Cargando…
Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions
BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029498/ https://www.ncbi.nlm.nih.gov/pubmed/24499278 http://dx.doi.org/10.1186/1710-1492-9-42 |
_version_ | 1782317219566321664 |
---|---|
author | Hagau, Natalia Gherman-Ionica, Nadia Sfichi, Manuela Petrisor, Cristina |
author_facet | Hagau, Natalia Gherman-Ionica, Nadia Sfichi, Manuela Petrisor, Cristina |
author_sort | Hagau, Natalia |
collection | PubMed |
description | BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as the stimulation index (SI, calculated as the percentage of activated basophils after stimulation with NMBA divided by the number of basophils with no NMBA stimulation) and as the percentage of activated basophils, and to determine the sensitivity and specificity of BAT for NMBAs. METHODS: 22 consenting adult patients with previous intraanaesthetic NMBAs-related hypersensitivity reactions were tested for the culprit drug. 34 controls who tolerated NMBAs were similarly tested. BAT was performed using Flow2Cast technique and the up-regulation of the CD63 marker on the basophils was measured using Cell Quest programme (FACSCalibur Becton Dickinson, USA). Receiver operating characteristics curve (ROC) analysis was performed. RESULTS: ROC curve analysis for BAT results versus history yields a stimulation index of 1.76 as the optimal threshold, with an AUC of 0.81 (CI 95% 0.69-0.93, p < 0.01) and a percentage of activated basophils > 5.01%, with an AUC of 0.84 (CI 95% 0.72-0.95, p < 0.01). Considering both thresholds (the SI ≥ 1.76 together with the percentage of activated basophils > 5%) as diagnostic criteria, 15 patients had positive BAT, the overall BAT sensitivity being 68.18% (CI 95% 45.11-82.26%). None of the controls fulfilled both criteria and the specificity of the test was 100% (CI 95% 87.35-100%). CONCLUSIONS: With a stimulation index ≥ 1.76 and a percentage of activated basophils > 5.01% as threshold, the performance of BAT for NMBAs yields 68.18% sensitivity and 100% specificity. |
format | Online Article Text |
id | pubmed-4029498 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-40294982014-05-22 Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions Hagau, Natalia Gherman-Ionica, Nadia Sfichi, Manuela Petrisor, Cristina Allergy Asthma Clin Immunol Research BACKGROUND: Several different criteria for the positivity of the flow-assisted Basophil Activation Test (BAT) for the diagnosis of Neuromuscular Blocking Agents (NMBA) hypersensitivity reactions have been used in past studies. Our aims were to determine the threshold for BAT positivity expressed as the stimulation index (SI, calculated as the percentage of activated basophils after stimulation with NMBA divided by the number of basophils with no NMBA stimulation) and as the percentage of activated basophils, and to determine the sensitivity and specificity of BAT for NMBAs. METHODS: 22 consenting adult patients with previous intraanaesthetic NMBAs-related hypersensitivity reactions were tested for the culprit drug. 34 controls who tolerated NMBAs were similarly tested. BAT was performed using Flow2Cast technique and the up-regulation of the CD63 marker on the basophils was measured using Cell Quest programme (FACSCalibur Becton Dickinson, USA). Receiver operating characteristics curve (ROC) analysis was performed. RESULTS: ROC curve analysis for BAT results versus history yields a stimulation index of 1.76 as the optimal threshold, with an AUC of 0.81 (CI 95% 0.69-0.93, p < 0.01) and a percentage of activated basophils > 5.01%, with an AUC of 0.84 (CI 95% 0.72-0.95, p < 0.01). Considering both thresholds (the SI ≥ 1.76 together with the percentage of activated basophils > 5%) as diagnostic criteria, 15 patients had positive BAT, the overall BAT sensitivity being 68.18% (CI 95% 45.11-82.26%). None of the controls fulfilled both criteria and the specificity of the test was 100% (CI 95% 87.35-100%). CONCLUSIONS: With a stimulation index ≥ 1.76 and a percentage of activated basophils > 5.01% as threshold, the performance of BAT for NMBAs yields 68.18% sensitivity and 100% specificity. BioMed Central 2013-10-23 /pmc/articles/PMC4029498/ /pubmed/24499278 http://dx.doi.org/10.1186/1710-1492-9-42 Text en Copyright © 2013 Hagau et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Hagau, Natalia Gherman-Ionica, Nadia Sfichi, Manuela Petrisor, Cristina Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title | Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title_full | Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title_fullStr | Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title_full_unstemmed | Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title_short | Threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
title_sort | threshold for basophil activation test positivity in neuromuscular blocking agents hypersensitivity reactions |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029498/ https://www.ncbi.nlm.nih.gov/pubmed/24499278 http://dx.doi.org/10.1186/1710-1492-9-42 |
work_keys_str_mv | AT hagaunatalia thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions AT ghermanionicanadia thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions AT sfichimanuela thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions AT petrisorcristina thresholdforbasophilactivationtestpositivityinneuromuscularblockingagentshypersensitivityreactions |