Cargando…

Evaluation of EMG, force and joystick as control interfaces for active arm supports

BACKGROUND: The performance capabilities and limitations of control interfaces for the operation of active movement-assistive devices remain unclear. Selecting an optimal interface for an application requires a thorough understanding of the performance of multiple control interfaces. METHODS: In thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lobo-Prat, Joan, Keemink, Arvid QL, Stienen, Arno HA, Schouten, Alfred C, Veltink4, Peter H, Koopman, Bart FJM
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041061/
https://www.ncbi.nlm.nih.gov/pubmed/24746015
http://dx.doi.org/10.1186/1743-0003-11-68
_version_ 1782318631571423232
author Lobo-Prat, Joan
Keemink, Arvid QL
Stienen, Arno HA
Schouten, Alfred C
Veltink4, Peter H
Koopman, Bart FJM
author_facet Lobo-Prat, Joan
Keemink, Arvid QL
Stienen, Arno HA
Schouten, Alfred C
Veltink4, Peter H
Koopman, Bart FJM
author_sort Lobo-Prat, Joan
collection PubMed
description BACKGROUND: The performance capabilities and limitations of control interfaces for the operation of active movement-assistive devices remain unclear. Selecting an optimal interface for an application requires a thorough understanding of the performance of multiple control interfaces. METHODS: In this study the performance of EMG-, force- and joystick-based control interfaces were assessed in healthy volunteers with a screen-based one-dimensional position-tracking task. The participants had to track a target that was moving according to a multisine signal with a bandwidth of 3 Hz. The velocity of the cursor was proportional to the interface signal. The performance of the control interfaces were evaluated in terms of tracking error, gain margin crossover frequency, information transmission rate and effort. RESULTS: None of the evaluated interfaces was superior in all four performance descriptors. The EMG-based interface was superior in tracking error and gain margin crossover frequency compared to the force- and the joystick-based interfaces. The force-based interface provided higher information transmission rate and lower effort than the EMG-based interface. The joystick-based interface did not present any significant difference with the force-based interface for any of the four performance descriptors. We found that significant differences in terms of tracking error and information transmission rate were present beyond 0.9 and 1.4 Hz respectively. CONCLUSIONS: Despite the fact that the EMG-based interface is far from the natural way of interacting with the environment, while the force-based interface is closer, the EMG-based interface presented very similar and for some descriptors even a better performance than the force-based interface for frequencies below 1.4 Hz. The classical joystick presented a similar performance to the force-based interface and holds the advantage of being a well established interface for the control of many assistive devices. From these findings we concluded that all the control interfaces considered in this study can be regarded as a candidate interface for the control of an active arm support.
format Online
Article
Text
id pubmed-4041061
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-40410612014-06-16 Evaluation of EMG, force and joystick as control interfaces for active arm supports Lobo-Prat, Joan Keemink, Arvid QL Stienen, Arno HA Schouten, Alfred C Veltink4, Peter H Koopman, Bart FJM J Neuroeng Rehabil Research BACKGROUND: The performance capabilities and limitations of control interfaces for the operation of active movement-assistive devices remain unclear. Selecting an optimal interface for an application requires a thorough understanding of the performance of multiple control interfaces. METHODS: In this study the performance of EMG-, force- and joystick-based control interfaces were assessed in healthy volunteers with a screen-based one-dimensional position-tracking task. The participants had to track a target that was moving according to a multisine signal with a bandwidth of 3 Hz. The velocity of the cursor was proportional to the interface signal. The performance of the control interfaces were evaluated in terms of tracking error, gain margin crossover frequency, information transmission rate and effort. RESULTS: None of the evaluated interfaces was superior in all four performance descriptors. The EMG-based interface was superior in tracking error and gain margin crossover frequency compared to the force- and the joystick-based interfaces. The force-based interface provided higher information transmission rate and lower effort than the EMG-based interface. The joystick-based interface did not present any significant difference with the force-based interface for any of the four performance descriptors. We found that significant differences in terms of tracking error and information transmission rate were present beyond 0.9 and 1.4 Hz respectively. CONCLUSIONS: Despite the fact that the EMG-based interface is far from the natural way of interacting with the environment, while the force-based interface is closer, the EMG-based interface presented very similar and for some descriptors even a better performance than the force-based interface for frequencies below 1.4 Hz. The classical joystick presented a similar performance to the force-based interface and holds the advantage of being a well established interface for the control of many assistive devices. From these findings we concluded that all the control interfaces considered in this study can be regarded as a candidate interface for the control of an active arm support. BioMed Central 2014-04-19 /pmc/articles/PMC4041061/ /pubmed/24746015 http://dx.doi.org/10.1186/1743-0003-11-68 Text en Copyright © 2014 Lobo-Prat et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Lobo-Prat, Joan
Keemink, Arvid QL
Stienen, Arno HA
Schouten, Alfred C
Veltink4, Peter H
Koopman, Bart FJM
Evaluation of EMG, force and joystick as control interfaces for active arm supports
title Evaluation of EMG, force and joystick as control interfaces for active arm supports
title_full Evaluation of EMG, force and joystick as control interfaces for active arm supports
title_fullStr Evaluation of EMG, force and joystick as control interfaces for active arm supports
title_full_unstemmed Evaluation of EMG, force and joystick as control interfaces for active arm supports
title_short Evaluation of EMG, force and joystick as control interfaces for active arm supports
title_sort evaluation of emg, force and joystick as control interfaces for active arm supports
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041061/
https://www.ncbi.nlm.nih.gov/pubmed/24746015
http://dx.doi.org/10.1186/1743-0003-11-68
work_keys_str_mv AT lobopratjoan evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports
AT keeminkarvidql evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports
AT stienenarnoha evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports
AT schoutenalfredc evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports
AT veltink4peterh evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports
AT koopmanbartfjm evaluationofemgforceandjoystickascontrolinterfacesforactivearmsupports