Cargando…
Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study
Background. The objective of the present study was to compare mechanical strength and stability of the newly designed spacer plate with the gold standard plate for the treatment of medial knee joint osteoarthritis. Materials and Methods. Ten fourth-generation tibial bone composites underwent a media...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045360/ https://www.ncbi.nlm.nih.gov/pubmed/24959357 http://dx.doi.org/10.1155/2013/387620 |
_version_ | 1782319305835151360 |
---|---|
author | Maas, Stefan Diffo Kaze, Arnaud Dueck, Klaus Pape, Dietrich |
author_facet | Maas, Stefan Diffo Kaze, Arnaud Dueck, Klaus Pape, Dietrich |
author_sort | Maas, Stefan |
collection | PubMed |
description | Background. The objective of the present study was to compare mechanical strength and stability of the newly designed spacer plate with the gold standard plate for the treatment of medial knee joint osteoarthritis. Materials and Methods. Ten fourth-generation tibial bone composites underwent a medial open-wedge high tibial osteotomy (HTO) according to standard techniques, using five TomoFix plates and five Contour Lock plates. Static compression load to failure and load-controlled cyclical fatigue failure tests were performed. Forces and horizontal displacements were measured; plastic deformations and dynamic stiffness were determined. Results and Discussion. In all samples, rotation of the tibial head and fracture of the opposite cortex were observed. Behaviors of the specimens under static loading were comparable between groups. Cyclic testing revealed lateral significant higher stiffness until failure for the Contour Lock compared to the TomoFix plate. No visible implant failure was observed in any group. Conclusion. Considering the static analysis, both plates offered sufficient stability under physiologic loads of up to 3000 N. The Contour Lock plate-fixated specimens showed a higher stability during the cyclic testing, supposedly due to the wider distance between the fixation screws. |
format | Online Article Text |
id | pubmed-4045360 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40453602014-06-23 Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study Maas, Stefan Diffo Kaze, Arnaud Dueck, Klaus Pape, Dietrich ISRN Orthop Research Article Background. The objective of the present study was to compare mechanical strength and stability of the newly designed spacer plate with the gold standard plate for the treatment of medial knee joint osteoarthritis. Materials and Methods. Ten fourth-generation tibial bone composites underwent a medial open-wedge high tibial osteotomy (HTO) according to standard techniques, using five TomoFix plates and five Contour Lock plates. Static compression load to failure and load-controlled cyclical fatigue failure tests were performed. Forces and horizontal displacements were measured; plastic deformations and dynamic stiffness were determined. Results and Discussion. In all samples, rotation of the tibial head and fracture of the opposite cortex were observed. Behaviors of the specimens under static loading were comparable between groups. Cyclic testing revealed lateral significant higher stiffness until failure for the Contour Lock compared to the TomoFix plate. No visible implant failure was observed in any group. Conclusion. Considering the static analysis, both plates offered sufficient stability under physiologic loads of up to 3000 N. The Contour Lock plate-fixated specimens showed a higher stability during the cyclic testing, supposedly due to the wider distance between the fixation screws. Hindawi Publishing Corporation 2013-09-23 /pmc/articles/PMC4045360/ /pubmed/24959357 http://dx.doi.org/10.1155/2013/387620 Text en Copyright © 2013 Stefan Maas et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Maas, Stefan Diffo Kaze, Arnaud Dueck, Klaus Pape, Dietrich Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title | Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title_full | Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title_fullStr | Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title_full_unstemmed | Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title_short | Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study |
title_sort | static and dynamic differences in fixation stability between a spacer plate and a small stature plate fixator used for high tibial osteotomies: a biomechanical bone composite study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045360/ https://www.ncbi.nlm.nih.gov/pubmed/24959357 http://dx.doi.org/10.1155/2013/387620 |
work_keys_str_mv | AT maasstefan staticanddynamicdifferencesinfixationstabilitybetweenaspacerplateandasmallstatureplatefixatorusedforhightibialosteotomiesabiomechanicalbonecompositestudy AT diffokazearnaud staticanddynamicdifferencesinfixationstabilitybetweenaspacerplateandasmallstatureplatefixatorusedforhightibialosteotomiesabiomechanicalbonecompositestudy AT dueckklaus staticanddynamicdifferencesinfixationstabilitybetweenaspacerplateandasmallstatureplatefixatorusedforhightibialosteotomiesabiomechanicalbonecompositestudy AT papedietrich staticanddynamicdifferencesinfixationstabilitybetweenaspacerplateandasmallstatureplatefixatorusedforhightibialosteotomiesabiomechanicalbonecompositestudy |