Cargando…

Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood

In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors...

Descripción completa

Detalles Bibliográficos
Autor principal: Jędrzejewska-Szczerska, Małgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029721/
https://www.ncbi.nlm.nih.gov/pubmed/24755518
http://dx.doi.org/10.3390/s140406965
_version_ 1782317265471930368
author Jędrzejewska-Szczerska, Małgorzata
author_facet Jędrzejewska-Szczerska, Małgorzata
author_sort Jędrzejewska-Szczerska, Małgorzata
collection PubMed
description In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing interferometer. The first step in the research on such sensor is the assessment of its performance under favorable conditions, i.e., using blood samples from healthy volunteers tested in vitro. Such an experiment was conducted using a sensor comprising a superluminescent diode source, an optical spectrum analyzer working as the detection setup and a sensing Fabry-Perot interferometer providing high interference contrast. The response of this sensor was recorded for several samples and compared with the reference laboratory method. The coefficient of determination (R(2)) for a linear relationship between the results given by both methods was 0.978 and the difference between these results was less than 1%. The presented results suggest that further research into the performance of the sensor is merited.
format Online
Article
Text
id pubmed-4029721
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-40297212014-05-22 Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood Jędrzejewska-Szczerska, Małgorzata Sensors (Basel) Article In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing interferometer. The first step in the research on such sensor is the assessment of its performance under favorable conditions, i.e., using blood samples from healthy volunteers tested in vitro. Such an experiment was conducted using a sensor comprising a superluminescent diode source, an optical spectrum analyzer working as the detection setup and a sensing Fabry-Perot interferometer providing high interference contrast. The response of this sensor was recorded for several samples and compared with the reference laboratory method. The coefficient of determination (R(2)) for a linear relationship between the results given by both methods was 0.978 and the difference between these results was less than 1%. The presented results suggest that further research into the performance of the sensor is merited. MDPI 2014-04-21 /pmc/articles/PMC4029721/ /pubmed/24755518 http://dx.doi.org/10.3390/s140406965 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Jędrzejewska-Szczerska, Małgorzata
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title_full Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title_fullStr Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title_full_unstemmed Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title_short Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
title_sort response of a new low-coherence fabry-perot sensor to hematocrit levels in human blood
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029721/
https://www.ncbi.nlm.nih.gov/pubmed/24755518
http://dx.doi.org/10.3390/s140406965
work_keys_str_mv AT jedrzejewskaszczerskamałgorzata responseofanewlowcoherencefabryperotsensortohematocritlevelsinhumanblood