two methods, namely, digital caliper [DC] and computerized image analysis software (Image Tool [IT] version 4.1) for measuring the area of an active enamel demineralization lesion. The effect on that measurement of a window that delimits the lesion was also assessed. MATERIALS AND METHODS: Thirty-eight circular artificial enamel demineralization lesions (r = 2 mm) were produced on bovine teeth in vitro, which were then measured three times by three examiners, with and without the presence of a window delimiting the area to be measured. The data were analyzed by the intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and by the Altman and Bland analysis. RESULTS: The intra-examiner correlation using the IT method showed excellent reproducibility (mean ICC values 0.922-0.970 with the delimiting window and 0.915-0.990 without the window). However, the intra-examiner correlation using the DC method showed comparatively less reproducibility in the measurements (mean ICC values 0.458-0.648 with the delimiting window and 0.378-0.665 without the window). The inter-examiner correlations showed very good reproducibility of the measurements regardless of the presence or absence of the window for both the DC method (0.811-0.846) and IT method (0.953-0.994). However, the latter method showed less variability within the measurements. CONCLUSION: However, statistically no significant difference was found between both methodologies. Nevertheless, computerized image analysis with the Image Tool software demonstrated higher intra- and inter-examiner reliability than the digital caliper method, in estimating the area of the enamel demineralization lesion, regardless of the delimiting window. |
---|