Cargando…
Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage
OBJECTIVE: The bond strength of adhesives in irrigated dentin behaves differently over time. The aim of this study was to evaluate the influence of long-term water storage and thermocycling on the microtensile bond strength of adhesive systems to dentin irrigated with endodontic solutions. MATERIALS...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4025426/ https://www.ncbi.nlm.nih.gov/pubmed/24910650 |
_version_ | 1782316757037350912 |
---|---|
author | Galafassi, Daniel Colucci, Vivian Cecchin, Doglas Scatena, Camila Nascimento, Telma N. Corona, Silmara A. M. |
author_facet | Galafassi, Daniel Colucci, Vivian Cecchin, Doglas Scatena, Camila Nascimento, Telma N. Corona, Silmara A. M. |
author_sort | Galafassi, Daniel |
collection | PubMed |
description | OBJECTIVE: The bond strength of adhesives in irrigated dentin behaves differently over time. The aim of this study was to evaluate the influence of long-term water storage and thermocycling on the microtensile bond strength of adhesive systems to dentin irrigated with endodontic solutions. MATERIALS AND METHODS: Sixty human molars were used after removal of the occlusal portion and exposure of the dentin by grinding. The specimens were irrigated with 2.5% NaOCl for 30 minutes and then 17% EDTA for 5 minutes and assigned to six groups according to the adhesive system (n=10): G1 and G2–Clearfil SE Bond; G3 and G4–Single Bond 2; and G5 and G6–XP Bond. The teeth were restored with composite and were subjected to water storage for different time periods. G1, G3 and G5 were stored for 24 h; G2, G4 and G6 were stored for 6 months and were subjected to thermocycling (12,000 cycles, 5°C to 55°C, 500 cycles per week for 6 months). After storage, the tooth/restoration assembly was sectioned to obtain four sticks of approximately 1 mm(2), for microtensile bond strength testing. The results were analyzed by two-way ANOVA and Tukey’s test. RESULTS: Significant differences were observed among the adhesives (p<0.01). No significant differences were observed in the microtensile bond strength between samples after 24 hours of storage without thermocycling and after 6-month storage with 12,000 cycles (p<0.05). CONCLUSION: The bond strengths of G5 and G6 after irrigation with 2.5% NaOCl and 17% EDTA were significantly different from those of other groups. Long-term water storage/thermocycling had no effect on bond strength to dentin. |
format | Online Article Text |
id | pubmed-4025426 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-40254262014-06-06 Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage Galafassi, Daniel Colucci, Vivian Cecchin, Doglas Scatena, Camila Nascimento, Telma N. Corona, Silmara A. M. J Dent (Tehran) Original Article OBJECTIVE: The bond strength of adhesives in irrigated dentin behaves differently over time. The aim of this study was to evaluate the influence of long-term water storage and thermocycling on the microtensile bond strength of adhesive systems to dentin irrigated with endodontic solutions. MATERIALS AND METHODS: Sixty human molars were used after removal of the occlusal portion and exposure of the dentin by grinding. The specimens were irrigated with 2.5% NaOCl for 30 minutes and then 17% EDTA for 5 minutes and assigned to six groups according to the adhesive system (n=10): G1 and G2–Clearfil SE Bond; G3 and G4–Single Bond 2; and G5 and G6–XP Bond. The teeth were restored with composite and were subjected to water storage for different time periods. G1, G3 and G5 were stored for 24 h; G2, G4 and G6 were stored for 6 months and were subjected to thermocycling (12,000 cycles, 5°C to 55°C, 500 cycles per week for 6 months). After storage, the tooth/restoration assembly was sectioned to obtain four sticks of approximately 1 mm(2), for microtensile bond strength testing. The results were analyzed by two-way ANOVA and Tukey’s test. RESULTS: Significant differences were observed among the adhesives (p<0.01). No significant differences were observed in the microtensile bond strength between samples after 24 hours of storage without thermocycling and after 6-month storage with 12,000 cycles (p<0.05). CONCLUSION: The bond strengths of G5 and G6 after irrigation with 2.5% NaOCl and 17% EDTA were significantly different from those of other groups. Long-term water storage/thermocycling had no effect on bond strength to dentin. Tehran University of Medical Sciences 2013-09 2013-09-30 /pmc/articles/PMC4025426/ /pubmed/24910650 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Galafassi, Daniel Colucci, Vivian Cecchin, Doglas Scatena, Camila Nascimento, Telma N. Corona, Silmara A. M. Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title | Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title_full | Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title_fullStr | Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title_full_unstemmed | Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title_short | Effect of Endodontic Irrigants on Microtensile Bond Strength to Dentin After Thermocycling and Long-Term Water Storage |
title_sort | effect of endodontic irrigants on microtensile bond strength to dentin after thermocycling and long-term water storage |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4025426/ https://www.ncbi.nlm.nih.gov/pubmed/24910650 |
work_keys_str_mv | AT galafassidaniel effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage AT coluccivivian effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage AT cecchindoglas effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage AT scatenacamila effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage AT nascimentotelman effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage AT coronasilmaraam effectofendodonticirrigantsonmicrotensilebondstrengthtodentinafterthermocyclingandlongtermwaterstorage |