Cargando…
Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces
Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurren...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4035289/ https://www.ncbi.nlm.nih.gov/pubmed/24866262 http://dx.doi.org/10.1371/journal.pone.0098395 |
_version_ | 1782318039907172352 |
---|---|
author | Cole, Michael H. van den Hoorn, Wolbert Kavanagh, Justin K. Morrison, Steven Hodges, Paul W. Smeathers, James E. Kerr, Graham K. |
author_facet | Cole, Michael H. van den Hoorn, Wolbert Kavanagh, Justin K. Morrison, Steven Hodges, Paul W. Smeathers, James E. Kerr, Graham K. |
author_sort | Cole, Michael H. |
collection | PubMed |
description | Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations; i) subtraction of the best linear fit from the data (detrending); and ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s(−2)). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s(−2)), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s(−2)). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments. |
format | Online Article Text |
id | pubmed-4035289 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40352892014-06-02 Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces Cole, Michael H. van den Hoorn, Wolbert Kavanagh, Justin K. Morrison, Steven Hodges, Paul W. Smeathers, James E. Kerr, Graham K. PLoS One Research Article Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations; i) subtraction of the best linear fit from the data (detrending); and ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s(−2)). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s(−2)), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s(−2)). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments. Public Library of Science 2014-05-27 /pmc/articles/PMC4035289/ /pubmed/24866262 http://dx.doi.org/10.1371/journal.pone.0098395 Text en © 2014 Cole et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Cole, Michael H. van den Hoorn, Wolbert Kavanagh, Justin K. Morrison, Steven Hodges, Paul W. Smeathers, James E. Kerr, Graham K. Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title | Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title_full | Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title_fullStr | Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title_full_unstemmed | Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title_short | Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces |
title_sort | concurrent validity of accelerations measured using a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4035289/ https://www.ncbi.nlm.nih.gov/pubmed/24866262 http://dx.doi.org/10.1371/journal.pone.0098395 |
work_keys_str_mv | AT colemichaelh concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT vandenhoornwolbert concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT kavanaghjustink concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT morrisonsteven concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT hodgespaulw concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT smeathersjamese concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces AT kerrgrahamk concurrentvalidityofaccelerationsmeasuredusingatriaxialinertialmeasurementunitwhilewalkingonfirmcompliantandunevensurfaces |