Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study

Purpose. Rotating hinge knee prostheses should provide a stable situation following reconstruction. We performed a biomechanical analysis to establish the association between design of the central rotational stem (peg) and implant's stability, in a theoretical setting. Methods. Six different ro...

Descripción completa

Detalles Bibliográficos
Autores principales: Friesenbichler, Joerg, Leithner, Andreas, Glehr, Mathias, Sadoghi, Patrick, Maurer-Ertl, Werner, Avian, Alexander, Windhager, Reinhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045358/
https://www.ncbi.nlm.nih.gov/pubmed/24967114
http://dx.doi.org/10.1155/2013/701693
_version_ 1782319305386360832
author Friesenbichler, Joerg
Leithner, Andreas
Glehr, Mathias
Sadoghi, Patrick
Maurer-Ertl, Werner
Avian, Alexander
Windhager, Reinhard
author_facet Friesenbichler, Joerg
Leithner, Andreas
Glehr, Mathias
Sadoghi, Patrick
Maurer-Ertl, Werner
Avian, Alexander
Windhager, Reinhard
author_sort Friesenbichler, Joerg
collection PubMed
description Purpose. Rotating hinge knee prostheses should provide a stable situation following reconstruction. We performed a biomechanical analysis to establish the association between design of the central rotational stem (peg) and implant's stability, in a theoretical setting. Methods. Six different rotating hinge designs were tested, and three observers performed two different measurements with a custom made biomechanical apparatus and laterally directed pressure. The aim was to assign the degree of tilting of the peg within the vertical post-in channel by extending the distraction as well as the maximum amount of distraction before the peg's dislocation. An intraclass-correlation coefficient (ICC) was calculated to determine the observer's reliability. Results. Implant designs with cylindrical pegs of different lengths were superior to implant designs with conical or other shaped pegs concerning stability and maximum amount of distraction before dislocation, showing steep rising distraction-angular displacement curves. The ICC at 15 mm and 25 mm of distraction revealed high interobserver reliability (P < 0.001). Conclusion. The biomechanical analysis showed that rotating hinge prostheses with long and cylindrical pegs have the highest stability at any given amount of distraction. Designs with shorter and markedly tapered pegs may become unstable under conditions of mild joint distraction which has to be proven in future in vivo investigations.
format Online
Article
Text
id pubmed-4045358
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40453582014-06-25 Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study Friesenbichler, Joerg Leithner, Andreas Glehr, Mathias Sadoghi, Patrick Maurer-Ertl, Werner Avian, Alexander Windhager, Reinhard ISRN Orthop Research Article Purpose. Rotating hinge knee prostheses should provide a stable situation following reconstruction. We performed a biomechanical analysis to establish the association between design of the central rotational stem (peg) and implant's stability, in a theoretical setting. Methods. Six different rotating hinge designs were tested, and three observers performed two different measurements with a custom made biomechanical apparatus and laterally directed pressure. The aim was to assign the degree of tilting of the peg within the vertical post-in channel by extending the distraction as well as the maximum amount of distraction before the peg's dislocation. An intraclass-correlation coefficient (ICC) was calculated to determine the observer's reliability. Results. Implant designs with cylindrical pegs of different lengths were superior to implant designs with conical or other shaped pegs concerning stability and maximum amount of distraction before dislocation, showing steep rising distraction-angular displacement curves. The ICC at 15 mm and 25 mm of distraction revealed high interobserver reliability (P < 0.001). Conclusion. The biomechanical analysis showed that rotating hinge prostheses with long and cylindrical pegs have the highest stability at any given amount of distraction. Designs with shorter and markedly tapered pegs may become unstable under conditions of mild joint distraction which has to be proven in future in vivo investigations. Hindawi Publishing Corporation 2013-07-18 /pmc/articles/PMC4045358/ /pubmed/24967114 http://dx.doi.org/10.1155/2013/701693 Text en Copyright © 2013 Joerg Friesenbichler et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Friesenbichler, Joerg
Leithner, Andreas
Glehr, Mathias
Sadoghi, Patrick
Maurer-Ertl, Werner
Avian, Alexander
Windhager, Reinhard
Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title_full Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title_fullStr Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title_full_unstemmed Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title_short Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study
title_sort evaluation of stability of rotating hinge knee prostheses: a biomechanical study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045358/
https://www.ncbi.nlm.nih.gov/pubmed/24967114
http://dx.doi.org/10.1155/2013/701693
work_keys_str_mv AT friesenbichlerjoerg evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT leithnerandreas evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT glehrmathias evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT sadoghipatrick evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT maurerertlwerner evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT avianalexander evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy
AT windhagerreinhard evaluationofstabilityofrotatinghingekneeprosthesesabiomechanicalstudy