Cargando…

Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures

BACKGROUND: Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-calibe...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuhn, Sebastian, Appelmann, Philipp, Mehler, Dorothea, Pairon, Philip, Rommens, Pol M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4026593/
https://www.ncbi.nlm.nih.gov/pubmed/24886667
http://dx.doi.org/10.1186/1749-799X-9-35
_version_ 1782316861044555776
author Kuhn, Sebastian
Appelmann, Philipp
Mehler, Dorothea
Pairon, Philip
Rommens, Pol M
author_facet Kuhn, Sebastian
Appelmann, Philipp
Mehler, Dorothea
Pairon, Philip
Rommens, Pol M
author_sort Kuhn, Sebastian
collection PubMed
description BACKGROUND: Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-caliber prototype implant, which is introduced through a 2-cm-long incision at the tip of the medial malleolus with stab incisions sufficient for interlocking. During this project, we investigated the feasibility of retrograde tibial nailing in a cadaver model and conducted biomechanical testing. METHODS: Anatomical implantations of the RTN were carried out in AO/OTA 43 A1-3 fracture types in three cadaveric lower limbs. Biomechanical testing was conducted in an AO/OTA 43 A3 fracture model for extra-axial compression, torsion, and destructive extra-axial compression. Sixteen composite tibiae were used to compare the RTN against an angle-stable plate osteosynthesis (Medial Distal Tibial Plate, Synthes(®)). Statistical analysis was performed by Student's t test. RESULTS: Retrograde intramedullary nailing is feasible in simple fracture types by closed manual reduction and percutaneous reduction forceps, while in highly comminuted fractures, the use of a large distractor can aid the reduction. Biomechanical testing shows a statistically superior stability (p < 0.001) of the RTN during non-destructive axial loading and torsion. Destructive extra-axial compression testing resulted in failure of all plate constructs, while all RTN specimens survived the maximal load of 1,200 N. CONCLUSIONS: The prototype retrograde tibial nail meets the requirements of maximum soft tissue protection by a minimally invasive surgical approach with the ability of secure fracture fixation by multiple locking options. Retrograde tibial nailing with the RTN is a promising concept in the treatment of distal tibia fractures.
format Online
Article
Text
id pubmed-4026593
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-40265932014-05-21 Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures Kuhn, Sebastian Appelmann, Philipp Mehler, Dorothea Pairon, Philip Rommens, Pol M J Orthop Surg Res Research Article BACKGROUND: Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-caliber prototype implant, which is introduced through a 2-cm-long incision at the tip of the medial malleolus with stab incisions sufficient for interlocking. During this project, we investigated the feasibility of retrograde tibial nailing in a cadaver model and conducted biomechanical testing. METHODS: Anatomical implantations of the RTN were carried out in AO/OTA 43 A1-3 fracture types in three cadaveric lower limbs. Biomechanical testing was conducted in an AO/OTA 43 A3 fracture model for extra-axial compression, torsion, and destructive extra-axial compression. Sixteen composite tibiae were used to compare the RTN against an angle-stable plate osteosynthesis (Medial Distal Tibial Plate, Synthes(®)). Statistical analysis was performed by Student's t test. RESULTS: Retrograde intramedullary nailing is feasible in simple fracture types by closed manual reduction and percutaneous reduction forceps, while in highly comminuted fractures, the use of a large distractor can aid the reduction. Biomechanical testing shows a statistically superior stability (p < 0.001) of the RTN during non-destructive axial loading and torsion. Destructive extra-axial compression testing resulted in failure of all plate constructs, while all RTN specimens survived the maximal load of 1,200 N. CONCLUSIONS: The prototype retrograde tibial nail meets the requirements of maximum soft tissue protection by a minimally invasive surgical approach with the ability of secure fracture fixation by multiple locking options. Retrograde tibial nailing with the RTN is a promising concept in the treatment of distal tibia fractures. BioMed Central 2014-05-13 /pmc/articles/PMC4026593/ /pubmed/24886667 http://dx.doi.org/10.1186/1749-799X-9-35 Text en Copyright © 2014 Kuhn et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kuhn, Sebastian
Appelmann, Philipp
Mehler, Dorothea
Pairon, Philip
Rommens, Pol M
Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title_full Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title_fullStr Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title_full_unstemmed Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title_short Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
title_sort retrograde tibial nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4026593/
https://www.ncbi.nlm.nih.gov/pubmed/24886667
http://dx.doi.org/10.1186/1749-799X-9-35
work_keys_str_mv AT kuhnsebastian retrogradetibialnailingaminimallyinvasiveandbiomechanicallysuperioralternativetoanglestableplateosteosynthesisindistaltibiafractures
AT appelmannphilipp retrogradetibialnailingaminimallyinvasiveandbiomechanicallysuperioralternativetoanglestableplateosteosynthesisindistaltibiafractures
AT mehlerdorothea retrogradetibialnailingaminimallyinvasiveandbiomechanicallysuperioralternativetoanglestableplateosteosynthesisindistaltibiafractures
AT paironphilip retrogradetibialnailingaminimallyinvasiveandbiomechanicallysuperioralternativetoanglestableplateosteosynthesisindistaltibiafractures
AT rommenspolm retrogradetibialnailingaminimallyinvasiveandbiomechanicallysuperioralternativetoanglestableplateosteosynthesisindistaltibiafractures