Human Internal Jugular Valve M-mode Ultrasound Characterization

In humans the mechanism governing the internal jugular vein (IJV) valve opening and closure is still unclear. M-mode is used in echo-cardiology for the heart valves assessment. Sometimes it was performed also in deep peripheral veins and in vena cava assessment, but never in the IJV valve. Aim of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Menegatti, Erica, Tessari, Mirko, Gianesini, Sergio, Vannini, Maria Elena, Sisini, Francesco, Zamboni, Paolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Science Publishers 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4031920/
https://www.ncbi.nlm.nih.gov/pubmed/24712644
http://dx.doi.org/10.2174/1567202611666140408094014
_version_ 1782317585541365760
author Menegatti, Erica
Tessari, Mirko
Gianesini, Sergio
Vannini, Maria Elena
Sisini, Francesco
Zamboni, Paolo
author_facet Menegatti, Erica
Tessari, Mirko
Gianesini, Sergio
Vannini, Maria Elena
Sisini, Francesco
Zamboni, Paolo
author_sort Menegatti, Erica
collection PubMed
description In humans the mechanism governing the internal jugular vein (IJV) valve opening and closure is still unclear. M-mode is used in echo-cardiology for the heart valves assessment. Sometimes it was performed also in deep peripheral veins and in vena cava assessment, but never in the IJV valve. Aim of the present study is to investigate the IJV valves physiology in healthy volunteers, by means of both B and M-mode ultrasound. Eighty-three (83) healthy volunteers (35 Male, 48 Female, 25.7±6.7 y.o.), for a total of 166 IJVs, were enrolled. The entire cohort underwent IJVs high-resolution B and M-mode evaluation, in standardized postural and respiratory conditions. Presence, motility, and number of cusps, as well as their opening and closure mechanism have been assessed. Bilateral valve absence occurred in 13/83 (16%), whereas at least a one side absence was recorded in 38/83 (46‰ of the cohort) (p<0.0356). Valve leaflets were always mobile and respectively bi-cusps in 34%, or mono-cusp in 27%. The latter was significantly more frequent on the left side (35%) than on the right side (19%) (p<0.0013). In supine, M-mode valve opening was synchronous with the cardiac cycle. To the contrary, in an upright position, the valve remained always open and saddled to the wall, independently from the cardiac cycle. In healthy subjects, the IJV valve leaflets are always mobile, but the significant rate of mono and bilateral absence could suggest a progressive phylogenetic importance loss of such apparatus. M-mode ultrasound enhances the characterization of IJV valve, for this reason it should be taken into consideration to routinely add it to the cerebral venous return investigation.
format Online
Article
Text
id pubmed-4031920
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Bentham Science Publishers
record_format MEDLINE/PubMed
spelling pubmed-40319202014-05-27 Human Internal Jugular Valve M-mode Ultrasound Characterization Menegatti, Erica Tessari, Mirko Gianesini, Sergio Vannini, Maria Elena Sisini, Francesco Zamboni, Paolo Curr Neurovasc Res Article In humans the mechanism governing the internal jugular vein (IJV) valve opening and closure is still unclear. M-mode is used in echo-cardiology for the heart valves assessment. Sometimes it was performed also in deep peripheral veins and in vena cava assessment, but never in the IJV valve. Aim of the present study is to investigate the IJV valves physiology in healthy volunteers, by means of both B and M-mode ultrasound. Eighty-three (83) healthy volunteers (35 Male, 48 Female, 25.7±6.7 y.o.), for a total of 166 IJVs, were enrolled. The entire cohort underwent IJVs high-resolution B and M-mode evaluation, in standardized postural and respiratory conditions. Presence, motility, and number of cusps, as well as their opening and closure mechanism have been assessed. Bilateral valve absence occurred in 13/83 (16%), whereas at least a one side absence was recorded in 38/83 (46‰ of the cohort) (p<0.0356). Valve leaflets were always mobile and respectively bi-cusps in 34%, or mono-cusp in 27%. The latter was significantly more frequent on the left side (35%) than on the right side (19%) (p<0.0013). In supine, M-mode valve opening was synchronous with the cardiac cycle. To the contrary, in an upright position, the valve remained always open and saddled to the wall, independently from the cardiac cycle. In healthy subjects, the IJV valve leaflets are always mobile, but the significant rate of mono and bilateral absence could suggest a progressive phylogenetic importance loss of such apparatus. M-mode ultrasound enhances the characterization of IJV valve, for this reason it should be taken into consideration to routinely add it to the cerebral venous return investigation. Bentham Science Publishers 2013-05 2013-05 /pmc/articles/PMC4031920/ /pubmed/24712644 http://dx.doi.org/10.2174/1567202611666140408094014 Text en © Bentham Science Publishers http://creativecommons.org/licenses/by/2.5/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestrictive use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Menegatti, Erica
Tessari, Mirko
Gianesini, Sergio
Vannini, Maria Elena
Sisini, Francesco
Zamboni, Paolo
Human Internal Jugular Valve M-mode Ultrasound Characterization
title Human Internal Jugular Valve M-mode Ultrasound Characterization
title_full Human Internal Jugular Valve M-mode Ultrasound Characterization
title_fullStr Human Internal Jugular Valve M-mode Ultrasound Characterization
title_full_unstemmed Human Internal Jugular Valve M-mode Ultrasound Characterization
title_short Human Internal Jugular Valve M-mode Ultrasound Characterization
title_sort human internal jugular valve m-mode ultrasound characterization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4031920/
https://www.ncbi.nlm.nih.gov/pubmed/24712644
http://dx.doi.org/10.2174/1567202611666140408094014
work_keys_str_mv AT menegattierica humaninternaljugularvalvemmodeultrasoundcharacterization
AT tessarimirko humaninternaljugularvalvemmodeultrasoundcharacterization
AT gianesinisergio humaninternaljugularvalvemmodeultrasoundcharacterization
AT vanninimariaelena humaninternaljugularvalvemmodeultrasoundcharacterization
AT sisinifrancesco humaninternaljugularvalvemmodeultrasoundcharacterization
AT zambonipaolo humaninternaljugularvalvemmodeultrasoundcharacterization