Cargando…
Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial
BACKGROUND: To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. OBJECTIVES: The aim of this relatively large randomized trial was to compare the hemodynamic stress responses dur...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4028761/ https://www.ncbi.nlm.nih.gov/pubmed/24910788 http://dx.doi.org/10.5812/ircmj.12334 |
_version_ | 1782317099139465216 |
---|---|
author | Pournajafian, Ali Reza Ghodraty, Mohammad Reza Faiz, Seyed Hamid Reza Rahimzadeh, Poupak Goodarzynejad, Hamidreza Dogmehchi, Enseyeh |
author_facet | Pournajafian, Ali Reza Ghodraty, Mohammad Reza Faiz, Seyed Hamid Reza Rahimzadeh, Poupak Goodarzynejad, Hamidreza Dogmehchi, Enseyeh |
author_sort | Pournajafian, Ali Reza |
collection | PubMed |
description | BACKGROUND: To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. OBJECTIVES: The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries. PATIENTS AND METHODS: Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms. All patients received a standardized protocol of general anesthesia. Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation. The time taken to perform endotracheal intubation was also noted in both groups. RESULTS: Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05). Blood pressures and HR values changed significantly over time within the groups. Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P< 0.001). However, there were no significant differences between the two groups in hemodynamic responses at all time points. CONCLUSIONS: The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group. |
format | Online Article Text |
id | pubmed-4028761 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-40287612014-06-06 Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial Pournajafian, Ali Reza Ghodraty, Mohammad Reza Faiz, Seyed Hamid Reza Rahimzadeh, Poupak Goodarzynejad, Hamidreza Dogmehchi, Enseyeh Iran Red Crescent Med J Research Article BACKGROUND: To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. OBJECTIVES: The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries. PATIENTS AND METHODS: Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms. All patients received a standardized protocol of general anesthesia. Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation. The time taken to perform endotracheal intubation was also noted in both groups. RESULTS: Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05). Blood pressures and HR values changed significantly over time within the groups. Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P< 0.001). However, there were no significant differences between the two groups in hemodynamic responses at all time points. CONCLUSIONS: The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group. Kowsar 2014-04-05 2014-04 /pmc/articles/PMC4028761/ /pubmed/24910788 http://dx.doi.org/10.5812/ircmj.12334 Text en Copyright © 2014, Iranian Red Crescent Medical Journal; Published by Kowsar Corp. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Pournajafian, Ali Reza Ghodraty, Mohammad Reza Faiz, Seyed Hamid Reza Rahimzadeh, Poupak Goodarzynejad, Hamidreza Dogmehchi, Enseyeh Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title | Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title_full | Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title_fullStr | Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title_full_unstemmed | Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title_short | Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial |
title_sort | comparing glidescope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation: a randomized controlled trial |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4028761/ https://www.ncbi.nlm.nih.gov/pubmed/24910788 http://dx.doi.org/10.5812/ircmj.12334 |
work_keys_str_mv | AT pournajafianalireza comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial AT ghodratymohammadreza comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial AT faizseyedhamidreza comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial AT rahimzadehpoupak comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial AT goodarzynejadhamidreza comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial AT dogmehchienseyeh comparingglidescopevideolaryngoscopeandmacintoshlaryngoscoperegardinghemodynamicresponsesduringorotrachealintubationarandomizedcontrolledtrial |