Cargando…

The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients

BACKGROUND: The usefulness of dynamic parameters derived by heart-lung interaction for fluid responsiveness in pediatric patients has been revealed. However, the effects of peak inspiratory pressure (PIP) that could affect the absolute values and the accuracy in pediatric patients have not been well...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Woon-Seok, Kim, Jae Yun, Woo, Nam Sik, Yoon, Tae Gyoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041954/
https://www.ncbi.nlm.nih.gov/pubmed/24910727
http://dx.doi.org/10.4097/kjae.2014.66.5.358
_version_ 1782318738832359424
author Kang, Woon-Seok
Kim, Jae Yun
Woo, Nam Sik
Yoon, Tae Gyoon
author_facet Kang, Woon-Seok
Kim, Jae Yun
Woo, Nam Sik
Yoon, Tae Gyoon
author_sort Kang, Woon-Seok
collection PubMed
description BACKGROUND: The usefulness of dynamic parameters derived by heart-lung interaction for fluid responsiveness in pediatric patients has been revealed. However, the effects of peak inspiratory pressure (PIP) that could affect the absolute values and the accuracy in pediatric patients have not been well established. METHODS: Participants were 30 pediatric patients who underwent ventricular septal defect repair. After completion of surgical procedure and sternum closure, mean arterial blood pressure, heart rate, central venous pressure, cardiac output, cardiac index and stroke volume variation (SVV) were measured at PIP 10 cmH(2)O (PIP10), at PIP 15 cmH(2)O (PIP15), at PIP 20 cmH(2)O (PIP20) and at PIP 25 cmH(2)O (PIP25). RESULTS: SVV at PIP15 was larger than that at PIP10 (13.7 ± 2.9% at PIP10 vs 14.7 ± 2.5% at PIP15, P < 0.001) and SVV at PIP20 was larger than that at PIP10 and PIP15 (13.7 ± 2.9% at PIP10 vs 15.4 ± 2.5% at PIP20, P < 0.001; 14.7 ± 2.5% at PIP15 vs 15.4 ± 2.5% at PIP20, P < 0.001) and SVV at PIP25 was larger than that at PIP10 and PIP15 and PIP20 (13.7 ± 2.9% at PIP10 vs 17.4 ± 2.4% at PIP25, P < 0.001; 14.7 ± 2.5% at PIP15 vs 17.4 ± 2.4% at PIP25, P < 0.001; 15.4 ± 2.5% at PIP20 vs 17.4 ± 2.4% at PIP25, P < 0.001). CONCLUSIONS: SVV is affected by different levels of PIP in same patient and under same volume status. This finding must be taken into consideration when SVV is used to predict fluid responsiveness in mechanically ventilated pediatric patients.
format Online
Article
Text
id pubmed-4041954
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-40419542014-06-08 The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients Kang, Woon-Seok Kim, Jae Yun Woo, Nam Sik Yoon, Tae Gyoon Korean J Anesthesiol Clinical Research Article BACKGROUND: The usefulness of dynamic parameters derived by heart-lung interaction for fluid responsiveness in pediatric patients has been revealed. However, the effects of peak inspiratory pressure (PIP) that could affect the absolute values and the accuracy in pediatric patients have not been well established. METHODS: Participants were 30 pediatric patients who underwent ventricular septal defect repair. After completion of surgical procedure and sternum closure, mean arterial blood pressure, heart rate, central venous pressure, cardiac output, cardiac index and stroke volume variation (SVV) were measured at PIP 10 cmH(2)O (PIP10), at PIP 15 cmH(2)O (PIP15), at PIP 20 cmH(2)O (PIP20) and at PIP 25 cmH(2)O (PIP25). RESULTS: SVV at PIP15 was larger than that at PIP10 (13.7 ± 2.9% at PIP10 vs 14.7 ± 2.5% at PIP15, P < 0.001) and SVV at PIP20 was larger than that at PIP10 and PIP15 (13.7 ± 2.9% at PIP10 vs 15.4 ± 2.5% at PIP20, P < 0.001; 14.7 ± 2.5% at PIP15 vs 15.4 ± 2.5% at PIP20, P < 0.001) and SVV at PIP25 was larger than that at PIP10 and PIP15 and PIP20 (13.7 ± 2.9% at PIP10 vs 17.4 ± 2.4% at PIP25, P < 0.001; 14.7 ± 2.5% at PIP15 vs 17.4 ± 2.4% at PIP25, P < 0.001; 15.4 ± 2.5% at PIP20 vs 17.4 ± 2.4% at PIP25, P < 0.001). CONCLUSIONS: SVV is affected by different levels of PIP in same patient and under same volume status. This finding must be taken into consideration when SVV is used to predict fluid responsiveness in mechanically ventilated pediatric patients. The Korean Society of Anesthesiologists 2014-05 2014-05-26 /pmc/articles/PMC4041954/ /pubmed/24910727 http://dx.doi.org/10.4097/kjae.2014.66.5.358 Text en Copyright © the Korean Society of Anesthesiologists, 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research Article
Kang, Woon-Seok
Kim, Jae Yun
Woo, Nam Sik
Yoon, Tae Gyoon
The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title_full The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title_fullStr The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title_full_unstemmed The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title_short The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
title_sort influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients
topic Clinical Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041954/
https://www.ncbi.nlm.nih.gov/pubmed/24910727
http://dx.doi.org/10.4097/kjae.2014.66.5.358
work_keys_str_mv AT kangwoonseok theinfluenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT kimjaeyun theinfluenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT woonamsik theinfluenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT yoontaegyoon theinfluenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT kangwoonseok influenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT kimjaeyun influenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT woonamsik influenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients
AT yoontaegyoon influenceofdifferentmechanicalventilatorsettingsofpeakinspiratorypressureonstrokevolumevariationinpediatriccardiacsurgerypatients