Cargando…

Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience

BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recentl...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiu, Albert Ho Yuen, Aw, Grace, Wenderoth, Jason David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4033141/
https://www.ncbi.nlm.nih.gov/pubmed/23749795
http://dx.doi.org/10.1136/neurintsurg-2013-010768
_version_ 1782317771884855296
author Chiu, Albert Ho Yuen
Aw, Grace
Wenderoth, Jason David
author_facet Chiu, Albert Ho Yuen
Aw, Grace
Wenderoth, Jason David
author_sort Chiu, Albert Ho Yuen
collection PubMed
description BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recently, endovascular embolization has become the first-line treatment. The liquid embolic agent Onyx (ethyl vinyl copolymer) has become the agent of choice, but problems with reflux around the delivery microcatheter and inadvertent venous penetration have arisen. METHODS AND RESULTS: We present six cases in which the double-lumen balloon microcatheter was used to transarterially embolize dural arteriovenous fistulas via injection of Onyx through the wire lumen. Depending on the individual pathology a venous balloon was also used in some cases. The advantages and disadvantages of the use of these devices are discussed. CONCLUSIONS: We consider that the use of the double-lumen balloon technique for fistula embolization has the potential for reducing overall procedural times, procedural failures and catheter retention in certain situations. In such cases we would advocate this as a first-line technique. When lower profile, more navigable balloon catheters become available, this may become the standard of care.
format Online
Article
Text
id pubmed-4033141
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-40331412014-06-05 Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience Chiu, Albert Ho Yuen Aw, Grace Wenderoth, Jason David J Neurointerv Surg New Devices BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recently, endovascular embolization has become the first-line treatment. The liquid embolic agent Onyx (ethyl vinyl copolymer) has become the agent of choice, but problems with reflux around the delivery microcatheter and inadvertent venous penetration have arisen. METHODS AND RESULTS: We present six cases in which the double-lumen balloon microcatheter was used to transarterially embolize dural arteriovenous fistulas via injection of Onyx through the wire lumen. Depending on the individual pathology a venous balloon was also used in some cases. The advantages and disadvantages of the use of these devices are discussed. CONCLUSIONS: We consider that the use of the double-lumen balloon technique for fistula embolization has the potential for reducing overall procedural times, procedural failures and catheter retention in certain situations. In such cases we would advocate this as a first-line technique. When lower profile, more navigable balloon catheters become available, this may become the standard of care. BMJ Publishing Group 2014-06 2013-06-08 /pmc/articles/PMC4033141/ /pubmed/23749795 http://dx.doi.org/10.1136/neurintsurg-2013-010768 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/3.0/
spellingShingle New Devices
Chiu, Albert Ho Yuen
Aw, Grace
Wenderoth, Jason David
Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title_full Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title_fullStr Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title_full_unstemmed Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title_short Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
title_sort double-lumen arterial balloon catheter technique for onyx embolization of dural arteriovenous fistulas: initial experience
topic New Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4033141/
https://www.ncbi.nlm.nih.gov/pubmed/23749795
http://dx.doi.org/10.1136/neurintsurg-2013-010768
work_keys_str_mv AT chiualberthoyuen doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience
AT awgrace doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience
AT wenderothjasondavid doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience