WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance

The Microlife(®) ‘WatchBP Home A’ oscillometric blood pressure monitor detects irregular pulse, suggestive of atrial fibrillation (AF). Early detection of AF can prevent thromboembolic stroke via anticoagulation therapy. The device was considered by the Medical Technologies Evaluation Programme of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Willits, Iain, Keltie, Kim, Craig, Joyce, Sims, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4026667/
https://www.ncbi.nlm.nih.gov/pubmed/24664995
http://dx.doi.org/10.1007/s40258-014-0096-7
_version_ 1782316877866860544
author Willits, Iain
Keltie, Kim
Craig, Joyce
Sims, Andrew
author_facet Willits, Iain
Keltie, Kim
Craig, Joyce
Sims, Andrew
author_sort Willits, Iain
collection PubMed
description The Microlife(®) ‘WatchBP Home A’ oscillometric blood pressure monitor detects irregular pulse, suggestive of atrial fibrillation (AF). Early detection of AF can prevent thromboembolic stroke via anticoagulation therapy. The device was considered by the Medical Technologies Evaluation Programme of the UK National Institute for Health and Care Excellence (NICE). The sponsor (Microlife) identified 10 studies. These were reviewed by an External Assessment Centre (EAC) which considered three relevant to the decision problem, including one which found the device detected AF more accurately (sensitivity 96.8 %, specificity 88.8 %) than pulse palpation (87.2, 81.3 %). The EAC concluded the technology had potential to improve detection of AF, but the three studies had uncertain external validity. From a cost-consequence model with a 1-year timeframe, the sponsor calculated the device would reduce electrocardiogram (ECG) referrals and prevent strokes, but incur anticoagulation therapy costs, with net NHS savings of £11.6 million and prevention of 221 strokes, annually. The EAC criticised the model for its limited time horizon, and its consideration of symptomatic AF patients who were outside the scope issued by NICE. The EAC applied a de novo Markov model, with a 10-year timeframe. The per use saving was calculated as £2.98 for asymptomatic patients aged 65–74 years and £4.26 for those aged 75–84 years, with the prevention of 53–117 nonfatal and 28–65 fatal strokes per 100,000 people screened. Following consideration by the NICE Medical Technologies Advisory Committee, NICE judged that the case for adoption was supported by the evidence (Medical Technologies Guidance 13; MTG13).
format Online
Article
Text
id pubmed-4026667
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-40266672014-05-22 WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance Willits, Iain Keltie, Kim Craig, Joyce Sims, Andrew Appl Health Econ Health Policy Review Article The Microlife(®) ‘WatchBP Home A’ oscillometric blood pressure monitor detects irregular pulse, suggestive of atrial fibrillation (AF). Early detection of AF can prevent thromboembolic stroke via anticoagulation therapy. The device was considered by the Medical Technologies Evaluation Programme of the UK National Institute for Health and Care Excellence (NICE). The sponsor (Microlife) identified 10 studies. These were reviewed by an External Assessment Centre (EAC) which considered three relevant to the decision problem, including one which found the device detected AF more accurately (sensitivity 96.8 %, specificity 88.8 %) than pulse palpation (87.2, 81.3 %). The EAC concluded the technology had potential to improve detection of AF, but the three studies had uncertain external validity. From a cost-consequence model with a 1-year timeframe, the sponsor calculated the device would reduce electrocardiogram (ECG) referrals and prevent strokes, but incur anticoagulation therapy costs, with net NHS savings of £11.6 million and prevention of 221 strokes, annually. The EAC criticised the model for its limited time horizon, and its consideration of symptomatic AF patients who were outside the scope issued by NICE. The EAC applied a de novo Markov model, with a 10-year timeframe. The per use saving was calculated as £2.98 for asymptomatic patients aged 65–74 years and £4.26 for those aged 75–84 years, with the prevention of 53–117 nonfatal and 28–65 fatal strokes per 100,000 people screened. Following consideration by the NICE Medical Technologies Advisory Committee, NICE judged that the case for adoption was supported by the evidence (Medical Technologies Guidance 13; MTG13). Springer International Publishing 2014-03-25 2014 /pmc/articles/PMC4026667/ /pubmed/24664995 http://dx.doi.org/10.1007/s40258-014-0096-7 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by-nc/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Review Article
Willits, Iain
Keltie, Kim
Craig, Joyce
Sims, Andrew
WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title_full WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title_fullStr WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title_full_unstemmed WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title_short WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance
title_sort watchbp home a for opportunistically detecting atrial fibrillation during diagnosis and monitoring of hypertension: a nice medical technology guidance
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4026667/
https://www.ncbi.nlm.nih.gov/pubmed/24664995
http://dx.doi.org/10.1007/s40258-014-0096-7
work_keys_str_mv AT willitsiain watchbphomeaforopportunisticallydetectingatrialfibrillationduringdiagnosisandmonitoringofhypertensionanicemedicaltechnologyguidance
AT keltiekim watchbphomeaforopportunisticallydetectingatrialfibrillationduringdiagnosisandmonitoringofhypertensionanicemedicaltechnologyguidance
AT craigjoyce watchbphomeaforopportunisticallydetectingatrialfibrillationduringdiagnosisandmonitoringofhypertensionanicemedicaltechnologyguidance
AT simsandrew watchbphomeaforopportunisticallydetectingatrialfibrillationduringdiagnosisandmonitoringofhypertensionanicemedicaltechnologyguidance