Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy
BACKGROUND: Cardiac resynchronization therapy (CRT) has become an important pillar of contemporary heart failure therapy. The efficacy of CRT, however, critically relies on proper LV lead placement and performance, which is why data regarding the long-term performance of CS leads are of considerable...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Heart Rhythm Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4032778/ https://www.ncbi.nlm.nih.gov/pubmed/24948850 |
_version_ | 1782317701234950144 |
---|---|
author | Steffel, Jan Hurlimann, Anja Starck, Christoph Krasniqi, Nazmi Schmidt, Susann Luscher, Thomas F Duru, Firat Ruschitzka, Frank Holzmeister, Johannes Hurlimann, David |
author_facet | Steffel, Jan Hurlimann, Anja Starck, Christoph Krasniqi, Nazmi Schmidt, Susann Luscher, Thomas F Duru, Firat Ruschitzka, Frank Holzmeister, Johannes Hurlimann, David |
author_sort | Steffel, Jan |
collection | PubMed |
description | BACKGROUND: Cardiac resynchronization therapy (CRT) has become an important pillar of contemporary heart failure therapy. The efficacy of CRT, however, critically relies on proper LV lead placement and performance, which is why data regarding the long-term performance of CS leads are of considerable interest. Available studies are limited by a restricted variety of lead vendors, earlier lead models and / or very short follow-up periods. In the current study, we therefore investigated the long-term performance of modern LV leads in a large "real world" cohort of patients undergoing CRT implantation. METHODS AND RESULTS: All 193 patients who had successfullyundergone CRT implantation at the University Hospital Zurich between September 2003 and January 2010 were included in the study. An overall stable course of stimulation energy was observed over time; neither ischemic etiology, lead configuration, or severely reduced EF had an influence on the evolution of energy thresholds over time. Interestingly, patients with a high energy threshold at baseline experienced a significant reduction during follow-up. In contrast, a significant drop in impedance was seen following implantation, followed by a steady course for the rest of the observation period. Only 15 patients (9.7%) showed an impedance > 1000 Ohm at any time during their follow-up. Seven lead dislocations were observed during follow up. CONCLUSION: The current comprehensive analysis of long-term performance of modern coronary sinus leads demonstrates excellent stability, performance and safety. These data may have important implications for physicians involved in biventricular pacemaker implantations and in the follow-up care of these patients. |
format | Online Article Text |
id | pubmed-4032778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Indian Heart Rhythm Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-40327782014-06-19 Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy Steffel, Jan Hurlimann, Anja Starck, Christoph Krasniqi, Nazmi Schmidt, Susann Luscher, Thomas F Duru, Firat Ruschitzka, Frank Holzmeister, Johannes Hurlimann, David Indian Pacing Electrophysiol J Original Article BACKGROUND: Cardiac resynchronization therapy (CRT) has become an important pillar of contemporary heart failure therapy. The efficacy of CRT, however, critically relies on proper LV lead placement and performance, which is why data regarding the long-term performance of CS leads are of considerable interest. Available studies are limited by a restricted variety of lead vendors, earlier lead models and / or very short follow-up periods. In the current study, we therefore investigated the long-term performance of modern LV leads in a large "real world" cohort of patients undergoing CRT implantation. METHODS AND RESULTS: All 193 patients who had successfullyundergone CRT implantation at the University Hospital Zurich between September 2003 and January 2010 were included in the study. An overall stable course of stimulation energy was observed over time; neither ischemic etiology, lead configuration, or severely reduced EF had an influence on the evolution of energy thresholds over time. Interestingly, patients with a high energy threshold at baseline experienced a significant reduction during follow-up. In contrast, a significant drop in impedance was seen following implantation, followed by a steady course for the rest of the observation period. Only 15 patients (9.7%) showed an impedance > 1000 Ohm at any time during their follow-up. Seven lead dislocations were observed during follow up. CONCLUSION: The current comprehensive analysis of long-term performance of modern coronary sinus leads demonstrates excellent stability, performance and safety. These data may have important implications for physicians involved in biventricular pacemaker implantations and in the follow-up care of these patients. Indian Heart Rhythm Society 2014-05-25 /pmc/articles/PMC4032778/ /pubmed/24948850 Text en Copyright: © 2014 Steffel et al. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Steffel, Jan Hurlimann, Anja Starck, Christoph Krasniqi, Nazmi Schmidt, Susann Luscher, Thomas F Duru, Firat Ruschitzka, Frank Holzmeister, Johannes Hurlimann, David Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title | Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title_full | Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title_fullStr | Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title_full_unstemmed | Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title_short | Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy |
title_sort | long-term performance of modern coronary sinus leads in cardiac resynchronization therapy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4032778/ https://www.ncbi.nlm.nih.gov/pubmed/24948850 |
work_keys_str_mv | AT steffeljan longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT hurlimannanja longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT starckchristoph longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT krasniqinazmi longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT schmidtsusann longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT luscherthomasf longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT durufirat longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT ruschitzkafrank longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT holzmeisterjohannes longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy AT hurlimanndavid longtermperformanceofmoderncoronarysinusleadsincardiacresynchronizationtherapy |