Cargando…
Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience
BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recentl...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4033141/ https://www.ncbi.nlm.nih.gov/pubmed/23749795 http://dx.doi.org/10.1136/neurintsurg-2013-010768 |
_version_ | 1782317771884855296 |
---|---|
author | Chiu, Albert Ho Yuen Aw, Grace Wenderoth, Jason David |
author_facet | Chiu, Albert Ho Yuen Aw, Grace Wenderoth, Jason David |
author_sort | Chiu, Albert Ho Yuen |
collection | PubMed |
description | BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recently, endovascular embolization has become the first-line treatment. The liquid embolic agent Onyx (ethyl vinyl copolymer) has become the agent of choice, but problems with reflux around the delivery microcatheter and inadvertent venous penetration have arisen. METHODS AND RESULTS: We present six cases in which the double-lumen balloon microcatheter was used to transarterially embolize dural arteriovenous fistulas via injection of Onyx through the wire lumen. Depending on the individual pathology a venous balloon was also used in some cases. The advantages and disadvantages of the use of these devices are discussed. CONCLUSIONS: We consider that the use of the double-lumen balloon technique for fistula embolization has the potential for reducing overall procedural times, procedural failures and catheter retention in certain situations. In such cases we would advocate this as a first-line technique. When lower profile, more navigable balloon catheters become available, this may become the standard of care. |
format | Online Article Text |
id | pubmed-4033141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-40331412014-06-05 Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience Chiu, Albert Ho Yuen Aw, Grace Wenderoth, Jason David J Neurointerv Surg New Devices BACKGROUND: Dural arteriovenous fistulas are vascular malformations with variable clinical symptoms that range in severity from completely asymptomatic to seizures, dementia, loss of vision and intracranial hemorrhage. Historically, surgical obliteration was the treatment of choice but, more recently, endovascular embolization has become the first-line treatment. The liquid embolic agent Onyx (ethyl vinyl copolymer) has become the agent of choice, but problems with reflux around the delivery microcatheter and inadvertent venous penetration have arisen. METHODS AND RESULTS: We present six cases in which the double-lumen balloon microcatheter was used to transarterially embolize dural arteriovenous fistulas via injection of Onyx through the wire lumen. Depending on the individual pathology a venous balloon was also used in some cases. The advantages and disadvantages of the use of these devices are discussed. CONCLUSIONS: We consider that the use of the double-lumen balloon technique for fistula embolization has the potential for reducing overall procedural times, procedural failures and catheter retention in certain situations. In such cases we would advocate this as a first-line technique. When lower profile, more navigable balloon catheters become available, this may become the standard of care. BMJ Publishing Group 2014-06 2013-06-08 /pmc/articles/PMC4033141/ /pubmed/23749795 http://dx.doi.org/10.1136/neurintsurg-2013-010768 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | New Devices Chiu, Albert Ho Yuen Aw, Grace Wenderoth, Jason David Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title | Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title_full | Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title_fullStr | Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title_full_unstemmed | Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title_short | Double-lumen arterial balloon catheter technique for Onyx embolization of dural arteriovenous fistulas: initial experience |
title_sort | double-lumen arterial balloon catheter technique for onyx embolization of dural arteriovenous fistulas: initial experience |
topic | New Devices |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4033141/ https://www.ncbi.nlm.nih.gov/pubmed/23749795 http://dx.doi.org/10.1136/neurintsurg-2013-010768 |
work_keys_str_mv | AT chiualberthoyuen doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience AT awgrace doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience AT wenderothjasondavid doublelumenarterialballooncathetertechniqueforonyxembolizationofduralarteriovenousfistulasinitialexperience |