Cargando…

Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions

BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as...

Descripción completa

Detalles Bibliográficos
Autores principales: Hagau, Natalia, Gherman-Ionica, Nadia, Sfichi, Manuela, Petrisor, Cristina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029498/
https://www.ncbi.nlm.nih.gov/pubmed/24499278
http://dx.doi.org/10.1186/1710-1492-9-42
_version_ 1782317219566321664
author Hagau, Natalia
Gherman-Ionica, Nadia
Sfichi, Manuela
Petrisor, Cristina
author_facet Hagau, Natalia
Gherman-Ionica, Nadia
Sfichi, Manuela
Petrisor, Cristina
author_sort Hagau, Natalia
collection PubMed
description BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as the stimulation index (SI, calculated as the percentage of activated basophils after stimulation with NMBA divided by the number of basophils with no NMBA stimulation) and as the percentage of activated basophils, and to determine the sensitivity and specificity of BAT for NMBAs. METHODS: 22 consenting adult patients with previous intraanaesthetic NMBAs-related hypersensitivity reactions were tested for the culprit drug. 34 controls who tolerated NMBAs were similarly tested. BAT was performed using Flow2Cast technique and the up-regulation of the CD63 marker on the basophils was measured using Cell Quest programme (FACSCalibur Becton Dickinson, USA). Receiver operating characteristics curve (ROC) analysis was performed. RESULTS: ROC curve analysis for BAT results versus history yields a stimulation index of 1.76 as the optimal threshold, with an AUC of 0.81 (CI 95% 0.69-0.93, p < 0.01) and a percentage of activated basophils > 5.01%, with an AUC of 0.84 (CI 95% 0.72-0.95, p < 0.01). Considering both thresholds (the SI ≥ 1.76 together with the percentage of activated basophils > 5%) as diagnostic criteria, 15 patients had positive BAT, the overall BAT sensitivity being 68.18% (CI 95% 45.11-82.26%). None of the controls fulfilled both criteria and the specificity of the test was 100% (CI 95% 87.35-100%). CONCLUSIONS: With a stimulation index ≥ 1.76 and a percentage of activated basophils > 5.01% as threshold, the performance of BAT for NMBAs yields 68.18% sensitivity and 100% specificity.
format Online
Article
Text
id pubmed-4029498
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-40294982014-05-22 Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions Hagau, Natalia Gherman-Ionica, Nadia Sfichi, Manuela Petrisor, Cristina Allergy Asthma Clin Immunol Research BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as the stimulation index (SI, calculated as the percentage of activated basophils after stimulation with NMBA divided by the number of basophils with no NMBA stimulation) and as the percentage of activated basophils, and to determine the sensitivity and specificity of BAT for NMBAs. METHODS: 22 consenting adult patients with previous intraanaesthetic NMBAs-related hypersensitivity reactions were tested for the culprit drug. 34 controls who tolerated NMBAs were similarly tested. BAT was performed using Flow2Cast technique and the up-regulation of the CD63 marker on the basophils was measured using Cell Quest programme (FACSCalibur Becton Dickinson, USA). Receiver operating characteristics curve (ROC) analysis was performed. RESULTS: ROC curve analysis for BAT results versus history yields a stimulation index of 1.76 as the optimal threshold, with an AUC of 0.81 (CI 95% 0.69-0.93, p < 0.01) and a percentage of activated basophils > 5.01%, with an AUC of 0.84 (CI 95% 0.72-0.95, p < 0.01). Considering both thresholds (the SI ≥ 1.76 together with the percentage of activated basophils > 5%) as diagnostic criteria, 15 patients had positive BAT, the overall BAT sensitivity being 68.18% (CI 95% 45.11-82.26%). None of the controls fulfilled both criteria and the specificity of the test was 100% (CI 95% 87.35-100%). CONCLUSIONS: With a stimulation index ≥ 1.76 and a percentage of activated basophils > 5.01% as threshold, the performance of BAT for NMBAs yields 68.18% sensitivity and 100% specificity. BioMed Central 2013-10-23 /pmc/articles/PMC4029498/ /pubmed/24499278 http://dx.doi.org/10.1186/1710-1492-9-42 Text en Copyright © 2013 Hagau et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Hagau, Natalia
Gherman-Ionica, Nadia
Sfichi, Manuela
Petrisor, Cristina
Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title_full Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title_fullStr Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title_full_unstemmed Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title_short Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
title_sort threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029498/
https://www.ncbi.nlm.nih.gov/pubmed/24499278
http://dx.doi.org/10.1186/1710-1492-9-42
work_keys_str_mv AT hagaunatalia thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions
AT ghermanionicanadia thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions
AT sfichimanuela thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions
AT petrisorcristina thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions